Skip to main content
Window · Wood Frame NFRC AND · Product Line AND-N-151

Andersen Corporation — Complementary Clad French Casement Window · Casement Windows

Across 111 Andersen Corporation certified families, Complementary Clad French Casement Window supplies 2,165 Casement Windows configurations starting at 0.25 U-Factor and 0.12 SHGC for North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.35 SHGC. Its thermal floor ranks #1,174 of 1,352 category entries—0.05 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.25
SHGC Range
0.12-0.35
Certified Options
2,165
Category Standing
#1,174 of 1,352

How does Andersen Corporation Complementary Clad French Casement Window compare thermally against Window peers?

Andersen Corporation Complementary Clad French Casement Window achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Complementary Clad French Casement WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Complementary Clad French Casement Window (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Complementary Clad French Casement Window Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Wood cohort (0.21 median U-Factor), Complementary Clad French Casement Window reaches 0.25 on its lowest-conductivity package — #319 of 408 in Wood, tied with 32 others at 0.25, more insulating than 14.0% of Wood lines (+0.04 vs Wood peers). Pairing NFRC ID AND across multi-pane fills shifts U-Factor from 0.32 down toward 0.25.

Mapping NFRC SHGC values (0.12 to 0.35) against ENERGY STAR Version 7.0 targets approves North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.12 lowers cooling load.

Registry history records EPA FENSTAR licensing on 2019-01-08 and v7.0 data certification on 2024-04-18. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.25 conducts 150.0 BTU/hr (+18.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,165 certified glazing combinations for Complementary Clad French Casement Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 60 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 424 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 2,151 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation Complementary Clad French Casement Window appear below.

Where does Andersen Corporation Complementary Clad French Casement Window stand thermally among ENERGY STAR Window lines?

Built with Wood framing in Double-Vent Casement (CSDV) style, Andersen Corporation Complementary Clad French Casement Window offers 2,165 Version 7.0 configurations from U 0.25 up to 0.32, posting +0.05 against the Window median of 0.20 with 0 Most Efficient picks.

Which glazing options in Andersen Corporation Complementary Clad French Casement Window meet Northern climate limits?

No. Because Complementary Clad French Casement Window reaches only 0.25 U-Factor with 0 Northern combinations, it is not approved for ENERGY STAR Northern counties. Specify this Wood line strictly across North-Central, South-Central, Southern cooling or mixed markets.

What conductive BTU/hr difference separates Complementary Clad French Casement Window from the 0.22 Northern rule?

Using NFRC AND U-Factor 0.25, a 15 sq ft Double-Vent Casement (CSDV) assembly conducts 150.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+18.0 BTU/hr margin).

What homeowner profiles are a poor match for Andersen Corporation Complementary Clad French Casement Window?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Complementary Clad French Casement Window options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

Can you install Andersen Corporation Complementary Clad French Casement Window in Southern or South-Central zones?

Across North-Central, South-Central, Southern, 2,151 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Andersen Corporation Complementary Clad French Casement Window, while total line SHGC reaches 0.35 in colder packages.

How many Andersen Corporation Complementary Clad French Casement Window variants earn ENERGY STAR Most Efficient?

All 2,165 Complementary Clad French Casement Window listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

Do 2026 Complementary Clad French Casement Window installations qualify for IRS Section 25C tax credits?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do building inspectors verify Complementary Clad French Casement Window glass specs on job sites?

Verify NFRC ID AND and series AND-N-151 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation Complementary Clad French Casement Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros