Quaker Window Products engineered the W200 Inswing & Outswing Door Swinging Entry Door, Single line for Northern, North-Central, South-Central, Southern, certifying 5,680 glass-spacer combinations from 0.24 to 0.28 U-Factor and 0.10 to 0.28 SHGC. Relative to other Aluminum models tracked under NFRC QWP, its minimum U-Factor is 0.01 Btu/hr·ft²·°F less insulating than the 0.23 Btu/hr·ft²·°F median.

Min U-Factor
0.24
SHGC Range
0.10-0.28
Certified Options
5,680
Category Standing
#199 of 268

How does Quaker Window Products W200 Inswing & Outswing Door compare thermally against Door peers?

Quaker Window Products W200 Inswing & Outswing Door achieves a 0.24 thermal floor across Door lines, placing #199 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. W200 Inswing & Outswing DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing W200 Inswing & Outswing Door (U 0.24).28<=0.15650.16-0.18510.19-0.21710.22-0.24This model: U 0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

W200 Inswing & Outswing Door Cohort StandingMin U-Factor 0.24 stands at rank #199 of 268, outperforming 19.8% of peers.Min U-Factor 0.24Rank #199 of 268 (19.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 25 certified Quaker Window Products series, this Swinging Entry Door, Single offers a 0.04 U-Factor adjustment span between 0.28 entry options and 0.24 top-performing glazing. Category standing is #199/268 (tied with 16 others at 0.24, more insulating than 19.8% of Door lines).

Climate coverage for Quaker Window Products W200 Inswing & Outswing Door spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 2,170 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2024-08-08 and FENSTAR license 2018-02-20 inside EPA Version 7.0 tables. Heat transfer computes to 144.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 5,680 certified glazing combinations for W200 Inswing & Outswing Door (NFRC QWP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 2,170 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 2,170 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 5,477 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 5,477 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Quaker Window Products produce?

Compare other active Quaker Window Products certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Quaker Window Products W200 Inswing & Outswing Door appear below.

What U-Factor and SHGC range does Quaker Window Products W200 Inswing & Outswing Door achieve?

EPA ENERGY STAR v7.0 records 5,680 configurations for Quaker Window Products W200 Inswing & Outswing Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.24 versus a 0.21 Door median. Only 0 options earn Most Efficient status.

Can homeowners install W200 Inswing & Outswing Door in cold Northern ENERGY STAR counties?

Northern qualification on W200 Inswing & Outswing Door relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.24. Exactly 2,170 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.

What BTU/hr heat transfer results from W200 Inswing & Outswing Door's 0.24 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), W200 Inswing & Outswing Door at U 0.24 conducts 144.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What homeowner profiles are a poor match for Quaker Window Products W200 Inswing & Outswing Door?

Do not specify W200 Inswing & Outswing Door without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on W200 Inswing & Outswing Door options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

How many W200 Inswing & Outswing Door glazing packages pass Southern solar-heat rules?

Yes. 5,477 Southern-certified options inside Quaker Window Products W200 Inswing & Outswing Door satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.28 SHGC on west-facing glass to avoid excess afternoon solar gain.

Does W200 Inswing & Outswing Door carry EPA Most Efficient certification across its lineup?

Zero glazing builds inside W200 Inswing & Outswing Door's 5,680 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

What federal compliance checks govern 2026 W200 Inswing & Outswing Door window swaps?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 W200 Inswing & Outswing Door installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

Where are NFRC and IGCC identification marks located on W200 Inswing & Outswing Door?

Confirm both the paper NFRC label and permanent corner glass etch match line QWP-M-131 and NFRC ID QWP before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Quaker Window Products W200 Inswing & Outswing Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)