Skip to main content
Window · Vinyl Frame NFRC WIN · Product Line WIN-N-190 ENERGY STAR Most Efficient Eligible

Windsor Windows and Doors — Next Dimension Double Hung · Double Hung

Positioning #564/1,352 in certified Window, Windsor Windows and Doors Next Dimension Double Hung pairs Vinyl frame construction with 3,363 glazing options rated between 0.11 and 0.47 SHGC across Northern, North-Central, South-Central, Southern. Across 82 certified Windsor Windows and Doors product families, its thermal resistance spans 0.19 to 0.32 U-Factor and the line includes 201 ENERGY STAR Most Efficient packages (6.0% of line).

Min U-Factor
0.19
SHGC Range
0.11-0.47
Certified Options
3,363
Category Standing
#564 of 1,352

How does Windsor Windows and Doors Next Dimension Double Hung compare thermally against Window peers?

Windsor Windows and Doors Next Dimension Double Hung achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Next Dimension Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Next Dimension Double Hung (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Next Dimension Double Hung Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Next Dimension Double Hung spans 3,363 NFRC test records (WIN), ranking #564 of 1,352 Window families (tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%). Its 0.19 thermal floor compares at At median against the Vinyl median (0.19).

Regional qualification covers Northern, North-Central, South-Central, Southern. 201 configurations meet ENERGY STAR Most Efficient criteria while 341 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2025-08-21 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 114.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,363 certified glazing combinations for Next Dimension Double Hung (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 341 packages (57 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 568 packages (110 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 1,616 packages (64 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 3,025 packages (144 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Next Dimension Double Hung appear below.

What thermal performance numbers separate Windsor Windows and Doors Next Dimension Double Hung from peers?

EPA ENERGY STAR v7.0 records 3,363 configurations for Windsor Windows and Doors Next Dimension Double Hung covering Northern, North-Central, South-Central, Southern, dropping down to U 0.19 versus a 0.20 Window median. Only 201 options earn Most Efficient status.

Which glazing options in Windsor Windows and Doors Next Dimension Double Hung meet Northern climate limits?

Yes. 341 packages in Windsor Windows and Doors Next Dimension Double Hung clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

What conductive BTU/hr difference separates Next Dimension Double Hung from the 0.22 Northern rule?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 114.0 BTU/hr on Next Dimension Double Hung's lowest-U package (0.19), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

Which situations make Next Dimension Double Hung the wrong window or door choice?

Skip Next Dimension Double Hung if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Next Dimension Double Hung options exceeding U 0.22.

Is Next Dimension Double Hung suitable for sunbelt cooling-dominated homes?

Yes, Next Dimension Double Hung holds 3,025 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.11 SHGC in cooling climates.

Are all 3,363 Next Dimension Double Hung configurations ENERGY STAR Most Efficient?

EPA lists 201 Most Efficient options (6.0% share) inside Windsor Windows and Doors Next Dimension Double Hung, out of 3,363 total Version 7.0 entries.

Do 2026 Next Dimension Double Hung installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Next Dimension Double Hung installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do building inspectors verify Next Dimension Double Hung glass specs on job sites?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code WIN and product line WIN-N-190, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Next Dimension Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros