Window · Wood Frame NFRC AND · Product Line AND-N-179

Andersen Corporation — E-Series Awning/Push Out Awning Windows · Awning (Projected)

Andersen Corporation engineered the E-Series Awning/Push Out Awning Windows Awning, Projected line for Northern, North-Central, South-Central, Southern, certifying 3,764 glass-spacer combinations from 0.23 to 0.32 U-Factor and 0.13 to 0.39 SHGC. Relative to other Wood models tracked under NFRC AND, its minimum U-Factor is 0.02 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.23
SHGC Range
0.13-0.39
Certified Options
3,764
Category Standing
#936 of 1,352

How does Andersen Corporation E-Series Awning/Push Out Awning Windows compare thermally against Window peers?

Andersen Corporation E-Series Awning/Push Out Awning Windows achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. E-Series Awning/Push Out Awning WindowsHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing E-Series Awning/Push Out Awning Windows (U 0.23).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.231460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

E-Series Awning/Push Out Awning Windows Cohort StandingMin U-Factor 0.23 stands at rank #936 of 1,352, outperforming 23.6% of peers.Min U-Factor 0.23Rank #936 of 1,352 (23.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Andersen Corporation E-Series Awning/Push Out Awning Windows standing at #936 of 1,352 certified Window product series, tied with 97 others at 0.23, more insulating than 23.6% of Window lines. Comparing Wood profiles alone (median 0.21) shows +0.02 before selecting Low-E tiers.

Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 4 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Registry history records EPA FENSTAR licensing on 2019-01-08 and v7.0 data certification on 2026-03-12. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.23 conducts 138.0 BTU/hr (+6.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,764 certified glazing combinations for E-Series Awning/Push Out Awning Windows (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 4 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 280 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 782 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 3,672 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation E-Series Awning/Push Out Awning Windows appear below.

What thermal performance numbers separate Andersen Corporation E-Series Awning/Push Out Awning Windows from peers?

Across 3,764 tested NFRC glazing configurations, Andersen Corporation E-Series Awning/Push Out Awning Windows with Wood framing and Projected Awning (PRAW) style reaches a 0.23 minimum U-Factor and 0.13-0.39 SHGC band. It places #936 among 1,352 Window series—more insulating than 23.6%.

Can homeowners install E-Series Awning/Push Out Awning Windows in cold Northern ENERGY STAR counties?

Because E-Series Awning/Push Out Awning Windows starts at 0.23 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 4 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).

What BTU/hr heat transfer results from E-Series Awning/Push Out Awning Windows's 0.23 minimum U-Factor?

Using NFRC AND U-Factor 0.23, a 15 sq ft Projected Awning (PRAW) assembly conducts 138.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+6.0 BTU/hr margin).

What are the practical limitations of specifying E-Series Awning/Push Out Awning Windows?

Do not specify E-Series Awning/Push Out Awning Windows without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on E-Series Awning/Push Out Awning Windows options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Does E-Series Awning/Push Out Awning Windows meet Southern hot-climate SHGC caps (<= 0.23)?

Warm-climate homeowners have 3,672 Southern-approved options within E-Series Awning/Push Out Awning Windows spanning SHGC down to 0.13. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Are all 3,764 E-Series Awning/Push Out Awning Windows configurations ENERGY STAR Most Efficient?

All 3,764 E-Series Awning/Push Out Awning Windows listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

Do 2026 E-Series Awning/Push Out Awning Windows installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 E-Series Awning/Push Out Awning Windows installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

Where are NFRC and IGCC identification marks located on E-Series Awning/Push Out Awning Windows?

Confirm both the paper NFRC label and permanent corner glass etch match line AND-N-179 and NFRC ID AND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation E-Series Awning/Push Out Awning Windows come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros