Skip to main content
Window · Fiberglass Frame NFRC MAR · Product Line MAR-N-495

Marvin — Vivid Glider · Single Slider

Marvin Vivid Glider is a Single Slider assembly with a Fiberglass frame that reaches a minimum U-Factor of 0.25 across 708 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #1,174 of 1,352 in Window, its thermal floor is 0.05 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.11 to 0.46.

Min U-Factor
0.25
SHGC Range
0.11-0.46
Certified Options
708
Category Standing
#1,174 of 1,352

How does Marvin Vivid Glider compare thermally against Window peers?

Marvin Vivid Glider achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Vivid GliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Vivid Glider (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Vivid Glider Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 105 certified Marvin series, this Single Slider offers a 0.07 U-Factor adjustment span between 0.32 entry options and 0.25 top-performing glazing. Category standing is #1,174/1,352 (tied with 81 others at 0.25, more insulating than 7.2% of Window lines).

Mapping NFRC SHGC values (0.11 to 0.46) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 26 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 150.0 BTU/hr (+13.6% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-03-05 and cert timestamp 2026-09-01.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 708 certified glazing combinations for Vivid Glider (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 26 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 66 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 296 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 658 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Vivid Glider appear below.

Where does Marvin Vivid Glider stand thermally among ENERGY STAR Window lines?

Built with Fiberglass framing in Horizontal Slider (HSOX) style, Marvin Vivid Glider offers 708 Version 7.0 configurations from U 0.25 up to 0.32, posting +0.05 against the Window median of 0.20 with 0 Most Efficient picks.

Does Marvin Vivid Glider qualify for the ENERGY STAR Northern Zone?

Because Vivid Glider starts at 0.25 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 26 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).

How much winter heat loss does Vivid Glider conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.25 U-Factor yields 150.0 BTU/hr conductive transfer (+13.6% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Who should NOT choose Marvin Vivid Glider for a residential project?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Vivid Glider options exceeding U 0.22. Verify whether your municipal code restricts Fiberglass frames in wildfire or historic zones.

Does Vivid Glider meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 658 Southern-certified options inside Marvin Vivid Glider satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.46 SHGC on west-facing glass to avoid excess afternoon solar gain.

What glazing share inside Vivid Glider qualifies as Most Efficient?

All 708 Vivid Glider listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

What 2026 federal tax credit and Lead RRP rules apply to Vivid Glider?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Vivid Glider retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do you cross-check NFRC MAR and product line MAR-N-495 on delivery?

Match the NFRC thermal sticker for code MAR and line MAR-N-495 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Vivid Glider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros