Door · Wood Frame NFRC AND · Product Line AND-N-193

Andersen Corporation — Outswing Folding Door Traditional Cladding · Swinging Entry Door (Single)

Positioning #199/268 in certified Door, Andersen Corporation Outswing Folding Door Traditional Cladding pairs Wood frame construction with 5,520 glazing options rated between 0.08 and 0.35 SHGC across Northern, North-Central, South-Central, Southern. Across 111 certified Andersen Corporation product families, its thermal resistance spans 0.24 to 0.28 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.24
SHGC Range
0.08-0.35
Certified Options
5,520
Category Standing
#199 of 268

How does Andersen Corporation Outswing Folding Door Traditional Cladding compare thermally against Door peers?

Andersen Corporation Outswing Folding Door Traditional Cladding achieves a 0.24 thermal floor across Door lines, placing #199 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Outswing Folding Door Traditional CladdingHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Outswing Folding Door Traditional Cladding (U 0.24).28<=0.15650.16-0.18510.19-0.21710.22-0.24This model: U 0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Outswing Folding Door Traditional Cladding Cohort StandingMin U-Factor 0.24 stands at rank #199 of 268, outperforming 19.8% of peers.Min U-Factor 0.24Rank #199 of 268 (19.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Door assemblies nationwide (median U 0.21), Outswing Folding Door Traditional Cladding is 0.03 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.24-0.28.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 1,601 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2026-09-25 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 144.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 5,520 certified glazing combinations for Outswing Folding Door Traditional Cladding (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 1,601 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 1,601 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 5,125 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 5,125 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation Outswing Folding Door Traditional Cladding appear below.

How well does Outswing Folding Door Traditional Cladding by Andersen Corporation insulate relative to Door benchmarks?

EPA ENERGY STAR v7.0 records 5,520 configurations for Andersen Corporation Outswing Folding Door Traditional Cladding covering Northern, North-Central, South-Central, Southern, dropping down to U 0.24 versus a 0.21 Door median. Only 0 options earn Most Efficient status.

Does Andersen Corporation Outswing Folding Door Traditional Cladding qualify for the ENERGY STAR Northern Zone?

With a 0.24 minimum U-Factor, Andersen Corporation Outswing Folding Door Traditional Cladding cannot satisfy prescriptive <= 0.22 Northern targets, yet 1,601 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

What conductive BTU/hr difference separates Outswing Folding Door Traditional Cladding from the 0.22 Northern rule?

At U 0.24, a standard 3x5 ft (15 sq ft) Outswing Folding Door Traditional Cladding opening transfers 144.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +12.0 BTU/hr difference.

Who should NOT choose Andersen Corporation Outswing Folding Door Traditional Cladding for a residential project?

Skip Outswing Folding Door Traditional Cladding if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Outswing Folding Door Traditional Cladding options exceeding U 0.22.

Is Outswing Folding Door Traditional Cladding suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 5,125 Southern-approved options within Outswing Folding Door Traditional Cladding spanning SHGC down to 0.08. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Does Outswing Folding Door Traditional Cladding carry EPA Most Efficient certification across its lineup?

All 5,520 Outswing Folding Door Traditional Cladding listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

What 2026 federal tax credit and Lead RRP rules apply to Outswing Folding Door Traditional Cladding?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Outswing Folding Door Traditional Cladding retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do building inspectors verify Outswing Folding Door Traditional Cladding glass specs on job sites?

Verify NFRC ID AND and series AND-N-193 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation Outswing Folding Door Traditional Cladding come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)