Andersen Corporation — E-Series Hinged Patio Door Sidelite - Inswing · Sidelite
With a minimum U-Factor of 0.25—+0.05 compared against the 0.20 Window median—Andersen Corporation E-Series Hinged Patio Door Sidelite - Inswing spans 1,177 tested options across Northern, North-Central, South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code AND, the Wood assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.08 and 0.32.
- Min U-Factor
- 0.25
- SHGC Range
- 0.08-0.32
- Certified Options
- 1,177
- Category Standing
- #1,174 of 1,352
How does Andersen Corporation E-Series Hinged Patio Door Sidelite - Inswing compare thermally against Window peers?
Andersen Corporation E-Series Hinged Patio Door Sidelite - Inswing achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 111 certified Andersen Corporation series, this Sidelite offers a 0.03 U-Factor adjustment span between 0.28 entry options and 0.25 top-performing glazing. Category standing is #1,174/1,352 (tied with 81 others at 0.25, more insulating than 7.2% of Window lines).
Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 294 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Lifecycle documentation anchors AND to 2024-04-09 certification (FENSTAR issued 2019-01-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 150.0 BTU/hr conductive loss (+13.6% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 1,177 certified glazing combinations for E-Series Hinged Patio Door Sidelite - Inswing (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 294 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 294 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 1,123 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 1,123 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Marvin — Ultimate Wood Inswing French Door Transom | Wood | 0.25 | 0.10 | 1,355 |
| Marvin — Ultimate Wood Outswing French Door Transom | Wood | 0.25 | 0.10 | 1,476 |
| JELD-WEN, inc. — Custom EpicVue Clad Radius Pushout Casement | Wood | 0.25 | 0.11 | 501 |
| Windsor Windows and Doors — Revive Hybrid Pocket Double Hung | Wood | 0.25 | 0.11 | 450 |
| Windsor Windows and Doors — Revive Primed Win-Pac | Wood | 0.25 | 0.11 | 423 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation E-Series Hinged Patio Door Sidelite - Inswing appear below.
What thermal performance numbers separate Andersen Corporation E-Series Hinged Patio Door Sidelite - Inswing from peers?
Built with Wood framing in Fixed Sidelite (FXSL) style, Andersen Corporation E-Series Hinged Patio Door Sidelite - Inswing offers 1,177 Version 7.0 configurations from U 0.25 up to 0.28, posting +0.05 against the Window median of 0.20 with 0 Most Efficient picks.
Is E-Series Hinged Patio Door Sidelite - Inswing approved for Northern Zone heating climates?
While Andersen Corporation E-Series Hinged Patio Door Sidelite - Inswing misses the <= 0.22 prescriptive mark (floor U 0.25), 294 packages still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.
How does a 3x5 ft E-Series Hinged Patio Door Sidelite - Inswing window perform under a 40 deg F temperature drop?
Using NFRC AND U-Factor 0.25, a 15 sq ft Fixed Sidelite (FXSL) assembly conducts 150.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+18.0 BTU/hr margin).
When should a buyer skip Andersen Corporation E-Series Hinged Patio Door Sidelite - Inswing and compare alternatives?
Cold-climate owners needing prescriptive U <= 0.22 should pass on E-Series Hinged Patio Door Sidelite - Inswing options exceeding U 0.22. Additionally, do not order Fixed Sidelite (FXSL) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
Can you install Andersen Corporation E-Series Hinged Patio Door Sidelite - Inswing in Southern or South-Central zones?
Across Northern, North-Central, South-Central, Southern, 1,123 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Andersen Corporation E-Series Hinged Patio Door Sidelite - Inswing, while total line SHGC reaches 0.32 in colder packages.
Does E-Series Hinged Patio Door Sidelite - Inswing carry EPA Most Efficient certification across its lineup?
ENERGY STAR Most Efficient designation is absent across all 1,177 E-Series Hinged Patio Door Sidelite - Inswing options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.
What 2026 federal tax credit and Lead RRP rules apply to E-Series Hinged Patio Door Sidelite - Inswing?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
How do you cross-check NFRC AND and product line AND-N-166 on delivery?
Confirm both the paper NFRC label and permanent corner glass etch match line AND-N-166 and NFRC ID AND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation E-Series Hinged Patio Door Sidelite - Inswing come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)