Andersen Corporation — 100 Series/Series 2 Single Hung Window · Single Hung
Andersen Corporation 100 Series/Series 2 Single Hung Window is a Single Hung assembly with a Composite frame that reaches a minimum U-Factor of 0.25 across 866 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #1,174 of 1,352 in Window, its thermal floor is 0.05 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.15 to 0.47.
- Min U-Factor
- 0.25
- SHGC Range
- 0.15-0.47
- Certified Options
- 866
- Category Standing
- #1,174 of 1,352
How does Andersen Corporation 100 Series/Series 2 Single Hung Window compare thermally against Window peers?
Andersen Corporation 100 Series/Series 2 Single Hung Window achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Composite cohort (0.22 median U-Factor), 100 Series/Series 2 Single Hung Window reaches 0.25 on its lowest-conductivity package — #13 of 21 in Composite, tied with 3 others at 0.25, more insulating than 23.8% of Composite lines (+0.03 vs Composite peers). Pairing NFRC ID AND across multi-pane fills shifts U-Factor from 0.32 down toward 0.25.
Mapping NFRC SHGC values (0.15 to 0.47) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 12 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Registry history records EPA FENSTAR licensing on 2019-01-08 and v7.0 data certification on 2025-06-09. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.25 conducts 150.0 BTU/hr (+18.0 BTU/hr vs the 0.22 ceiling).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 866 certified glazing combinations for 100 Series/Series 2 Single Hung Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 12 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 12 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 174 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 854 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| YKK AP America, Inc. — Style View/Precedence/Style View Classic Double Hung | Vinyl | 0.25 | 0.18 | 885 |
| YKK AP America, Inc. — Style View/Style View NT/Precedence/Style View Classic Single Hung | Vinyl | 0.25 | 0.18 | 947 |
| JELD-WEN, inc. — Brickmould Vinyl (V-3700) Horizontal Slider | Vinyl | 0.25 | 0.13 | 782 |
| YKK AP America, Inc. — Style View/Style View Classic Single Hung Archtop | Vinyl | 0.25 | 0.18 | 1,016 |
| Marvin — Vivid Glider | Fiberglass | 0.25 | 0.11 | 708 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 100 Series/Series 2 Single Hung Window appear below.
What U-Factor and SHGC range does Andersen Corporation 100 Series/Series 2 Single Hung Window achieve?
Across 866 tested NFRC glazing configurations, Andersen Corporation 100 Series/Series 2 Single Hung Window with Composite framing and Single-Hung (VSSH) style reaches a 0.25 minimum U-Factor and 0.15-0.47 SHGC band. It places #1,174 among 1,352 Window series—more insulating than 7.2%.
How does Andersen Corporation 100 Series/Series 2 Single Hung Window satisfy Version 7.0 Northern criteria?
While Andersen Corporation 100 Series/Series 2 Single Hung Window misses the <= 0.22 prescriptive mark (floor U 0.25), 12 packages still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.
How does a 3x5 ft 100 Series/Series 2 Single Hung Window window perform under a 40 deg F temperature drop?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 150.0 BTU/hr on 100 Series/Series 2 Single Hung Window's lowest-U package (0.25), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.
Who should NOT choose Andersen Corporation 100 Series/Series 2 Single Hung Window for a residential project?
Do not specify 100 Series/Series 2 Single Hung Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 100 Series/Series 2 Single Hung Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
Can you install Andersen Corporation 100 Series/Series 2 Single Hung Window in Southern or South-Central zones?
Yes. 854 Southern-certified options inside Andersen Corporation 100 Series/Series 2 Single Hung Window satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.47 SHGC on west-facing glass to avoid excess afternoon solar gain.
Does 100 Series/Series 2 Single Hung Window carry EPA Most Efficient certification across its lineup?
100 Series/Series 2 Single Hung Window holds zero Most Efficient entries across its 866 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.
What federal compliance checks govern 2026 100 Series/Series 2 Single Hung Window window swaps?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 Andersen Corporation upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
What permanent glass etch marks verify 100 Series/Series 2 Single Hung Window after sticker removal?
Confirm both the paper NFRC label and permanent corner glass etch match line AND-N-80 and NFRC ID AND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 100 Series/Series 2 Single Hung Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)