Skip to main content
Window · Composite Frame NFRC AND · Product Line AND-N-236

Andersen Corporation — Renewal by Andersen® Entry Door – Direct Set Sidelight · Sidelite

EPA ENERGY STAR Version 7.0 certifies 1,048 variants inside Andersen Corporation Renewal by Andersen® Entry Door – Direct Set Sidelight, combining Composite frame construction with U-Factors spanning 0.19 to 0.28 and SHGC 0.15 to 0.40. Qualifying for Northern, North-Central, South-Central, Southern, this Sidelite family places #564 of 1,352 among 1,352 Window families and posts 0.03 Btu/hr·ft²·°F more insulating than the 0.22 Btu/hr·ft²·°F median among Composite peers.

Min U-Factor
0.19
SHGC Range
0.15-0.40
Certified Options
1,048
Category Standing
#564 of 1,352

How does Andersen Corporation Renewal by Andersen® Entry Door – Direct Set Sidelight compare thermally against Window peers?

Andersen Corporation Renewal by Andersen® Entry Door – Direct Set Sidelight achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Renewal by Andersen® Entry Door – Direct Set SidelightHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Renewal by Andersen® Entry Door – Direct Set Sidelight (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Renewal by Andersen® Entry Door – Direct Set Sidelight Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Renewal by Andersen® Entry Door – Direct Set Sidelight spans 1,048 NFRC test records (AND), ranking #564 of 1,352 Window families (tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%). Its 0.19 thermal floor compares at -0.03 against the Composite median (0.22).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 890 combinations qualify in the Northern Zone alongside 668 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Lifecycle documentation anchors AND to 2024-03-05 certification (FENSTAR issued 2019-01-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 114.0 BTU/hr conductive loss (-13.6% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,048 certified glazing combinations for Renewal by Andersen® Entry Door – Direct Set Sidelight (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 890 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 890 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 668 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 668 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation Renewal by Andersen® Entry Door – Direct Set Sidelight appear below.

What U-Factor and SHGC range does Andersen Corporation Renewal by Andersen® Entry Door – Direct Set Sidelight achieve?

Testing puts Andersen Corporation Renewal by Andersen® Entry Door – Direct Set Sidelight at rank #564 of 1,352 Window entries with U 0.19 to 0.28 across 1,048 configurations. Solar heat gain ranges between 0.15 and 0.40 across Northern, North-Central, South-Central, Southern.

Does Andersen Corporation Renewal by Andersen® Entry Door – Direct Set Sidelight qualify for the ENERGY STAR Northern Zone?

Cold-climate buyers get 890 compliant Northern packages inside Renewal by Andersen® Entry Door – Direct Set Sidelight, reaching down to U 0.19. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.28 options.

How does a 3x5 ft Renewal by Andersen® Entry Door – Direct Set Sidelight window perform under a 40 deg F temperature drop?

Using NFRC AND U-Factor 0.19, a 15 sq ft Fixed Sidelite (FXSL) assembly conducts 114.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-18.0 BTU/hr margin).

Who should NOT choose Andersen Corporation Renewal by Andersen® Entry Door – Direct Set Sidelight for a residential project?

Do not specify Renewal by Andersen® Entry Door – Direct Set Sidelight without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Renewal by Andersen® Entry Door – Direct Set Sidelight options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Can you install Andersen Corporation Renewal by Andersen® Entry Door – Direct Set Sidelight in Southern or South-Central zones?

Warm-climate homeowners have 668 Southern-approved options within Renewal by Andersen® Entry Door – Direct Set Sidelight spanning SHGC down to 0.15. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Are all 1,048 Renewal by Andersen® Entry Door – Direct Set Sidelight configurations ENERGY STAR Most Efficient?

Renewal by Andersen® Entry Door – Direct Set Sidelight holds zero Most Efficient entries across its 1,048 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

Can homeowners claim Form 5695 credits on Andersen Corporation Renewal by Andersen® Entry Door – Direct Set Sidelight in 2026?

Any Renewal by Andersen® Entry Door – Direct Set Sidelight purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How can homeowners confirm delivered Andersen Corporation Renewal by Andersen® Entry Door – Direct Set Sidelight units match permits?

Confirm both the paper NFRC label and permanent corner glass etch match line AND-N-236 and NFRC ID AND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation Renewal by Andersen® Entry Door – Direct Set Sidelight come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros