Skip to main content
Window · Other Frame NFRC WIN · Product Line WIN-N-116

Windsor Windows and Doors — Pinnacle Clad Double Hung · Double Hung

Windsor Windows and Doors Pinnacle Clad Double Hung is a Double Hung assembly with a Other frame that reaches a minimum U-Factor of 0.27 across 463 certified glazing configurations covering South-Central, Southern. Ranked #1,292 of 1,352 in Window, its thermal floor is 0.07 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.14 to 0.23.

Min U-Factor
0.27
SHGC Range
0.14-0.23
Certified Options
463
Category Standing
#1,292 of 1,352

How does Windsor Windows and Doors Pinnacle Clad Double Hung compare thermally against Window peers?

Windsor Windows and Doors Pinnacle Clad Double Hung achieves a 0.27 thermal floor across Window lines, placing #1,292 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Pinnacle Clad Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Pinnacle Clad Double Hung (U 0.27).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Pinnacle Clad Double Hung Cohort StandingMin U-Factor 0.27 stands at rank #1,292 of 1,352, outperforming 2.4% of peers.Min U-Factor 0.27Rank #1,292 of 1,352 (2.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 82 certified Windsor Windows and Doors series, this Double Hung offers a 0.05 U-Factor adjustment span between 0.32 entry options and 0.27 top-performing glazing. Category standing is #1,292/1,352 (tied with 27 others at 0.27, more insulating than 2.4% of Window lines).

Mapping NFRC SHGC values (0.14 to 0.23) against ENERGY STAR Version 7.0 targets approves South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.14 lowers cooling load.

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2024-02-20. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.27 conducts 162.0 BTU/hr (+30.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 463 certified glazing combinations for Pinnacle Clad Double Hung (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 60 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 463 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.27 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Pinnacle Clad Double Hung appear below.

What U-Factor and SHGC range does Windsor Windows and Doors Pinnacle Clad Double Hung achieve?

Across 463 tested NFRC glazing configurations, Windsor Windows and Doors Pinnacle Clad Double Hung with Other framing and Double-Hung (VSDH) style reaches a 0.27 minimum U-Factor and 0.14-0.23 SHGC band. It places #1,292 among 1,352 Window series—more insulating than 2.4%.

Does Windsor Windows and Doors Pinnacle Clad Double Hung qualify for the ENERGY STAR Northern Zone?

No. Because Pinnacle Clad Double Hung reaches only 0.27 U-Factor with 0 Northern combinations, it is not approved for ENERGY STAR Northern counties. Specify this Other line strictly across South-Central, Southern cooling or mixed markets.

What conductive BTU/hr difference separates Pinnacle Clad Double Hung from the 0.22 Northern rule?

Using NFRC WIN U-Factor 0.27, a 15 sq ft Double-Hung (VSDH) assembly conducts 162.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+30.0 BTU/hr margin).

What are the practical limitations of specifying Pinnacle Clad Double Hung?

Skip Pinnacle Clad Double Hung if local historic preservation boards prohibit Other profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Pinnacle Clad Double Hung options exceeding U 0.22.

Can you install Windsor Windows and Doors Pinnacle Clad Double Hung in Southern or South-Central zones?

Warm-climate homeowners have 463 Southern-approved options within Pinnacle Clad Double Hung spanning SHGC down to 0.14. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Which package tier in Pinnacle Clad Double Hung holds Most Efficient recognition?

Pinnacle Clad Double Hung holds zero Most Efficient entries across its 463 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

What federal compliance checks govern 2026 Pinnacle Clad Double Hung window swaps?

Any Pinnacle Clad Double Hung purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

Where are NFRC and IGCC identification marks located on Pinnacle Clad Double Hung?

Match the NFRC thermal sticker for code WIN and line WIN-N-116 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Pinnacle Clad Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros