Skip to main content
Window · Vinyl Frame NFRC WIN · Product Line WIN-N-194 ENERGY STAR Most Efficient Eligible

Windsor Windows and Doors — Next Dimension Single Hung · Single Hung

With a minimum U-Factor of 0.19—-0.01 compared against the 0.20 Window median—Windsor Windows and Doors Next Dimension Single Hung spans 3,167 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code WIN, the Vinyl assembly includes 188 ENERGY STAR Most Efficient packages (5.9% of line) and offers SHGC packages between 0.12 and 0.49.

Min U-Factor
0.19
SHGC Range
0.12-0.49
Certified Options
3,167
Category Standing
#564 of 1,352

How does Windsor Windows and Doors Next Dimension Single Hung compare thermally against Window peers?

Windsor Windows and Doors Next Dimension Single Hung achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Next Dimension Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Next Dimension Single Hung (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Next Dimension Single Hung Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Next Dimension Single Hung is 0.01 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.19-0.32.

Regional qualification covers Northern, North-Central, South-Central, Southern. 188 configurations meet ENERGY STAR Most Efficient criteria while 335 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors WIN to 2025-08-21 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 114.0 BTU/hr conductive loss (-13.6% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,167 certified glazing combinations for Next Dimension Single Hung (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 335 packages (66 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 546 packages (104 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 1,390 packages (60 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 2,837 packages (134 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Next Dimension Single Hung appear below.

What thermal performance numbers separate Windsor Windows and Doors Next Dimension Single Hung from peers?

Testing puts Windsor Windows and Doors Next Dimension Single Hung at rank #564 of 1,352 Window entries with U 0.19 to 0.32 across 3,167 configurations. Solar heat gain ranges between 0.12 and 0.49 across Northern, North-Central, South-Central, Southern.

Which glazing options in Windsor Windows and Doors Next Dimension Single Hung meet Northern climate limits?

Cold-climate buyers get 335 compliant Northern packages inside Next Dimension Single Hung, reaching down to U 0.19. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

How do you calculate winter heat conduction for Windsor Windows and Doors Next Dimension Single Hung?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.19 U-Factor yields 114.0 BTU/hr conductive transfer (-13.6% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

When should a buyer skip Windsor Windows and Doors Next Dimension Single Hung and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Next Dimension Single Hung options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

What Southern ENERGY STAR v7.0 options exist in Next Dimension Single Hung?

Exactly 2,837 Next Dimension Single Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.12 rather than higher 0.49 glass.

How many Windsor Windows and Doors Next Dimension Single Hung variants earn ENERGY STAR Most Efficient?

Within Next Dimension Single Hung, 5.9% (188 of 3,167) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

How do the 25C sunset and pre-1978 Lead RRP rules affect Next Dimension Single Hung?

Any Next Dimension Single Hung purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do you cross-check NFRC WIN and product line WIN-N-194 on delivery?

Match the NFRC thermal sticker for code WIN and line WIN-N-194 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Next Dimension Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros