Andersen Corporation — 400 Series Specialty Windows - Springline® · Picture Window
EPA ENERGY STAR Version 7.0 certifies 1,657 variants inside Andersen Corporation 400 Series Specialty Windows - Springline®, combining Wood frame construction with U-Factors spanning 0.23 to 0.32 and SHGC 0.15 to 0.48. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #936 of 1,352 among 1,352 Window families and posts 0.02 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median among Wood peers.
- Min U-Factor
- 0.23
- SHGC Range
- 0.15-0.48
- Certified Options
- 1,657
- Category Standing
- #936 of 1,352
How does Andersen Corporation 400 Series Specialty Windows - Springline® compare thermally against Window peers?
Andersen Corporation 400 Series Specialty Windows - Springline® achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows Andersen Corporation 400 Series Specialty Windows - Springline® standing at #936 of 1,352 certified Window product series, tied with 97 others at 0.23, more insulating than 23.6% of Window lines. Comparing Wood profiles alone (median 0.21) shows +0.02 before selecting Low-E tiers.
Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 139 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Lifecycle documentation anchors AND to 2024-04-09 certification (FENSTAR issued 2019-01-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 138.0 BTU/hr conductive loss (+4.5% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 1,657 certified glazing combinations for 400 Series Specialty Windows - Springline® (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 139 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 426 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 778 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 1,398 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Marvin — Ultimate Wood Double Hung Picture 1 5/8 inch Sash | Wood | 0.23 | 0.11 | 1,700 |
| Marvin — Ultimate Glider Picture | Wood | 0.23 | 0.11 | 2,132 |
| Windsor Windows and Doors — Legend Double Hung Transom | Wood | 0.23 | 0.10 | 777 |
| JELD-WEN, inc. — Custom Clad Casement | Wood | 0.23 | 0.11 | 774 |
| JELD-WEN, inc. — Custom Clad Casement In Sash Geometric | Wood | 0.23 | 0.11 | 745 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 400 Series Specialty Windows - Springline® appear below.
How efficient is Andersen Corporation 400 Series Specialty Windows - Springline® compared with peer Window models?
Across 1,657 tested NFRC glazing configurations, Andersen Corporation 400 Series Specialty Windows - Springline® with Wood framing and Fixed Window (FIXD) style reaches a 0.23 minimum U-Factor and 0.15-0.48 SHGC band. It places #936 among 1,352 Window series—more insulating than 23.6%.
Is 400 Series Specialty Windows - Springline® approved for Northern Zone heating climates?
Northern qualification on 400 Series Specialty Windows - Springline® relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.23. Exactly 139 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.
How do you calculate winter heat conduction for Andersen Corporation 400 Series Specialty Windows - Springline®?
Using NFRC AND U-Factor 0.23, a 15 sq ft Fixed Window (FIXD) assembly conducts 138.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+6.0 BTU/hr margin).
Which situations make 400 Series Specialty Windows - Springline® the wrong window or door choice?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Series Specialty Windows - Springline® options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.
How many 400 Series Specialty Windows - Springline® glazing packages pass Southern solar-heat rules?
Exactly 1,398 400 Series Specialty Windows - Springline® options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.15 rather than higher 0.48 glass.
Does 400 Series Specialty Windows - Springline® carry EPA Most Efficient certification across its lineup?
ENERGY STAR Most Efficient designation is absent across all 1,657 400 Series Specialty Windows - Springline® options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.
How do the 25C sunset and pre-1978 Lead RRP rules affect 400 Series Specialty Windows - Springline®?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 Andersen Corporation upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
How do building inspectors verify 400 Series Specialty Windows - Springline® glass specs on job sites?
Match the NFRC thermal sticker for code AND and line AND-N-25 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 400 Series Specialty Windows - Springline® come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)