Skip to main content
Window · Wood Frame NFRC STN · Product Line STN-K-28

Masonite International Corporation — Masonite Steel Wood Edge Steel Sidelite · Sidelite

Masonite International Corporation Masonite Steel Wood Edge Steel Sidelite is a Sidelite assembly with a Wood frame that reaches a minimum U-Factor of 0.15 across 84,318 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #136 of 1,352 in Window, its thermal floor is 0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.01 to 0.19.

Min U-Factor
0.15
SHGC Range
0.01-0.19
Certified Options
84,318
Category Standing
#136 of 1,352

How does Masonite International Corporation Masonite Steel Wood Edge Steel Sidelite compare thermally against Window peers?

Masonite International Corporation Masonite Steel Wood Edge Steel Sidelite achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Masonite Steel Wood Edge Steel SideliteHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing Masonite Steel Wood Edge Steel Sidelite (U 0.15).249<=0.15This model: U 0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Masonite Steel Wood Edge Steel Sidelite Cohort StandingMin U-Factor 0.15 stands at rank #136 of 1,352, outperforming 81.6% of peers.Min U-Factor 0.15Rank #136 of 1,352 (81.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Masonite Steel Wood Edge Steel Sidelite is 0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.15-0.28.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 78,174 combinations qualify in the Northern Zone alongside 84,318 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Data provenance links certification 2025-12-05 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 90.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 84,318 certified glazing combinations for Masonite Steel Wood Edge Steel Sidelite (NFRC STN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 78,174 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 78,174 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 84,318 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 84,318 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Masonite International Corporation produce?

Compare other active Masonite International Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Masonite International Corporation Masonite Steel Wood Edge Steel Sidelite appear below.

What thermal performance numbers separate Masonite International Corporation Masonite Steel Wood Edge Steel Sidelite from peers?

EPA ENERGY STAR v7.0 records 84,318 configurations for Masonite International Corporation Masonite Steel Wood Edge Steel Sidelite covering Northern, North-Central, South-Central, Southern, dropping down to U 0.15 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Does Masonite International Corporation Masonite Steel Wood Edge Steel Sidelite qualify for the ENERGY STAR Northern Zone?

Masonite International Corporation Masonite Steel Wood Edge Steel Sidelite supplies 78,174 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.28, so inspect the NFRC order sheet before purchase.

What BTU/hr heat transfer results from Masonite Steel Wood Edge Steel Sidelite's 0.15 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.15 U-Factor yields 90.0 BTU/hr conductive transfer (-31.8% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What homeowner profiles are a poor match for Masonite International Corporation Masonite Steel Wood Edge Steel Sidelite?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Masonite Steel Wood Edge Steel Sidelite options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Can you install Masonite International Corporation Masonite Steel Wood Edge Steel Sidelite in Southern or South-Central zones?

Yes. 84,318 Southern-certified options inside Masonite International Corporation Masonite Steel Wood Edge Steel Sidelite satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.19 SHGC on west-facing glass to avoid excess afternoon solar gain.

How many Masonite International Corporation Masonite Steel Wood Edge Steel Sidelite variants earn ENERGY STAR Most Efficient?

All 84,318 Masonite Steel Wood Edge Steel Sidelite listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

What 2026 federal tax credit and Lead RRP rules apply to Masonite Steel Wood Edge Steel Sidelite?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Masonite Steel Wood Edge Steel Sidelite installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

What permanent glass etch marks verify Masonite Steel Wood Edge Steel Sidelite after sticker removal?

Inspectors match the temporary NFRC sticker (U 0.15-0.28, SHGC 0.01-0.19) against permit drawings for line STN-K-28. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Masonite International Corporation Masonite Steel Wood Edge Steel Sidelite come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)