Skip to main content
Window · Wood Frame NFRC AND · Product Line AND-N-183

Andersen Corporation — E-Series Gliding Window · Double Slider

Across 111 Andersen Corporation certified families, E-Series Gliding Window supplies 2,960 Double Slider configurations starting at 0.25 U-Factor and 0.06 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.40 SHGC. Its thermal floor ranks #1,174 of 1,352 category entries—0.05 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.25
SHGC Range
0.06-0.40
Certified Options
2,960
Category Standing
#1,174 of 1,352

How does Andersen Corporation E-Series Gliding Window compare thermally against Window peers?

Andersen Corporation E-Series Gliding Window achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. E-Series Gliding WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing E-Series Gliding Window (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

E-Series Gliding Window Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 111 certified Andersen Corporation series, this Double Slider offers a 0.07 U-Factor adjustment span between 0.32 entry options and 0.25 top-performing glazing. Category standing is #1,174/1,352 (tied with 81 others at 0.25, more insulating than 7.2% of Window lines).

Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 2 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2024-08-08 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 150.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,960 certified glazing combinations for E-Series Gliding Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 2 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 96 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 454 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 2,924 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation E-Series Gliding Window appear below.

How efficient is Andersen Corporation E-Series Gliding Window compared with peer Window models?

Testing puts Andersen Corporation E-Series Gliding Window at rank #1,174 of 1,352 Window entries with U 0.25 to 0.32 across 2,960 configurations. Solar heat gain ranges between 0.06 and 0.40 across Northern, North-Central, South-Central, Southern.

Does Andersen Corporation E-Series Gliding Window qualify for the ENERGY STAR Northern Zone?

With a 0.25 minimum U-Factor, Andersen Corporation E-Series Gliding Window cannot satisfy prescriptive <= 0.22 Northern targets, yet 2 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

How much winter heat loss does E-Series Gliding Window conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.25 U-Factor yields 150.0 BTU/hr conductive transfer (+13.6% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Which situations make E-Series Gliding Window the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on E-Series Gliding Window options exceeding U 0.22. Additionally, do not order Dual-Slide Horizontal (HSXX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

What Southern ENERGY STAR v7.0 options exist in E-Series Gliding Window?

Yes. 2,924 Southern-certified options inside Andersen Corporation E-Series Gliding Window satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.40 SHGC on west-facing glass to avoid excess afternoon solar gain.

Which package tier in E-Series Gliding Window holds Most Efficient recognition?

ENERGY STAR Most Efficient designation is absent across all 2,960 E-Series Gliding Window options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

Do 2026 E-Series Gliding Window installations qualify for IRS Section 25C tax credits?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

Where are NFRC and IGCC identification marks located on E-Series Gliding Window?

Verify NFRC ID AND and series AND-N-183 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation E-Series Gliding Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros