Skip to main content
Window · Wood Frame NFRC AND · Product Line AND-N-95

Andersen Corporation — A-Series Frenchwood® Patio Door Transom - Sash-Set · Transom

Andersen Corporation engineered the A-Series Frenchwood® Patio Door Transom - Sash-Set Transom line for North-Central, South-Central, Southern, certifying 3,861 glass-spacer combinations from 0.23 to 0.32 U-Factor and 0.11 to 0.33 SHGC. Relative to other Wood models tracked under NFRC AND, its minimum U-Factor is 0.02 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.23
SHGC Range
0.11-0.33
Certified Options
3,861
Category Standing
#936 of 1,352

How does Andersen Corporation A-Series Frenchwood® Patio Door Transom - Sash-Set compare thermally against Window peers?

Andersen Corporation A-Series Frenchwood® Patio Door Transom - Sash-Set achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. A-Series Frenchwood® Patio Door Transom - Sash-SetHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing A-Series Frenchwood® Patio Door Transom - Sash-Set (U 0.23).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.231460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

A-Series Frenchwood® Patio Door Transom - Sash-Set Cohort StandingMin U-Factor 0.23 stands at rank #936 of 1,352, outperforming 23.6% of peers.Min U-Factor 0.23Rank #936 of 1,352 (23.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Andersen Corporation A-Series Frenchwood® Patio Door Transom - Sash-Set standing at #936 of 1,352 certified Window product series, tied with 97 others at 0.23, more insulating than 23.6% of Window lines. Comparing Wood profiles alone (median 0.21) shows +0.02 before selecting Low-E tiers.

Mapping NFRC SHGC values (0.11 to 0.33) against ENERGY STAR Version 7.0 targets approves North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.11 lowers cooling load.

Lifecycle documentation anchors AND to 2024-03-07 certification (FENSTAR issued 2019-01-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 138.0 BTU/hr conductive loss (+4.5% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,861 certified glazing combinations for A-Series Frenchwood® Patio Door Transom - Sash-Set (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 128 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 852 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 3,829 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation A-Series Frenchwood® Patio Door Transom - Sash-Set appear below.

What U-Factor and SHGC range does Andersen Corporation A-Series Frenchwood® Patio Door Transom - Sash-Set achieve?

EPA ENERGY STAR v7.0 records 3,861 configurations for Andersen Corporation A-Series Frenchwood® Patio Door Transom - Sash-Set covering North-Central, South-Central, Southern, dropping down to U 0.23 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Can homeowners install A-Series Frenchwood® Patio Door Transom - Sash-Set in cold Northern ENERGY STAR counties?

Northern Zone certification is absent for A-Series Frenchwood® Patio Door Transom - Sash-Set (0 qualifying options, min U 0.23). Install this Fixed Transom (FXTR) product only within North-Central, South-Central, Southern regions where lower SHGC caps apply.

How do you calculate winter heat conduction for Andersen Corporation A-Series Frenchwood® Patio Door Transom - Sash-Set?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 138.0 BTU/hr on A-Series Frenchwood® Patio Door Transom - Sash-Set's lowest-U package (0.23), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

Which situations make A-Series Frenchwood® Patio Door Transom - Sash-Set the wrong window or door choice?

Do not specify A-Series Frenchwood® Patio Door Transom - Sash-Set without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on A-Series Frenchwood® Patio Door Transom - Sash-Set options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Can you install Andersen Corporation A-Series Frenchwood® Patio Door Transom - Sash-Set in Southern or South-Central zones?

Across North-Central, South-Central, Southern, 3,829 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Andersen Corporation A-Series Frenchwood® Patio Door Transom - Sash-Set, while total line SHGC reaches 0.33 in colder packages.

What glazing share inside A-Series Frenchwood® Patio Door Transom - Sash-Set qualifies as Most Efficient?

A-Series Frenchwood® Patio Door Transom - Sash-Set holds zero Most Efficient entries across its 3,861 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

How do the 25C sunset and pre-1978 Lead RRP rules affect A-Series Frenchwood® Patio Door Transom - Sash-Set?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

Where are NFRC and IGCC identification marks located on A-Series Frenchwood® Patio Door Transom - Sash-Set?

Inspectors match the temporary NFRC sticker (U 0.23-0.32, SHGC 0.11-0.33) against permit drawings for line AND-N-95. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation A-Series Frenchwood® Patio Door Transom - Sash-Set come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros