Kohltech International, Ltd. — Supreme Double Glider · Double Slider
Kohltech International, Ltd. Supreme Double Glider is a Double Slider assembly with a Vinyl frame that reaches a minimum U-Factor of 0.17 across 18 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #362 of 1,352 in Window, its thermal floor is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.20 to 0.48.
- Min U-Factor
- 0.17
- SHGC Range
- 0.20-0.48
- Certified Options
- 18
- Category Standing
- #362 of 1,352
How does Kohltech International, Ltd. Supreme Double Glider compare thermally against Window peers?
Kohltech International, Ltd. Supreme Double Glider achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Relative to Window assemblies nationwide (median U 0.20), Supreme Double Glider is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.17-0.23.
Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 10 configurations meet ENERGY STAR Most Efficient criteria while 18 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Lifecycle documentation anchors KOI to 2025-02-10 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 102.0 BTU/hr conductive loss (-22.7% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 18 certified glazing combinations for Supreme Double Glider (NFRC KOI) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 18 packages (10 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 10 packages (6 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 4 packages (3 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 4 packages (3 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Seven D Windows and Door LLC — 7700/7800 Single Hung | Vinyl | 0.17 | 0.23 | 21 |
| Energex Window Alliance — Energex Casement Picture | Vinyl | 0.17 | 0.25 | 28 |
| KP Building Products Limited — 4020/5020/6020 Fixed Picture | Vinyl | 0.17 | 0.19 | 28 |
| KP Building Products Limited — 5120/6120/7120 Fixed Casement | Vinyl | 0.17 | 0.18 | 32 |
| Vinyl Window Designs, Ltd. — 800M Casement | Vinyl | 0.17 | 0.12 | 41 |
What other certified series does Kohltech International, Ltd. produce?
Compare other active Kohltech International, Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Fiberglass Entry Door
U-Factor 0.15–0.28 · 331,883 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kohltech International, Ltd. Supreme Double Glider appear below.
What thermal performance numbers separate Kohltech International, Ltd. Supreme Double Glider from peers?
EPA ENERGY STAR v7.0 records 18 configurations for Kohltech International, Ltd. Supreme Double Glider covering Northern, North-Central, South-Central, Southern, dropping down to U 0.17 versus a 0.20 Window median. Only 10 options earn Most Efficient status.
Can homeowners install Supreme Double Glider in cold Northern ENERGY STAR counties?
Yes. 18 packages in Kohltech International, Ltd. Supreme Double Glider clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.23.
What conductive BTU/hr difference separates Supreme Double Glider from the 0.22 Northern rule?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.17 U-Factor yields 102.0 BTU/hr conductive transfer (-22.7% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
Which situations make Supreme Double Glider the wrong window or door choice?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Supreme Double Glider options exceeding U 0.22. Additionally, do not order Dual-Slide Horizontal (HSXX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
How many Supreme Double Glider glazing packages pass Southern solar-heat rules?
Across Northern, North-Central, South-Central, Southern, 4 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Kohltech International, Ltd. Supreme Double Glider, while total line SHGC reaches 0.48 in colder packages.
How many Kohltech International, Ltd. Supreme Double Glider variants earn ENERGY STAR Most Efficient?
Only 10 options out of 18 (55.6%) meet tighter Most Efficient U-Factor and SHGC thresholds in Kohltech International, Ltd. Supreme Double Glider, usually requiring triple-pane or upgraded Low-E coatings.
How do the 25C sunset and pre-1978 Lead RRP rules affect Supreme Double Glider?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Supreme Double Glider retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
Where are NFRC and IGCC identification marks located on Supreme Double Glider?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code KOI and product line KOI-A-10, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Kohltech International, Ltd. Supreme Double Glider come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)