Skip to main content
Window · Wood Frame NFRC AND · Product Line AND-N-65

Andersen Corporation — 400 Series Frenchwood® Patio Door Transom · Transom

EPA ENERGY STAR Version 7.0 certifies 1,676 variants inside Andersen Corporation 400 Series Frenchwood® Patio Door Transom, combining Wood frame construction with U-Factors spanning 0.23 to 0.32 and SHGC 0.10 to 0.32. Qualifying for North-Central, South-Central, Southern, this Transom family places #936 of 1,352 among 1,352 Window families and posts 0.02 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median among Wood peers.

Min U-Factor
0.23
SHGC Range
0.10-0.32
Certified Options
1,676
Category Standing
#936 of 1,352

How does Andersen Corporation 400 Series Frenchwood® Patio Door Transom compare thermally against Window peers?

Andersen Corporation 400 Series Frenchwood® Patio Door Transom achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 400 Series Frenchwood® Patio Door TransomHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 400 Series Frenchwood® Patio Door Transom (U 0.23).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.231460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

400 Series Frenchwood® Patio Door Transom Cohort StandingMin U-Factor 0.23 stands at rank #936 of 1,352, outperforming 23.6% of peers.Min U-Factor 0.23Rank #936 of 1,352 (23.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Andersen Corporation 400 Series Frenchwood® Patio Door Transom at rank #936 of 1,352 (tied with 97 others at 0.23, more insulating than 23.6% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.10-0.32 band.

Climate coverage for Andersen Corporation 400 Series Frenchwood® Patio Door Transom spans North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.10 lowers cooling load.

Data provenance links certification 2024-03-20 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 138.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,676 certified glazing combinations for 400 Series Frenchwood® Patio Door Transom (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 130 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 451 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 1,646 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 400 Series Frenchwood® Patio Door Transom appear below.

What U-Factor and SHGC range does Andersen Corporation 400 Series Frenchwood® Patio Door Transom achieve?

EPA ENERGY STAR v7.0 records 1,676 configurations for Andersen Corporation 400 Series Frenchwood® Patio Door Transom covering North-Central, South-Central, Southern, dropping down to U 0.23 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Which glazing options in Andersen Corporation 400 Series Frenchwood® Patio Door Transom meet Northern climate limits?

This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.23). Focus on North-Central, South-Central, Southern glazing applications where SHGC 0.10-0.32 manages cooling loads.

How much winter heat loss does 400 Series Frenchwood® Patio Door Transom conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.23 U-Factor yields 138.0 BTU/hr conductive transfer (+4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Who should NOT choose Andersen Corporation 400 Series Frenchwood® Patio Door Transom for a residential project?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Series Frenchwood® Patio Door Transom options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

Can you install Andersen Corporation 400 Series Frenchwood® Patio Door Transom in Southern or South-Central zones?

Warm-climate homeowners have 1,646 Southern-approved options within 400 Series Frenchwood® Patio Door Transom spanning SHGC down to 0.10. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

How many Andersen Corporation 400 Series Frenchwood® Patio Door Transom variants earn ENERGY STAR Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 1,676 400 Series Frenchwood® Patio Door Transom options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

What federal compliance checks govern 2026 400 Series Frenchwood® Patio Door Transom window swaps?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Andersen Corporation upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do you cross-check NFRC AND and product line AND-N-65 on delivery?

Match the NFRC thermal sticker for code AND and line AND-N-65 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 400 Series Frenchwood® Patio Door Transom come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)