Window · Vinyl Frame NFRC ASO · Product Line ASO-A-103 ENERGY STAR Most Efficient Eligible

Associated Materials, Inc. — A581/S581/A592 Single Hung · Single Hung

Associated Materials, Inc. engineered the A581/S581/A592 Single Hung Single Hung line for Northern, North-Central, South-Central, Southern, certifying 14,368 glass-spacer combinations from 0.16 to 0.32 U-Factor and 0.06 to 0.50 SHGC. Relative to other Vinyl models tracked under NFRC ASO, its minimum U-Factor is 0.03 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.16
SHGC Range
0.06-0.50
Certified Options
14,368
Category Standing
#250 of 1,352

How does Associated Materials, Inc. A581/S581/A592 Single Hung compare thermally against Window peers?

Associated Materials, Inc. A581/S581/A592 Single Hung achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. A581/S581/A592 Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing A581/S581/A592 Single Hung (U 0.16).249<=0.153140.16-0.18This model: U 0.162670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

A581/S581/A592 Single Hung Cohort StandingMin U-Factor 0.16 stands at rank #250 of 1,352, outperforming 73.3% of peers.Min U-Factor 0.16Rank #250 of 1,352 (73.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), A581/S581/A592 Single Hung is 0.04 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.16-0.32.

Regional qualification covers Northern, North-Central, South-Central, Southern. 3,112 configurations meet ENERGY STAR Most Efficient criteria while 2,867 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.16 U-Factor yields 96.0 BTU/hr transfer (-36.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-01-19 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 14,368 certified glazing combinations for A581/S581/A592 Single Hung (NFRC ASO) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 2,867 packages (1,385 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 6,549 packages (2,259 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 6,897 packages (1,520 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 12,137 packages (2,373 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
JELD-WEN, inc. — JWC 6500 Vinyl Lift Out Horizontal Slider Vinyl 0.16 0.12 14,407
JELD-WEN, inc. — JWC 6500 Vinyl Single Hung Vinyl 0.16 0.12 14,484
Harvey Industries, Inc. — Vinyl Casement Window Vinyl 0.16 0.15 12,695
Ply Gem Window Group — Ply Gem 1500 Picture Window Vinyl 0.16 0.13 16,113
Harvey Industries, Inc. — Vinyl Awning Window Vinyl 0.16 0.15 12,087

What other certified series does Associated Materials, Inc. produce?

Compare other active Associated Materials, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Associated Materials, Inc. A581/S581/A592 Single Hung appear below.

How well does A581/S581/A592 Single Hung by Associated Materials, Inc. insulate relative to Window benchmarks?

Testing puts Associated Materials, Inc. A581/S581/A592 Single Hung at rank #250 of 1,352 Window entries with U 0.16 to 0.32 across 14,368 configurations. Solar heat gain ranges between 0.06 and 0.50 across Northern, North-Central, South-Central, Southern.

How does Associated Materials, Inc. A581/S581/A592 Single Hung satisfy Version 7.0 Northern criteria?

Yes, 2,867 packages satisfy Northern ENERGY STAR Version 7.0 rules in A581/S581/A592 Single Hung. Pairing multi-pane insulation down to 0.16 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How does a 3x5 ft A581/S581/A592 Single Hung window perform under a 40 deg F temperature drop?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 96.0 BTU/hr on A581/S581/A592 Single Hung's lowest-U package (0.16), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

What homeowner profiles are a poor match for Associated Materials, Inc. A581/S581/A592 Single Hung?

Do not specify A581/S581/A592 Single Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on A581/S581/A592 Single Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Is A581/S581/A592 Single Hung suitable for sunbelt cooling-dominated homes?

Exactly 12,137 A581/S581/A592 Single Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.06 rather than higher 0.50 glass.

Does A581/S581/A592 Single Hung carry EPA Most Efficient certification across its lineup?

EPA lists 3,112 Most Efficient options (21.7% share) inside Associated Materials, Inc. A581/S581/A592 Single Hung, out of 14,368 total Version 7.0 entries.

What federal compliance checks govern 2026 A581/S581/A592 Single Hung window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

What permanent glass etch marks verify A581/S581/A592 Single Hung after sticker removal?

Confirm both the paper NFRC label and permanent corner glass etch match line ASO-A-103 and NFRC ID ASO before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Associated Materials, Inc. A581/S581/A592 Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)