DRUTEX S.A. — IGLO Energy Alucover Casement Window · Casement Windows
With a minimum U-Factor of 0.18—-0.02 compared against the 0.20 Window median—DRUTEX S.A. IGLO Energy Alucover Casement Window spans 10 tested options across Northern, North-Central, South-Central, Southern up to 0.21 U-Factor. Carrying NFRC CPD code DRU, the Aluminum assembly includes 8 ENERGY STAR Most Efficient packages (80.0% of line) and offers SHGC packages between 0.14 and 0.26.
- Min U-Factor
- 0.18
- SHGC Range
- 0.14-0.26
- Certified Options
- 10
- Category Standing
- #477 of 1,352
How does DRUTEX S.A. IGLO Energy Alucover Casement Window compare thermally against Window peers?
DRUTEX S.A. IGLO Energy Alucover Casement Window achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows DRUTEX S.A. IGLO Energy Alucover Casement Window standing at #477 of 1,352 certified Window product series, tied with 86 others at 0.18, more insulating than 58.4% of Window lines, top 41.6%. Comparing Aluminum profiles alone (median 0.23) shows -0.05 before selecting Low-E tiers.
Regional qualification covers Northern, North-Central, South-Central, Southern. 8 configurations meet ENERGY STAR Most Efficient criteria while 7 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Data provenance links certification 2024-06-14 and FENSTAR license 2023-04-03 inside EPA Version 7.0 tables. Heat transfer computes to 108.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 10 certified glazing combinations for IGLO Energy Alucover Casement Window (NFRC DRU) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 7 packages (5 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 10 packages (7 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 5 packages (4 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 5 packages (5 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Vistaza Inc — Vi5 Series Fixed Window | Vinyl | 0.18 | 0.17 | 8 |
| KP Building Products Limited — 5100/6100/7100 Casement | Vinyl | 0.18 | 0.15 | 14 |
| KP Building Products Limited — 5110/6110/7110 Awning | Vinyl | 0.18 | 0.15 | 14 |
| Winchester Industries — Oxford / Bristol 751/251 Picture Window | Vinyl | 0.18 | 0.15 | 18 |
| Ideal Window Manufacturing — 1800 Casement | Vinyl | 0.18 | 0.17 | 26 |
What other certified series does DRUTEX S.A. produce?
Compare other active DRUTEX S.A. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
IGLO Energy Alucover Fixed Window
U-Factor 0.14–0.20 · 10 certified options.
IGLO ENERGY Classic Fixed Window
U-Factor 0.15–0.32 · 3,527 certified options.
IGLO ENERGY Tilt and Slide Door
U-Factor 0.15–0.28 · 2,993 certified options.
MB-79N/MB-86N SI Fixed Window
U-Factor 0.15–0.32 · 2,540 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to DRUTEX S.A. IGLO Energy Alucover Casement Window appear below.
What thermal performance numbers separate DRUTEX S.A. IGLO Energy Alucover Casement Window from peers?
Testing puts DRUTEX S.A. IGLO Energy Alucover Casement Window at rank #477 of 1,352 Window entries with U 0.18 to 0.21 across 10 configurations. Solar heat gain ranges between 0.14 and 0.26 across Northern, North-Central, South-Central, Southern.
Can homeowners install IGLO Energy Alucover Casement Window in cold Northern ENERGY STAR counties?
Cold-climate buyers get 7 compliant Northern packages inside IGLO Energy Alucover Casement Window, reaching down to U 0.18. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.21 options.
How much winter heat loss does IGLO Energy Alucover Casement Window conduct across a 15 sq ft opening?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.18 U-Factor yields 108.0 BTU/hr conductive transfer (-18.2% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
Which situations make IGLO Energy Alucover Casement Window the wrong window or door choice?
Skip IGLO Energy Alucover Casement Window if local historic preservation boards prohibit Aluminum profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Hot Southern owners needing SHGC <= 0.23 must avoid higher-solar IGLO Energy Alucover Casement Window options near 0.26 SHGC.
What Southern ENERGY STAR v7.0 options exist in IGLO Energy Alucover Casement Window?
Across Northern, North-Central, South-Central, Southern, 5 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside DRUTEX S.A. IGLO Energy Alucover Casement Window, while total line SHGC reaches 0.26 in colder packages.
Does IGLO Energy Alucover Casement Window carry EPA Most Efficient certification across its lineup?
Only 8 options out of 10 (80.0%) meet tighter Most Efficient U-Factor and SHGC thresholds in DRUTEX S.A. IGLO Energy Alucover Casement Window, usually requiring triple-pane or upgraded Low-E coatings.
How do the 25C sunset and pre-1978 Lead RRP rules affect IGLO Energy Alucover Casement Window?
IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 IGLO Energy Alucover Casement Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.
How do you cross-check NFRC DRU and product line DRU-K-25 on delivery?
Match the NFRC thermal sticker for code DRU and line DRU-K-25 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for DRUTEX S.A. IGLO Energy Alucover Casement Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)