Andersen Corporation — 200 Series Double-Hung Fixed/Specialty Windows · Picture Window
EPA ENERGY STAR Version 7.0 certifies 1,727 variants inside Andersen Corporation 200 Series Double-Hung Fixed/Specialty Windows, combining Wood frame construction with U-Factors spanning 0.23 to 0.32 and SHGC 0.14 to 0.49. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #936 of 1,352 among 1,352 Window families and posts 0.02 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median among Wood peers.
- Min U-Factor
- 0.23
- SHGC Range
- 0.14-0.49
- Certified Options
- 1,727
- Category Standing
- #936 of 1,352
How does Andersen Corporation 200 Series Double-Hung Fixed/Specialty Windows compare thermally against Window peers?
Andersen Corporation 200 Series Double-Hung Fixed/Specialty Windows achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 111 certified Andersen Corporation series, this Picture Window offers a 0.09 U-Factor adjustment span between 0.32 entry options and 0.23 top-performing glazing. Category standing is #936/1,352 (tied with 97 others at 0.23, more insulating than 23.6% of Window lines).
Climate coverage for Andersen Corporation 200 Series Double-Hung Fixed/Specialty Windows spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 115 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Lifecycle documentation anchors AND to 2024-04-09 certification (FENSTAR issued 2019-01-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 138.0 BTU/hr conductive loss (+4.5% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 1,727 certified glazing combinations for 200 Series Double-Hung Fixed/Specialty Windows (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 115 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 374 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 922 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 1,518 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Marvin — Ultimate Wood Double Hung Picture 1 5/8 inch Sash | Wood | 0.23 | 0.11 | 1,700 |
| Marvin — Ultimate Glider Picture | Wood | 0.23 | 0.11 | 2,132 |
| Windsor Windows and Doors — Legend Double Hung Transom | Wood | 0.23 | 0.10 | 777 |
| JELD-WEN, inc. — Custom Clad Casement | Wood | 0.23 | 0.11 | 774 |
| JELD-WEN, inc. — Custom Clad Casement In Sash Geometric | Wood | 0.23 | 0.11 | 745 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 200 Series Double-Hung Fixed/Specialty Windows appear below.
How well does 200 Series Double-Hung Fixed/Specialty Windows by Andersen Corporation insulate relative to Window benchmarks?
Testing puts Andersen Corporation 200 Series Double-Hung Fixed/Specialty Windows at rank #936 of 1,352 Window entries with U 0.23 to 0.32 across 1,727 configurations. Solar heat gain ranges between 0.14 and 0.49 across Northern, North-Central, South-Central, Southern.
Does Andersen Corporation 200 Series Double-Hung Fixed/Specialty Windows qualify for the ENERGY STAR Northern Zone?
Prescriptive Northern approval ends at U <= 0.22, above 200 Series Double-Hung Fixed/Specialty Windows's 0.23 minimum. However, 115 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.
How much winter heat loss does 200 Series Double-Hung Fixed/Specialty Windows conduct across a 15 sq ft opening?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 200 Series Double-Hung Fixed/Specialty Windows at U 0.23 conducts 138.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
What homeowner profiles are a poor match for Andersen Corporation 200 Series Double-Hung Fixed/Specialty Windows?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 200 Series Double-Hung Fixed/Specialty Windows options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
Can you install Andersen Corporation 200 Series Double-Hung Fixed/Specialty Windows in Southern or South-Central zones?
Exactly 1,518 200 Series Double-Hung Fixed/Specialty Windows options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.14 rather than higher 0.49 glass.
Are all 1,727 200 Series Double-Hung Fixed/Specialty Windows configurations ENERGY STAR Most Efficient?
All 1,727 200 Series Double-Hung Fixed/Specialty Windows listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.
What 2026 federal tax credit and Lead RRP rules apply to 200 Series Double-Hung Fixed/Specialty Windows?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 200 Series Double-Hung Fixed/Specialty Windows retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
How do you cross-check NFRC AND and product line AND-N-60 on delivery?
Inspectors match the temporary NFRC sticker (U 0.23-0.32, SHGC 0.14-0.49) against permit drawings for line AND-N-60. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 200 Series Double-Hung Fixed/Specialty Windows come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)