Skip to main content
Window · Wood Frame NFRC MAR · Product Line MAR-N-407

Marvin — Ultimate Wood Outswing French Door Transom · Picture Window

Positioning #1,174/1,352 in certified Window, Marvin Ultimate Wood Outswing French Door Transom pairs Wood frame construction with 1,476 glazing options rated between 0.10 and 0.26 SHGC across North-Central, South-Central, Southern. Across 105 certified Marvin product families, its thermal resistance spans 0.25 to 0.32 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.25
SHGC Range
0.10-0.26
Certified Options
1,476
Category Standing
#1,174 of 1,352

How does Marvin Ultimate Wood Outswing French Door Transom compare thermally against Window peers?

Marvin Ultimate Wood Outswing French Door Transom achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Ultimate Wood Outswing French Door TransomHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Ultimate Wood Outswing French Door Transom (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Ultimate Wood Outswing French Door Transom Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Wood cohort (0.21 median U-Factor), Ultimate Wood Outswing French Door Transom reaches 0.25 on its lowest-conductivity package — #319 of 408 in Wood, tied with 32 others at 0.25, more insulating than 14.0% of Wood lines (+0.04 vs Wood peers). Pairing NFRC ID MAR across multi-pane fills shifts U-Factor from 0.32 down toward 0.25.

Mapping NFRC SHGC values (0.10 to 0.26) against ENERGY STAR Version 7.0 targets approves North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.10 lowers cooling load.

Lifecycle documentation anchors MAR to 2025-08-27 certification (FENSTAR issued 2019-03-05). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 150.0 BTU/hr conductive loss (+13.6% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,476 certified glazing combinations for Ultimate Wood Outswing French Door Transom (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 214 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 763 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 1,446 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Ultimate Wood Outswing French Door Transom appear below.

How efficient is Marvin Ultimate Wood Outswing French Door Transom compared with peer Window models?

Testing puts Marvin Ultimate Wood Outswing French Door Transom at rank #1,174 of 1,352 Window entries with U 0.25 to 0.32 across 1,476 configurations. Solar heat gain ranges between 0.10 and 0.26 across North-Central, South-Central, Southern.

How does Marvin Ultimate Wood Outswing French Door Transom satisfy Version 7.0 Northern criteria?

This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.25). Focus on North-Central, South-Central, Southern glazing applications where SHGC 0.10-0.26 manages cooling loads.

How does a 3x5 ft Ultimate Wood Outswing French Door Transom window perform under a 40 deg F temperature drop?

Using NFRC MAR U-Factor 0.25, a 15 sq ft Fixed Window (FIXD) assembly conducts 150.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+18.0 BTU/hr margin).

Which situations make Ultimate Wood Outswing French Door Transom the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultimate Wood Outswing French Door Transom options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

What Southern ENERGY STAR v7.0 options exist in Ultimate Wood Outswing French Door Transom?

Yes. 1,446 Southern-certified options inside Marvin Ultimate Wood Outswing French Door Transom satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.26 SHGC on west-facing glass to avoid excess afternoon solar gain.

Does Ultimate Wood Outswing French Door Transom carry EPA Most Efficient certification across its lineup?

ENERGY STAR Most Efficient designation is absent across all 1,476 Ultimate Wood Outswing French Door Transom options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

What federal compliance checks govern 2026 Ultimate Wood Outswing French Door Transom window swaps?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Marvin upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do you cross-check NFRC MAR and product line MAR-N-407 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line MAR-N-407 and NFRC ID MAR before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Ultimate Wood Outswing French Door Transom come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros