Skip to main content
Window · Vinyl Frame NFRC WIN · Product Line WIN-N-144

Windsor Windows and Doors — Next Dimension Pro Brickmould Single Hung · Single Hung

Windsor Windows and Doors Next Dimension Pro Brickmould Single Hung is a Single Hung assembly with a Vinyl frame that reaches a minimum U-Factor of 0.24 across 234 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #1,034 of 1,352 in Window, its thermal floor is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.16 to 0.49.

Min U-Factor
0.24
SHGC Range
0.16-0.49
Certified Options
234
Category Standing
#1,034 of 1,352

How does Windsor Windows and Doors Next Dimension Pro Brickmould Single Hung compare thermally against Window peers?

Windsor Windows and Doors Next Dimension Pro Brickmould Single Hung achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Next Dimension Pro Brickmould Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Next Dimension Pro Brickmould Single Hung (U 0.24).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Next Dimension Pro Brickmould Single Hung Cohort StandingMin U-Factor 0.24 stands at rank #1,034 of 1,352, outperforming 13.2% of peers.Min U-Factor 0.24Rank #1,034 of 1,352 (13.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Next Dimension Pro Brickmould Single Hung is 0.04 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.24-0.32.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 10 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.24 U-Factor yields 144.0 BTU/hr transfer (+12.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-02-17 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 234 certified glazing combinations for Next Dimension Pro Brickmould Single Hung (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 10 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 13 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 56 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 224 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Next Dimension Pro Brickmould Single Hung appear below.

What thermal performance numbers separate Windsor Windows and Doors Next Dimension Pro Brickmould Single Hung from peers?

Across 234 tested NFRC glazing configurations, Windsor Windows and Doors Next Dimension Pro Brickmould Single Hung with Vinyl framing and Single-Hung (VSSH) style reaches a 0.24 minimum U-Factor and 0.16-0.49 SHGC band. It places #1,034 among 1,352 Window series—more insulating than 13.2%.

Is Next Dimension Pro Brickmould Single Hung approved for Northern Zone heating climates?

Northern qualification on Next Dimension Pro Brickmould Single Hung relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.24. Exactly 10 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.

What conductive BTU/hr difference separates Next Dimension Pro Brickmould Single Hung from the 0.22 Northern rule?

Using NFRC WIN U-Factor 0.24, a 15 sq ft Single-Hung (VSSH) assembly conducts 144.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+12.0 BTU/hr margin).

What are the practical limitations of specifying Next Dimension Pro Brickmould Single Hung?

Do not specify Next Dimension Pro Brickmould Single Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Next Dimension Pro Brickmould Single Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Does Next Dimension Pro Brickmould Single Hung meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 224 Southern-certified options inside Windsor Windows and Doors Next Dimension Pro Brickmould Single Hung satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.49 SHGC on west-facing glass to avoid excess afternoon solar gain.

What glazing share inside Next Dimension Pro Brickmould Single Hung qualifies as Most Efficient?

All 234 Next Dimension Pro Brickmould Single Hung listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

Do 2026 Next Dimension Pro Brickmould Single Hung installations qualify for IRS Section 25C tax credits?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Next Dimension Pro Brickmould Single Hung retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

What permanent glass etch marks verify Next Dimension Pro Brickmould Single Hung after sticker removal?

Confirm both the paper NFRC label and permanent corner glass etch match line WIN-N-144 and NFRC ID WIN before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Next Dimension Pro Brickmould Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)