Skip to main content
Window · Aluminum Frame NFRC DRU · Product Line DRU-K-26 ENERGY STAR Most Efficient Eligible

DRUTEX S.A. — IGLO Energy Alucover Awning Window · Awning (Projected)

Across 40 DRUTEX S.A. certified families, IGLO Energy Alucover Awning Window supplies 10 Awning, Projected configurations starting at 0.18 U-Factor and 0.14 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.21 U-Factor and 0.26 SHGC. Its thermal floor ranks #477 of 1,352 category entries—0.02 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.18
SHGC Range
0.14-0.26
Certified Options
10
Category Standing
#477 of 1,352

How does DRUTEX S.A. IGLO Energy Alucover Awning Window compare thermally against Window peers?

DRUTEX S.A. IGLO Energy Alucover Awning Window achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. IGLO Energy Alucover Awning WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing IGLO Energy Alucover Awning Window (U 0.18).249<=0.153140.16-0.18This model: U 0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

IGLO Energy Alucover Awning Window Cohort StandingMin U-Factor 0.18 stands at rank #477 of 1,352, outperforming 58.4% of peers.Min U-Factor 0.18Rank #477 of 1,352 (58.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows DRUTEX S.A. IGLO Energy Alucover Awning Window standing at #477 of 1,352 certified Window product series, tied with 86 others at 0.18, more insulating than 58.4% of Window lines, top 41.6%. Comparing Aluminum profiles alone (median 0.23) shows -0.05 before selecting Low-E tiers.

Mapping NFRC SHGC values (0.14 to 0.26) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 8 configurations meet ENERGY STAR Most Efficient criteria while 7 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.18 U-Factor yields 108.0 BTU/hr transfer (-24.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2023-04-03 licensing and 2024-06-14 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 10 certified glazing combinations for IGLO Energy Alucover Awning Window (NFRC DRU) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 7 packages (5 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 10 packages (7 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 5 packages (4 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 5 packages (5 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does DRUTEX S.A. produce?

Compare other active DRUTEX S.A. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to DRUTEX S.A. IGLO Energy Alucover Awning Window appear below.

What thermal performance numbers separate DRUTEX S.A. IGLO Energy Alucover Awning Window from peers?

Testing puts DRUTEX S.A. IGLO Energy Alucover Awning Window at rank #477 of 1,352 Window entries with U 0.18 to 0.21 across 10 configurations. Solar heat gain ranges between 0.14 and 0.26 across Northern, North-Central, South-Central, Southern.

Is IGLO Energy Alucover Awning Window approved for Northern Zone heating climates?

Prescriptive Northern compliance covers 7 IGLO Energy Alucover Awning Window packages (U floor 0.18, SHGC >= 0.17). Because the complete series stretches up to U 0.21, specify the cold-climate glass code explicitly.

What BTU/hr heat transfer results from IGLO Energy Alucover Awning Window's 0.18 minimum U-Factor?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 108.0 BTU/hr on IGLO Energy Alucover Awning Window's lowest-U package (0.18), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.21 transfer proportionally more energy.

When should a buyer skip DRUTEX S.A. IGLO Energy Alucover Awning Window and compare alternatives?

Hot Southern owners needing SHGC <= 0.23 must avoid higher-solar IGLO Energy Alucover Awning Window options near 0.26 SHGC. Additionally, do not order Projected Awning (PRAW) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Can you install DRUTEX S.A. IGLO Energy Alucover Awning Window in Southern or South-Central zones?

Yes. 5 Southern-certified options inside DRUTEX S.A. IGLO Energy Alucover Awning Window satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.26 SHGC on west-facing glass to avoid excess afternoon solar gain.

Which package tier in IGLO Energy Alucover Awning Window holds Most Efficient recognition?

EPA lists 8 Most Efficient options (80.0% share) inside DRUTEX S.A. IGLO Energy Alucover Awning Window, out of 10 total Version 7.0 entries.

How do the 25C sunset and pre-1978 Lead RRP rules affect IGLO Energy Alucover Awning Window?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current IGLO Energy Alucover Awning Window retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

Where are NFRC and IGCC identification marks located on IGLO Energy Alucover Awning Window?

Match the NFRC thermal sticker for code DRU and line DRU-K-26 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for DRUTEX S.A. IGLO Energy Alucover Awning Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros