Skip to main content
Window · Wood Frame NFRC WIN · Product Line WIN-N-165

Windsor Windows and Doors — Revive Hybrid Pocket Double Hung · Double Hung

Windsor Windows and Doors Revive Hybrid Pocket Double Hung is a Double Hung assembly with a Wood frame that reaches a minimum U-Factor of 0.25 across 450 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #1,174 of 1,352 in Window, its thermal floor is 0.05 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.11 to 0.45.

Min U-Factor
0.25
SHGC Range
0.11-0.45
Certified Options
450
Category Standing
#1,174 of 1,352

How does Windsor Windows and Doors Revive Hybrid Pocket Double Hung compare thermally against Window peers?

Windsor Windows and Doors Revive Hybrid Pocket Double Hung achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Revive Hybrid Pocket Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Revive Hybrid Pocket Double Hung (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Revive Hybrid Pocket Double Hung Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Windsor Windows and Doors Revive Hybrid Pocket Double Hung at rank #1,174 of 1,352 (tied with 81 others at 0.25, more insulating than 7.2% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.11-0.45 band.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 6 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2025-11-25 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 150.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 450 certified glazing combinations for Revive Hybrid Pocket Double Hung (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 6 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 6 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 63 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 444 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Revive Hybrid Pocket Double Hung appear below.

How well does Revive Hybrid Pocket Double Hung by Windsor Windows and Doors insulate relative to Window benchmarks?

EPA ENERGY STAR v7.0 records 450 configurations for Windsor Windows and Doors Revive Hybrid Pocket Double Hung covering Northern, North-Central, South-Central, Southern, dropping down to U 0.25 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

How does Windsor Windows and Doors Revive Hybrid Pocket Double Hung satisfy Version 7.0 Northern criteria?

Northern qualification on Revive Hybrid Pocket Double Hung relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.25. Exactly 6 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.

What conductive BTU/hr difference separates Revive Hybrid Pocket Double Hung from the 0.22 Northern rule?

Using NFRC WIN U-Factor 0.25, a 15 sq ft Double-Hung (VSDH) assembly conducts 150.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+18.0 BTU/hr margin).

Which situations make Revive Hybrid Pocket Double Hung the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Revive Hybrid Pocket Double Hung options exceeding U 0.22. Additionally, do not order Double-Hung (VSDH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Does Revive Hybrid Pocket Double Hung meet Southern hot-climate SHGC caps (<= 0.23)?

Warm-climate homeowners have 444 Southern-approved options within Revive Hybrid Pocket Double Hung spanning SHGC down to 0.11. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

What glazing share inside Revive Hybrid Pocket Double Hung qualifies as Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 450 Revive Hybrid Pocket Double Hung options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

Do 2026 Revive Hybrid Pocket Double Hung installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Revive Hybrid Pocket Double Hung installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do building inspectors verify Revive Hybrid Pocket Double Hung glass specs on job sites?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code WIN and product line WIN-N-165, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Revive Hybrid Pocket Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros