Skip to main content
Window · Vinyl Frame NFRC ASO · Product Line ASO-A-119

Associated Materials, Inc. — 1901/1921/1931 Double Hung · Double Hung

EPA ENERGY STAR Version 7.0 certifies 2,062 variants inside Associated Materials, Inc. 1901/1921/1931 Double Hung, combining Vinyl frame construction with U-Factors spanning 0.24 to 0.32 and SHGC 0.10 to 0.51. Qualifying for Northern, North-Central, South-Central, Southern, this Double Hung family places #1,034 of 1,352 among 1,352 Window families and posts 0.05 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.24
SHGC Range
0.10-0.51
Certified Options
2,062
Category Standing
#1,034 of 1,352

How does Associated Materials, Inc. 1901/1921/1931 Double Hung compare thermally against Window peers?

Associated Materials, Inc. 1901/1921/1931 Double Hung achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 1901/1921/1931 Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 1901/1921/1931 Double Hung (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

1901/1921/1931 Double Hung Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 34 certified Associated Materials, Inc. series, this Double Hung offers a 0.08 U-Factor adjustment span between 0.32 entry options and 0.24 top-performing glazing. Category standing is #1,034/1,352 (tied with 139 others at 0.24, more insulating than 13.2% of Window lines).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 77 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2024-02-15. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.24 conducts 144.0 BTU/hr (+12.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,062 certified glazing combinations for 1901/1921/1931 Double Hung (NFRC ASO) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 77 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 296 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 542 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 1,845 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Associated Materials, Inc. produce?

Compare other active Associated Materials, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Associated Materials, Inc. 1901/1921/1931 Double Hung appear below.

How efficient is Associated Materials, Inc. 1901/1921/1931 Double Hung compared with peer Window models?

EPA ENERGY STAR v7.0 records 2,062 configurations for Associated Materials, Inc. 1901/1921/1931 Double Hung covering Northern, North-Central, South-Central, Southern, dropping down to U 0.24 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Does Associated Materials, Inc. 1901/1921/1931 Double Hung qualify for the ENERGY STAR Northern Zone?

With a 0.24 minimum U-Factor, Associated Materials, Inc. 1901/1921/1931 Double Hung cannot satisfy prescriptive <= 0.22 Northern targets, yet 77 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

What BTU/hr heat transfer results from 1901/1921/1931 Double Hung's 0.24 minimum U-Factor?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 144.0 BTU/hr on 1901/1921/1931 Double Hung's lowest-U package (0.24), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

Which situations make 1901/1921/1931 Double Hung the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 1901/1921/1931 Double Hung options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Does 1901/1921/1931 Double Hung meet Southern hot-climate SHGC caps (<= 0.23)?

Exactly 1,845 1901/1921/1931 Double Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.10 rather than higher 0.51 glass.

How many Associated Materials, Inc. 1901/1921/1931 Double Hung variants earn ENERGY STAR Most Efficient?

1901/1921/1931 Double Hung holds zero Most Efficient entries across its 2,062 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

How do the 25C sunset and pre-1978 Lead RRP rules affect 1901/1921/1931 Double Hung?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Associated Materials, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

What permanent glass etch marks verify 1901/1921/1931 Double Hung after sticker removal?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code ASO and product line ASO-A-119, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Associated Materials, Inc. 1901/1921/1931 Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros