Skip to main content
Window · Wood Frame NFRC MAR · Product Line MAR-N-70

Marvin — Ultimate Wood Double Hung Picture 1 5/8 inch Sash · Picture Window

With a minimum U-Factor of 0.23—+0.03 compared against the 0.20 Window median—Marvin Ultimate Wood Double Hung Picture 1 5/8 inch Sash spans 1,700 tested options across North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code MAR, the Wood assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.11 and 0.30.

Min U-Factor
0.23
SHGC Range
0.11-0.30
Certified Options
1,700
Category Standing
#936 of 1,352

How does Marvin Ultimate Wood Double Hung Picture 1 5/8 inch Sash compare thermally against Window peers?

Marvin Ultimate Wood Double Hung Picture 1 5/8 inch Sash achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Ultimate Wood Double Hung Picture 1 5/8 inch SashHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Ultimate Wood Double Hung Picture 1 5/8 inch Sash (U 0.23).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.231460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Ultimate Wood Double Hung Picture 1 5/8 inch Sash Cohort StandingMin U-Factor 0.23 stands at rank #936 of 1,352, outperforming 23.6% of peers.Min U-Factor 0.23Rank #936 of 1,352 (23.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Wood cohort (0.21 median U-Factor), Ultimate Wood Double Hung Picture 1 5/8 inch Sash reaches 0.23 on its lowest-conductivity package — #246 of 408 in Wood, tied with 33 others at 0.23, more insulating than 31.6% of Wood lines (+0.02 vs Wood peers). Pairing NFRC ID MAR across multi-pane fills shifts U-Factor from 0.32 down toward 0.23.

Zone eligibility across EPA boundaries reaches 3 markets (North-Central, South-Central, Southern). Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.11 lowers cooling load.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.23 U-Factor yields 138.0 BTU/hr transfer (+6.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-03-05 licensing and 2024-08-08 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,700 certified glazing combinations for Ultimate Wood Double Hung Picture 1 5/8 inch Sash (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 514 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 987 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 1,458 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Ultimate Wood Double Hung Picture 1 5/8 inch Sash appear below.

Where does Marvin Ultimate Wood Double Hung Picture 1 5/8 inch Sash stand thermally among ENERGY STAR Window lines?

Testing puts Marvin Ultimate Wood Double Hung Picture 1 5/8 inch Sash at rank #936 of 1,352 Window entries with U 0.23 to 0.32 across 1,700 configurations. Solar heat gain ranges between 0.11 and 0.30 across North-Central, South-Central, Southern.

How does Marvin Ultimate Wood Double Hung Picture 1 5/8 inch Sash satisfy Version 7.0 Northern criteria?

No. Because Ultimate Wood Double Hung Picture 1 5/8 inch Sash reaches only 0.23 U-Factor with 0 Northern combinations, it is not approved for ENERGY STAR Northern counties. Specify this Wood line strictly across North-Central, South-Central, Southern cooling or mixed markets.

How do you calculate winter heat conduction for Marvin Ultimate Wood Double Hung Picture 1 5/8 inch Sash?

Using NFRC MAR U-Factor 0.23, a 15 sq ft Fixed Window (FIXD) assembly conducts 138.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+6.0 BTU/hr margin).

What homeowner profiles are a poor match for Marvin Ultimate Wood Double Hung Picture 1 5/8 inch Sash?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultimate Wood Double Hung Picture 1 5/8 inch Sash options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is Ultimate Wood Double Hung Picture 1 5/8 inch Sash suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 1,458 Southern-approved options within Ultimate Wood Double Hung Picture 1 5/8 inch Sash spanning SHGC down to 0.11. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Are all 1,700 Ultimate Wood Double Hung Picture 1 5/8 inch Sash configurations ENERGY STAR Most Efficient?

All 1,700 Ultimate Wood Double Hung Picture 1 5/8 inch Sash listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

How do the 25C sunset and pre-1978 Lead RRP rules affect Ultimate Wood Double Hung Picture 1 5/8 inch Sash?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Ultimate Wood Double Hung Picture 1 5/8 inch Sash retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

Where are NFRC and IGCC identification marks located on Ultimate Wood Double Hung Picture 1 5/8 inch Sash?

Match the NFRC thermal sticker for code MAR and line MAR-N-70 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Ultimate Wood Double Hung Picture 1 5/8 inch Sash come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)