Andersen Corporation — 100 Series/Series 2 Gliding Window · Single Slider

Andersen Corporation engineered the 100 Series/Series 2 Gliding Window Single Slider line for Northern, North-Central, South-Central, Southern, certifying 7,061 glass-spacer combinations from 0.25 to 0.32 U-Factor and 0.15 to 0.48 SHGC. Relative to other Composite models tracked under NFRC AND, its minimum U-Factor is 0.03 Btu/hr·ft²·°F less insulating than the 0.22 Btu/hr·ft²·°F median.

Min U-Factor
0.25
SHGC Range
0.15-0.48
Certified Options
7,061
Category Standing
#1,174 of 1,352

How does Andersen Corporation 100 Series/Series 2 Gliding Window compare thermally against Window peers?

Andersen Corporation 100 Series/Series 2 Gliding Window achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 100 Series/Series 2 Gliding WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing 100 Series/Series 2 Gliding Window (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

100 Series/Series 2 Gliding Window Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 111 certified Andersen Corporation series, this Single Slider offers a 0.07 U-Factor adjustment span between 0.32 entry options and 0.25 top-performing glazing. Category standing is #1,174/1,352 (tied with 81 others at 0.25, more insulating than 7.2% of Window lines).

Mapping NFRC SHGC values (0.15 to 0.48) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 60 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Registry history records EPA FENSTAR licensing on 2019-01-08 and v7.0 data certification on 2025-09-18. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.25 conducts 150.0 BTU/hr (+18.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 7,061 certified glazing combinations for 100 Series/Series 2 Gliding Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 60 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 62 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 1,355 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 7,001 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 100 Series/Series 2 Gliding Window appear below.

How well does 100 Series/Series 2 Gliding Window by Andersen Corporation insulate relative to Window benchmarks?

Across 7,061 tested NFRC glazing configurations, Andersen Corporation 100 Series/Series 2 Gliding Window with Composite framing and Horizontal Slider (HSOX) style reaches a 0.25 minimum U-Factor and 0.15-0.48 SHGC band. It places #1,174 among 1,352 Window series—more insulating than 7.2%.

Does Andersen Corporation 100 Series/Series 2 Gliding Window qualify for the ENERGY STAR Northern Zone?

While Andersen Corporation 100 Series/Series 2 Gliding Window misses the <= 0.22 prescriptive mark (floor U 0.25), 60 packages still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.

How much winter heat loss does 100 Series/Series 2 Gliding Window conduct across a 15 sq ft opening?

Using NFRC AND U-Factor 0.25, a 15 sq ft Horizontal Slider (HSOX) assembly conducts 150.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+18.0 BTU/hr margin).

What are the practical limitations of specifying 100 Series/Series 2 Gliding Window?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 100 Series/Series 2 Gliding Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

How many 100 Series/Series 2 Gliding Window glazing packages pass Southern solar-heat rules?

Yes, 100 Series/Series 2 Gliding Window holds 7,001 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.15 SHGC in cooling climates.

Does 100 Series/Series 2 Gliding Window carry EPA Most Efficient certification across its lineup?

Zero glazing builds inside 100 Series/Series 2 Gliding Window's 7,061 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

What federal compliance checks govern 2026 100 Series/Series 2 Gliding Window window swaps?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 100 Series/Series 2 Gliding Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

What permanent glass etch marks verify 100 Series/Series 2 Gliding Window after sticker removal?

Inspectors match the temporary NFRC sticker (U 0.25-0.32, SHGC 0.15-0.48) against permit drawings for line AND-N-81. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 100 Series/Series 2 Gliding Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros