Skip to main content
Window · Wood Frame NFRC AND · Product Line AND-N-171

Andersen Corporation — E-Series Double-Hung Window - Full Frame · Double Hung

Positioning #936/1,352 in certified Window, Andersen Corporation E-Series Double-Hung Window - Full Frame pairs Wood frame construction with 6,710 glazing options rated between 0.09 and 0.41 SHGC across Northern, North-Central, South-Central, Southern. Across 111 certified Andersen Corporation product families, its thermal resistance spans 0.23 to 0.32 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.23
SHGC Range
0.09-0.41
Certified Options
6,710
Category Standing
#936 of 1,352

How does Andersen Corporation E-Series Double-Hung Window - Full Frame compare thermally against Window peers?

Andersen Corporation E-Series Double-Hung Window - Full Frame achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. E-Series Double-Hung Window - Full FrameHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing E-Series Double-Hung Window - Full Frame (U 0.23).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.231460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

E-Series Double-Hung Window - Full Frame Cohort StandingMin U-Factor 0.23 stands at rank #936 of 1,352, outperforming 23.6% of peers.Min U-Factor 0.23Rank #936 of 1,352 (23.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Andersen Corporation E-Series Double-Hung Window - Full Frame at rank #936 of 1,352 (tied with 97 others at 0.23, more insulating than 23.6% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.09-0.41 band.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 16 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2025-03-12 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 138.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 6,710 certified glazing combinations for E-Series Double-Hung Window - Full Frame (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 16 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 170 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 1,247 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 6,652 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Marvin — Ultimate Glider Picture Wood 0.23 0.11 2,132
Marvin — Ultimate Wood Double Hung Picture 1 5/8 inch Sash Wood 0.23 0.11 1,700
Marvin — Ultimate Casement Push Out Wood 0.23 0.10 12,297
Windsor Windows and Doors — Legend Double Hung Transom Wood 0.23 0.10 777
JELD-WEN, inc. — Custom Clad Casement Wood 0.23 0.11 774

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation E-Series Double-Hung Window - Full Frame appear below.

How efficient is Andersen Corporation E-Series Double-Hung Window - Full Frame compared with peer Window models?

Built with Wood framing in Double-Hung (VSDH) style, Andersen Corporation E-Series Double-Hung Window - Full Frame offers 6,710 Version 7.0 configurations from U 0.23 up to 0.32, posting +0.03 against the Window median of 0.20 with 0 Most Efficient picks.

Does Andersen Corporation E-Series Double-Hung Window - Full Frame qualify for the ENERGY STAR Northern Zone?

With a 0.23 minimum U-Factor, Andersen Corporation E-Series Double-Hung Window - Full Frame cannot satisfy prescriptive <= 0.22 Northern targets, yet 16 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

What BTU/hr heat transfer results from E-Series Double-Hung Window - Full Frame's 0.23 minimum U-Factor?

At U 0.23, a standard 3x5 ft (15 sq ft) E-Series Double-Hung Window - Full Frame opening transfers 138.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +6.0 BTU/hr difference.

Which situations make E-Series Double-Hung Window - Full Frame the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on E-Series Double-Hung Window - Full Frame options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Is E-Series Double-Hung Window - Full Frame suitable for sunbelt cooling-dominated homes?

Exactly 6,652 E-Series Double-Hung Window - Full Frame options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.09 rather than higher 0.41 glass.

What glazing share inside E-Series Double-Hung Window - Full Frame qualifies as Most Efficient?

E-Series Double-Hung Window - Full Frame holds zero Most Efficient entries across its 6,710 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

Can homeowners claim Form 5695 credits on Andersen Corporation E-Series Double-Hung Window - Full Frame in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 E-Series Double-Hung Window - Full Frame installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

Where are NFRC and IGCC identification marks located on E-Series Double-Hung Window - Full Frame?

Verify NFRC ID AND and series AND-N-171 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation E-Series Double-Hung Window - Full Frame come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros