Andersen Corporation — E-Series Gliding Window · Double Slider
Across 111 Andersen Corporation certified families, E-Series Gliding Window supplies 2,960 Double Slider configurations starting at 0.25 U-Factor and 0.06 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.40 SHGC. Its thermal floor ranks #1,174 of 1,352 category entries—0.05 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.25
- SHGC Range
- 0.06-0.40
- Certified Options
- 2,960
- Category Standing
- #1,174 of 1,352
How does Andersen Corporation E-Series Gliding Window compare thermally against Window peers?
Andersen Corporation E-Series Gliding Window achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 111 certified Andersen Corporation series, this Double Slider offers a 0.07 U-Factor adjustment span between 0.32 entry options and 0.25 top-performing glazing. Category standing is #1,174/1,352 (tied with 81 others at 0.25, more insulating than 7.2% of Window lines).
Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 2 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Data provenance links certification 2024-08-08 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 150.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 2,960 certified glazing combinations for E-Series Gliding Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 2 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 96 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 454 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 2,924 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| JELD-WEN, inc. — Siteline Wood (W-5500) Double Hung | Wood | 0.25 | 0.11 | 2,985 |
| Marvin — Ultimate Wood Outswing French Door Transom | Wood | 0.25 | 0.10 | 1,476 |
| Marvin — Ultimate Wood Inswing French Door Transom | Wood | 0.25 | 0.10 | 1,355 |
| JELD-WEN, inc. — Custom EpicVue Clad Radius Pushout Casement | Wood | 0.25 | 0.11 | 501 |
| Windsor Windows and Doors — Revive Hybrid Pocket Double Hung | Wood | 0.25 | 0.11 | 450 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation E-Series Gliding Window appear below.
How efficient is Andersen Corporation E-Series Gliding Window compared with peer Window models?
Testing puts Andersen Corporation E-Series Gliding Window at rank #1,174 of 1,352 Window entries with U 0.25 to 0.32 across 2,960 configurations. Solar heat gain ranges between 0.06 and 0.40 across Northern, North-Central, South-Central, Southern.
Does Andersen Corporation E-Series Gliding Window qualify for the ENERGY STAR Northern Zone?
With a 0.25 minimum U-Factor, Andersen Corporation E-Series Gliding Window cannot satisfy prescriptive <= 0.22 Northern targets, yet 2 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.
How much winter heat loss does E-Series Gliding Window conduct across a 15 sq ft opening?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.25 U-Factor yields 150.0 BTU/hr conductive transfer (+13.6% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
Which situations make E-Series Gliding Window the wrong window or door choice?
Cold-climate owners needing prescriptive U <= 0.22 should pass on E-Series Gliding Window options exceeding U 0.22. Additionally, do not order Dual-Slide Horizontal (HSXX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
What Southern ENERGY STAR v7.0 options exist in E-Series Gliding Window?
Yes. 2,924 Southern-certified options inside Andersen Corporation E-Series Gliding Window satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.40 SHGC on west-facing glass to avoid excess afternoon solar gain.
Which package tier in E-Series Gliding Window holds Most Efficient recognition?
ENERGY STAR Most Efficient designation is absent across all 2,960 E-Series Gliding Window options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.
Do 2026 E-Series Gliding Window installations qualify for IRS Section 25C tax credits?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
Where are NFRC and IGCC identification marks located on E-Series Gliding Window?
Verify NFRC ID AND and series AND-N-183 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation E-Series Gliding Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)