Skip to main content
Window · Wood Frame NFRC AND · Product Line AND-N-25

Andersen Corporation — 400 Series Specialty Windows - Springline® · Picture Window

EPA ENERGY STAR Version 7.0 certifies 1,657 variants inside Andersen Corporation 400 Series Specialty Windows - Springline®, combining Wood frame construction with U-Factors spanning 0.23 to 0.32 and SHGC 0.15 to 0.48. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #936 of 1,352 among 1,352 Window families and posts 0.02 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median among Wood peers.

Min U-Factor
0.23
SHGC Range
0.15-0.48
Certified Options
1,657
Category Standing
#936 of 1,352

How does Andersen Corporation 400 Series Specialty Windows - Springline® compare thermally against Window peers?

Andersen Corporation 400 Series Specialty Windows - Springline® achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 400 Series Specialty Windows - Springline®Histogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 400 Series Specialty Windows - Springline® (U 0.23).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.231460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

400 Series Specialty Windows - Springline® Cohort StandingMin U-Factor 0.23 stands at rank #936 of 1,352, outperforming 23.6% of peers.Min U-Factor 0.23Rank #936 of 1,352 (23.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Andersen Corporation 400 Series Specialty Windows - Springline® standing at #936 of 1,352 certified Window product series, tied with 97 others at 0.23, more insulating than 23.6% of Window lines. Comparing Wood profiles alone (median 0.21) shows +0.02 before selecting Low-E tiers.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 139 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors AND to 2024-04-09 certification (FENSTAR issued 2019-01-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 138.0 BTU/hr conductive loss (+4.5% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,657 certified glazing combinations for 400 Series Specialty Windows - Springline® (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 139 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 426 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 778 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 1,398 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 400 Series Specialty Windows - Springline® appear below.

How efficient is Andersen Corporation 400 Series Specialty Windows - Springline® compared with peer Window models?

Across 1,657 tested NFRC glazing configurations, Andersen Corporation 400 Series Specialty Windows - Springline® with Wood framing and Fixed Window (FIXD) style reaches a 0.23 minimum U-Factor and 0.15-0.48 SHGC band. It places #936 among 1,352 Window series—more insulating than 23.6%.

Is 400 Series Specialty Windows - Springline® approved for Northern Zone heating climates?

Northern qualification on 400 Series Specialty Windows - Springline® relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.23. Exactly 139 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.

How do you calculate winter heat conduction for Andersen Corporation 400 Series Specialty Windows - Springline®?

Using NFRC AND U-Factor 0.23, a 15 sq ft Fixed Window (FIXD) assembly conducts 138.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+6.0 BTU/hr margin).

Which situations make 400 Series Specialty Windows - Springline® the wrong window or door choice?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Series Specialty Windows - Springline® options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

How many 400 Series Specialty Windows - Springline® glazing packages pass Southern solar-heat rules?

Exactly 1,398 400 Series Specialty Windows - Springline® options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.15 rather than higher 0.48 glass.

Does 400 Series Specialty Windows - Springline® carry EPA Most Efficient certification across its lineup?

ENERGY STAR Most Efficient designation is absent across all 1,657 400 Series Specialty Windows - Springline® options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

How do the 25C sunset and pre-1978 Lead RRP rules affect 400 Series Specialty Windows - Springline®?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Andersen Corporation upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do building inspectors verify 400 Series Specialty Windows - Springline® glass specs on job sites?

Match the NFRC thermal sticker for code AND and line AND-N-25 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 400 Series Specialty Windows - Springline® come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros