Skip to main content
Window · Other Frame NFRC WIN · Product Line WIN-N-148

Windsor Windows and Doors — Pinnacle Primed Inswing Door Transom · Transom

Windsor Windows and Doors Pinnacle Primed Inswing Door Transom is a Transom assembly with a Other frame that reaches a minimum U-Factor of 0.25 across 577 certified glazing configurations covering North-Central, South-Central, Southern. Ranked #1,174 of 1,352 in Window, its thermal floor is 0.05 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.12 to 0.23.

Min U-Factor
0.25
SHGC Range
0.12-0.23
Certified Options
577
Category Standing
#1,174 of 1,352

How does Windsor Windows and Doors Pinnacle Primed Inswing Door Transom compare thermally against Window peers?

Windsor Windows and Doors Pinnacle Primed Inswing Door Transom achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Pinnacle Primed Inswing Door TransomHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Pinnacle Primed Inswing Door Transom (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Pinnacle Primed Inswing Door Transom Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 82 certified Windsor Windows and Doors series, this Transom offers a 0.07 U-Factor adjustment span between 0.32 entry options and 0.25 top-performing glazing. Category standing is #1,174/1,352 (tied with 81 others at 0.25, more insulating than 7.2% of Window lines).

Mapping NFRC SHGC values (0.12 to 0.23) against ENERGY STAR Version 7.0 targets approves North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.12 lowers cooling load.

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2026-03-12. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.25 conducts 150.0 BTU/hr (+18.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 577 certified glazing combinations for Pinnacle Primed Inswing Door Transom (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 6 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 149 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 577 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
ABI Windows LLC — 500 Horizontal Slider Window Vinyl 0.25 0.10 516
JELD-WEN, inc. — Custom EpicVue Clad Radius Pushout Casement Wood 0.25 0.11 501
Anlin Industries — Coronado/Monte Verde/Bayview/Extreme Awning Vinyl 0.25 0.11 495
Marvin — Vivid Glider Fiberglass 0.25 0.11 708
JELD-WEN, inc. — Premium Atlantic Vinyl Single Hung Vinyl 0.25 0.13 408

What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Pinnacle Primed Inswing Door Transom appear below.

How efficient is Windsor Windows and Doors Pinnacle Primed Inswing Door Transom compared with peer Window models?

EPA ENERGY STAR v7.0 records 577 configurations for Windsor Windows and Doors Pinnacle Primed Inswing Door Transom covering North-Central, South-Central, Southern, dropping down to U 0.25 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Which glazing options in Windsor Windows and Doors Pinnacle Primed Inswing Door Transom meet Northern climate limits?

This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.25). Focus on North-Central, South-Central, Southern glazing applications where SHGC 0.12-0.23 manages cooling loads.

How does a 3x5 ft Pinnacle Primed Inswing Door Transom window perform under a 40 deg F temperature drop?

At U 0.25, a standard 3x5 ft (15 sq ft) Pinnacle Primed Inswing Door Transom opening transfers 150.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +18.0 BTU/hr difference.

When should a buyer skip Windsor Windows and Doors Pinnacle Primed Inswing Door Transom and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Pinnacle Primed Inswing Door Transom options exceeding U 0.22. Verify whether your municipal code restricts Other frames in wildfire or historic zones.

What Southern ENERGY STAR v7.0 options exist in Pinnacle Primed Inswing Door Transom?

Across North-Central, South-Central, Southern, 577 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Windsor Windows and Doors Pinnacle Primed Inswing Door Transom, while total line SHGC reaches 0.23 in colder packages.

Which package tier in Pinnacle Primed Inswing Door Transom holds Most Efficient recognition?

Pinnacle Primed Inswing Door Transom holds zero Most Efficient entries across its 577 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

How do the 25C sunset and pre-1978 Lead RRP rules affect Pinnacle Primed Inswing Door Transom?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How can homeowners confirm delivered Windsor Windows and Doors Pinnacle Primed Inswing Door Transom units match permits?

Inspectors match the temporary NFRC sticker (U 0.25-0.32, SHGC 0.12-0.23) against permit drawings for line WIN-N-148. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Pinnacle Primed Inswing Door Transom come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros