Skip to main content
Window · Wood Frame NFRC JEL · Product Line JEL-N-885

JELD-WEN, inc. — Siteline Wood (W-5500) Double Hung · Double Hung

Positioning #1,174/1,352 in certified Window, JELD-WEN, inc. Siteline Wood (W-5500) Double Hung pairs Wood frame with Metal-Clad Wood / Wood sash with 2,985 glazing options rated between 0.11 and 0.46 SHGC across Northern, North-Central, South-Central, Southern. Across 61 certified JELD-WEN, inc. product families, its thermal resistance spans 0.25 to 0.32 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.25
SHGC Range
0.11-0.46
Certified Options
2,985
Category Standing
#1,174 of 1,352

How does JELD-WEN, inc. Siteline Wood (W-5500) Double Hung compare thermally against Window peers?

JELD-WEN, inc. Siteline Wood (W-5500) Double Hung achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Siteline Wood (W-5500) Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Siteline Wood (W-5500) Double Hung (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Siteline Wood (W-5500) Double Hung Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places JELD-WEN, inc. Siteline Wood (W-5500) Double Hung at rank #1,174 of 1,352 (tied with 81 others at 0.25, more insulating than 7.2% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.11-0.46 band.

Mapping NFRC SHGC values (0.11 to 0.46) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 42 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.25 U-Factor yields 150.0 BTU/hr transfer (+18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2026-01-09 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,985 certified glazing combinations for Siteline Wood (W-5500) Double Hung (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 42 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 50 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 421 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 2,943 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Siteline Wood (W-5500) Double Hung appear below.

How efficient is JELD-WEN, inc. Siteline Wood (W-5500) Double Hung compared with peer Window models?

JELD-WEN, inc. Siteline Wood (W-5500) Double Hung spans 2,985 certified configurations with U-Factors between 0.25 and 0.32 and SHGC values from 0.11 to 0.46. Ranked #1,174 of 1,352 Window families, it carries 0 Most Efficient options.

Is Siteline Wood (W-5500) Double Hung approved for Northern Zone heating climates?

With a 0.25 minimum U-Factor, JELD-WEN, inc. Siteline Wood (W-5500) Double Hung cannot satisfy prescriptive <= 0.22 Northern targets, yet 42 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

How does a 3x5 ft Siteline Wood (W-5500) Double Hung window perform under a 40 deg F temperature drop?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 150.0 BTU/hr on Siteline Wood (W-5500) Double Hung's lowest-U package (0.25), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

When should a buyer skip JELD-WEN, inc. Siteline Wood (W-5500) Double Hung and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Siteline Wood (W-5500) Double Hung options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

Does Siteline Wood (W-5500) Double Hung meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 2,943 Southern-certified options inside JELD-WEN, inc. Siteline Wood (W-5500) Double Hung satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.46 SHGC on west-facing glass to avoid excess afternoon solar gain.

Are all 2,985 Siteline Wood (W-5500) Double Hung configurations ENERGY STAR Most Efficient?

All 2,985 Siteline Wood (W-5500) Double Hung listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

What federal compliance checks govern 2026 Siteline Wood (W-5500) Double Hung window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

What permanent glass etch marks verify Siteline Wood (W-5500) Double Hung after sticker removal?

Inspectors match the temporary NFRC sticker (U 0.25-0.32, SHGC 0.11-0.46) against permit drawings for line JEL-N-885. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Siteline Wood (W-5500) Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros