Skip to main content
Window · Wood Frame NFRC AND · Product Line AND-N-166

Andersen Corporation — E-Series Hinged Patio Door Sidelite - Inswing · Sidelite

With a minimum U-Factor of 0.25—+0.05 compared against the 0.20 Window median—Andersen Corporation E-Series Hinged Patio Door Sidelite - Inswing spans 1,177 tested options across Northern, North-Central, South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code AND, the Wood assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.08 and 0.32.

Min U-Factor
0.25
SHGC Range
0.08-0.32
Certified Options
1,177
Category Standing
#1,174 of 1,352

How does Andersen Corporation E-Series Hinged Patio Door Sidelite - Inswing compare thermally against Window peers?

Andersen Corporation E-Series Hinged Patio Door Sidelite - Inswing achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. E-Series Hinged Patio Door Sidelite - InswingHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing E-Series Hinged Patio Door Sidelite - Inswing (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

E-Series Hinged Patio Door Sidelite - Inswing Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 111 certified Andersen Corporation series, this Sidelite offers a 0.03 U-Factor adjustment span between 0.28 entry options and 0.25 top-performing glazing. Category standing is #1,174/1,352 (tied with 81 others at 0.25, more insulating than 7.2% of Window lines).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 294 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors AND to 2024-04-09 certification (FENSTAR issued 2019-01-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 150.0 BTU/hr conductive loss (+13.6% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,177 certified glazing combinations for E-Series Hinged Patio Door Sidelite - Inswing (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 294 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 294 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 1,123 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 1,123 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation E-Series Hinged Patio Door Sidelite - Inswing appear below.

What thermal performance numbers separate Andersen Corporation E-Series Hinged Patio Door Sidelite - Inswing from peers?

Built with Wood framing in Fixed Sidelite (FXSL) style, Andersen Corporation E-Series Hinged Patio Door Sidelite - Inswing offers 1,177 Version 7.0 configurations from U 0.25 up to 0.28, posting +0.05 against the Window median of 0.20 with 0 Most Efficient picks.

Is E-Series Hinged Patio Door Sidelite - Inswing approved for Northern Zone heating climates?

While Andersen Corporation E-Series Hinged Patio Door Sidelite - Inswing misses the <= 0.22 prescriptive mark (floor U 0.25), 294 packages still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.

How does a 3x5 ft E-Series Hinged Patio Door Sidelite - Inswing window perform under a 40 deg F temperature drop?

Using NFRC AND U-Factor 0.25, a 15 sq ft Fixed Sidelite (FXSL) assembly conducts 150.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+18.0 BTU/hr margin).

When should a buyer skip Andersen Corporation E-Series Hinged Patio Door Sidelite - Inswing and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on E-Series Hinged Patio Door Sidelite - Inswing options exceeding U 0.22. Additionally, do not order Fixed Sidelite (FXSL) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Can you install Andersen Corporation E-Series Hinged Patio Door Sidelite - Inswing in Southern or South-Central zones?

Across Northern, North-Central, South-Central, Southern, 1,123 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Andersen Corporation E-Series Hinged Patio Door Sidelite - Inswing, while total line SHGC reaches 0.32 in colder packages.

Does E-Series Hinged Patio Door Sidelite - Inswing carry EPA Most Efficient certification across its lineup?

ENERGY STAR Most Efficient designation is absent across all 1,177 E-Series Hinged Patio Door Sidelite - Inswing options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

What 2026 federal tax credit and Lead RRP rules apply to E-Series Hinged Patio Door Sidelite - Inswing?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do you cross-check NFRC AND and product line AND-N-166 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line AND-N-166 and NFRC ID AND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation E-Series Hinged Patio Door Sidelite - Inswing come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros