Skip to main content
Window · Composite / Vinyl Frame NFRC AND · Product Line AND-N-192 ENERGY STAR Most Efficient Eligible

Andersen Corporation — 100 Series/Series 2 Fixed/Specialty Overfit Windows · Picture Window

Andersen Corporation engineered the 100 Series/Series 2 Fixed/Specialty Overfit Windows Picture Window line for Northern, North-Central, South-Central, Southern, certifying 4,022 glass-spacer combinations from 0.21 to 0.32 U-Factor and 0.17 to 0.54 SHGC. Relative to other Composite / Vinyl models tracked under NFRC AND, its minimum U-Factor is 0.04 Btu/hr·ft²·°F less insulating than the 0.17 Btu/hr·ft²·°F median.

Min U-Factor
0.21
SHGC Range
0.17-0.54
Certified Options
4,022
Category Standing
#742 of 1,352

How does Andersen Corporation 100 Series/Series 2 Fixed/Specialty Overfit Windows compare thermally against Window peers?

Andersen Corporation 100 Series/Series 2 Fixed/Specialty Overfit Windows achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 100 Series/Series 2 Fixed/Specialty Overfit WindowsHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing 100 Series/Series 2 Fixed/Specialty Overfit Windows (U 0.21).249<=0.153140.16-0.182670.19-0.21This model: U 0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

100 Series/Series 2 Fixed/Specialty Overfit Windows Cohort StandingMin U-Factor 0.21 stands at rank #742 of 1,352, outperforming 38.6% of peers.Min U-Factor 0.21Rank #742 of 1,352 (38.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 100 Series/Series 2 Fixed/Specialty Overfit Windows is 0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Composite / Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.21-0.32.

Mapping NFRC SHGC values (0.17 to 0.54) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 68 configurations meet ENERGY STAR Most Efficient criteria while 405 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2019-01-08 and v7.0 data certification on 2026-09-25. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.21 conducts 126.0 BTU/hr (-6.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 4,022 certified glazing combinations for 100 Series/Series 2 Fixed/Specialty Overfit Windows (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 405 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 925 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 1,826 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 3,398 packages (68 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 100 Series/Series 2 Fixed/Specialty Overfit Windows appear below.

What thermal performance numbers separate Andersen Corporation 100 Series/Series 2 Fixed/Specialty Overfit Windows from peers?

Across 4,022 tested NFRC glazing configurations, Andersen Corporation 100 Series/Series 2 Fixed/Specialty Overfit Windows with Composite / Vinyl framing and Fixed Window (FIXD) style reaches a 0.21 minimum U-Factor and 0.17-0.54 SHGC band. It places #742 among 1,352 Window series—more insulating than 38.6%.

Can homeowners install 100 Series/Series 2 Fixed/Specialty Overfit Windows in cold Northern ENERGY STAR counties?

Yes. 405 packages in Andersen Corporation 100 Series/Series 2 Fixed/Specialty Overfit Windows clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

How do you calculate winter heat conduction for Andersen Corporation 100 Series/Series 2 Fixed/Specialty Overfit Windows?

Using NFRC AND U-Factor 0.21, a 15 sq ft Fixed Window (FIXD) assembly conducts 126.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-6.0 BTU/hr margin).

Which situations make 100 Series/Series 2 Fixed/Specialty Overfit Windows the wrong window or door choice?

Do not specify 100 Series/Series 2 Fixed/Specialty Overfit Windows without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 100 Series/Series 2 Fixed/Specialty Overfit Windows options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Does 100 Series/Series 2 Fixed/Specialty Overfit Windows meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 3,398 Southern-certified options inside Andersen Corporation 100 Series/Series 2 Fixed/Specialty Overfit Windows satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.54 SHGC on west-facing glass to avoid excess afternoon solar gain.

Are all 4,022 100 Series/Series 2 Fixed/Specialty Overfit Windows configurations ENERGY STAR Most Efficient?

Not every package qualifies: 68 of 4,022 100 Series/Series 2 Fixed/Specialty Overfit Windows glazing builds earn Most Efficient recognition (1.7%), while other variants sit on the standard Version 7.0 tier.

Do 2026 100 Series/Series 2 Fixed/Specialty Overfit Windows installations qualify for IRS Section 25C tax credits?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do building inspectors verify 100 Series/Series 2 Fixed/Specialty Overfit Windows glass specs on job sites?

Inspectors match the temporary NFRC sticker (U 0.21-0.32, SHGC 0.17-0.54) against permit drawings for line AND-N-192. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 100 Series/Series 2 Fixed/Specialty Overfit Windows come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)