With a minimum U-Factor of 0.15—-0.05 compared against the 0.20 Window median—Masonite International Corporation Masonite Steel Wood Edge Steel Sidelite spans 84,195 tested options across Northern, North-Central, South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code STN, the Wood assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.01 and 0.19.

Min U-Factor
0.15
SHGC Range
0.01-0.19
Certified Options
84,195
Category Standing
#136 of 1,352

How does Masonite International Corporation Masonite Steel Wood Edge Steel Sidelite compare thermally against Window peers?

Masonite International Corporation Masonite Steel Wood Edge Steel Sidelite achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Masonite Steel Wood Edge Steel SideliteHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing Masonite Steel Wood Edge Steel Sidelite (U 0.15).249<=0.15This model: U 0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Masonite Steel Wood Edge Steel Sidelite Cohort StandingMin U-Factor 0.15 stands at rank #136 of 1,352, outperforming 81.6% of peers.Min U-Factor 0.15Rank #136 of 1,352 (81.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Masonite Steel Wood Edge Steel Sidelite spans 84,195 NFRC test records (STN), ranking #136 of 1,352 Window families (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%). Its 0.15 thermal floor compares at -0.06 against the Wood median (0.21).

Mapping NFRC SHGC values (0.01 to 0.19) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 78,064 combinations qualify in the Northern Zone alongside 84,195 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 90.0 BTU/hr (-31.8% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-02-29.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 84,195 certified glazing combinations for Masonite Steel Wood Edge Steel Sidelite (NFRC STN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 78,064 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 78,064 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 84,195 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 84,195 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Masonite International Corporation produce?

Compare other active Masonite International Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Masonite International Corporation Masonite Steel Wood Edge Steel Sidelite appear below.

What thermal performance numbers separate Masonite International Corporation Masonite Steel Wood Edge Steel Sidelite from peers?

Built with Wood framing in Fixed Sidelite (FXSL) style, Masonite International Corporation Masonite Steel Wood Edge Steel Sidelite offers 84,195 Version 7.0 configurations from U 0.15 up to 0.28, posting -0.05 against the Window median of 0.20 with 0 Most Efficient picks.

Can homeowners install Masonite Steel Wood Edge Steel Sidelite in cold Northern ENERGY STAR counties?

Prescriptive Northern compliance covers 78,064 Masonite Steel Wood Edge Steel Sidelite packages (U floor 0.15, SHGC >= 0.17). Because the complete series stretches up to U 0.28, specify the cold-climate glass code explicitly.

What conductive BTU/hr difference separates Masonite Steel Wood Edge Steel Sidelite from the 0.22 Northern rule?

At U 0.15, a standard 3x5 ft (15 sq ft) Masonite Steel Wood Edge Steel Sidelite opening transfers 90.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -42.0 BTU/hr difference.

When should a buyer skip Masonite International Corporation Masonite Steel Wood Edge Steel Sidelite and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Masonite Steel Wood Edge Steel Sidelite options exceeding U 0.22. Additionally, do not order Fixed Sidelite (FXSL) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

What Southern ENERGY STAR v7.0 options exist in Masonite Steel Wood Edge Steel Sidelite?

Yes. 84,195 Southern-certified options inside Masonite International Corporation Masonite Steel Wood Edge Steel Sidelite satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.19 SHGC on west-facing glass to avoid excess afternoon solar gain.

Are all 84,195 Masonite Steel Wood Edge Steel Sidelite configurations ENERGY STAR Most Efficient?

All 84,195 Masonite Steel Wood Edge Steel Sidelite listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

Do 2026 Masonite Steel Wood Edge Steel Sidelite installations qualify for IRS Section 25C tax credits?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

What permanent glass etch marks verify Masonite Steel Wood Edge Steel Sidelite after sticker removal?

Confirm both the paper NFRC label and permanent corner glass etch match line STN-M-26 and NFRC ID STN before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Masonite International Corporation Masonite Steel Wood Edge Steel Sidelite come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros