Pella Corporation — Pella Architect Reserve Double Hung, Clad, Model 5 · Double Hung

With a minimum U-Factor of 0.24—+0.04 compared against the 0.20 Window median—Pella Corporation Pella Architect Reserve Double Hung, Clad, Model 5 spans 402 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code PEL, the Other / Wood assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.11 and 0.48.

Min U-Factor
0.24
SHGC Range
0.11-0.48
Certified Options
402
Category Standing
#1,034 of 1,352

How does Pella Corporation Pella Architect Reserve Double Hung, Clad, Model 5 compare thermally against Window peers?

Pella Corporation Pella Architect Reserve Double Hung, Clad, Model 5 achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Pella Architect Reserve Double Hung, Clad, Model 5Histogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Pella Architect Reserve Double Hung, Clad, Model 5 (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Pella Architect Reserve Double Hung, Clad, Model 5 Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Pella Corporation Pella Architect Reserve Double Hung, Clad, Model 5 standing at #1,034 of 1,352 certified Window product series, tied with 139 others at 0.24, more insulating than 13.2% of Window lines. Comparing Other / Wood profiles alone (median 0.18) shows +0.06 before selecting Low-E tiers.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 22 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Registry history records EPA FENSTAR licensing on 2018-02-20 and v7.0 data certification on 2024-12-19. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.24 conducts 144.0 BTU/hr (+12.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 402 certified glazing combinations for Pella Architect Reserve Double Hung, Clad, Model 5 (NFRC PEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 22 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 36 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 125 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 366 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Marvin — Elevate Glider Wood 0.24 0.17 402
Thermo-Tech Windows — 7600 Double Hung Vinyl 0.24 0.15 404
Westlake Royal Windows LLC — 700 Single Hung Vinyl 0.24 0.16 405
Quaker Window Products — V100 Single Hung Vinyl 0.24 0.14 398
Andersen Corporation — 400 Series Frenchwood® Patio Door Sidelight Wood 0.24 0.10 396

What other certified series does Pella Corporation produce?

Compare other active Pella Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Pella Corporation Pella Architect Reserve Double Hung, Clad, Model 5 appear below.

Where does Pella Corporation Pella Architect Reserve Double Hung, Clad, Model 5 stand thermally among ENERGY STAR Window lines?

Testing puts Pella Corporation Pella Architect Reserve Double Hung, Clad, Model 5 at rank #1,034 of 1,352 Window entries with U 0.24 to 0.32 across 402 configurations. Solar heat gain ranges between 0.11 and 0.48 across Northern, North-Central, South-Central, Southern.

Does Pella Corporation Pella Architect Reserve Double Hung, Clad, Model 5 qualify for the ENERGY STAR Northern Zone?

While Pella Corporation Pella Architect Reserve Double Hung, Clad, Model 5 misses the <= 0.22 prescriptive mark (floor U 0.24), 22 packages still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.

What BTU/hr heat transfer results from Pella Architect Reserve Double Hung, Clad, Model 5's 0.24 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Pella Architect Reserve Double Hung, Clad, Model 5 at U 0.24 conducts 144.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

When should a buyer skip Pella Corporation Pella Architect Reserve Double Hung, Clad, Model 5 and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Pella Architect Reserve Double Hung, Clad, Model 5 options exceeding U 0.22. Verify whether your municipal code restricts Other / Wood frames in wildfire or historic zones.

Can you install Pella Corporation Pella Architect Reserve Double Hung, Clad, Model 5 in Southern or South-Central zones?

Exactly 366 Pella Architect Reserve Double Hung, Clad, Model 5 options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.11 rather than higher 0.48 glass.

What glazing share inside Pella Architect Reserve Double Hung, Clad, Model 5 qualifies as Most Efficient?

Pella Architect Reserve Double Hung, Clad, Model 5 holds zero Most Efficient entries across its 402 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

What 2026 federal tax credit and Lead RRP rules apply to Pella Architect Reserve Double Hung, Clad, Model 5?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Pella Architect Reserve Double Hung, Clad, Model 5 retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How can homeowners confirm delivered Pella Corporation Pella Architect Reserve Double Hung, Clad, Model 5 units match permits?

Verify NFRC ID PEL and series PEL-N-232 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Pella Corporation Pella Architect Reserve Double Hung, Clad, Model 5 come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros