Window · Vinyl Frame NFRC IBM · Product Line IBM-K-56

Interstate Building Materials, Inc. — 145/5000/5100/5200 Double Hung · Double Hung

EPA ENERGY STAR Version 7.0 certifies 136 variants inside Interstate Building Materials, Inc. 145/5000/5100/5200 Double Hung, combining Vinyl frame construction with U-Factors spanning 0.23 to 0.30 and SHGC 0.18 to 0.50. Qualifying for Northern, North-Central, South-Central, Southern, this Double Hung family places #936 of 1,352 among 1,352 Window families and posts 0.04 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.23
SHGC Range
0.18-0.50
Certified Options
136
Category Standing
#936 of 1,352

How does Interstate Building Materials, Inc. 145/5000/5100/5200 Double Hung compare thermally against Window peers?

Interstate Building Materials, Inc. 145/5000/5100/5200 Double Hung achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 145/5000/5100/5200 Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 145/5000/5100/5200 Double Hung (U 0.23).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.231460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

145/5000/5100/5200 Double Hung Cohort StandingMin U-Factor 0.23 stands at rank #936 of 1,352, outperforming 23.6% of peers.Min U-Factor 0.23Rank #936 of 1,352 (23.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), 145/5000/5100/5200 Double Hung reaches 0.23 on its lowest-conductivity package — #716 of 1,009 in Vinyl, tied with 81 others at 0.23, more insulating than 21.0% of Vinyl lines (+0.04 vs Vinyl peers). Pairing NFRC ID IBM across multi-pane fills shifts U-Factor from 0.30 down toward 0.23.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 30 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 138.0 BTU/hr (+4.5% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-09-05 and cert timestamp 2024-06-20.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 136 certified glazing combinations for 145/5000/5100/5200 Double Hung (NFRC IBM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 30 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 60 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 69 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 76 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Interstate Building Materials, Inc. produce?

Compare other active Interstate Building Materials, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Interstate Building Materials, Inc. 145/5000/5100/5200 Double Hung appear below.

Where does Interstate Building Materials, Inc. 145/5000/5100/5200 Double Hung stand thermally among ENERGY STAR Window lines?

Testing puts Interstate Building Materials, Inc. 145/5000/5100/5200 Double Hung at rank #936 of 1,352 Window entries with U 0.23 to 0.30 across 136 configurations. Solar heat gain ranges between 0.18 and 0.50 across Northern, North-Central, South-Central, Southern.

Is 145/5000/5100/5200 Double Hung approved for Northern Zone heating climates?

Northern qualification on 145/5000/5100/5200 Double Hung relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.23. Exactly 30 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.

How does a 3x5 ft 145/5000/5100/5200 Double Hung window perform under a 40 deg F temperature drop?

Using NFRC IBM U-Factor 0.23, a 15 sq ft Double-Hung (VSDH) assembly conducts 138.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+6.0 BTU/hr margin).

Who should NOT choose Interstate Building Materials, Inc. 145/5000/5100/5200 Double Hung for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 145/5000/5100/5200 Double Hung options exceeding U 0.22. Additionally, do not order Double-Hung (VSDH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is 145/5000/5100/5200 Double Hung suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 76 Southern-approved options within 145/5000/5100/5200 Double Hung spanning SHGC down to 0.18. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

What glazing share inside 145/5000/5100/5200 Double Hung qualifies as Most Efficient?

All 136 145/5000/5100/5200 Double Hung listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

What federal compliance checks govern 2026 145/5000/5100/5200 Double Hung window swaps?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Interstate Building Materials, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do building inspectors verify 145/5000/5100/5200 Double Hung glass specs on job sites?

Verify NFRC ID IBM and series IBM-K-56 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Interstate Building Materials, Inc. 145/5000/5100/5200 Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros