Lincoln Wood Products, Inc. — Lincoln Fit Awning · Awning (Projected)
EPA ENERGY STAR Version 7.0 certifies 38 variants inside Lincoln Wood Products, Inc. Lincoln Fit Awning, combining Other frame with Wood sash with U-Factors spanning 0.28 to 0.32 and SHGC 0.16 to 0.23. Qualifying for South-Central, Southern, this Awning, Projected family places #1,320 of 1,352 among 1,352 Window families and posts 0.03 Btu/hr·ft²·°F less insulating than the 0.25 Btu/hr·ft²·°F median among Other peers.
- Min U-Factor
- 0.28
- SHGC Range
- 0.16-0.23
- Certified Options
- 38
- Category Standing
- #1,320 of 1,352
How does Lincoln Wood Products, Inc. Lincoln Fit Awning compare thermally against Window peers?
Lincoln Wood Products, Inc. Lincoln Fit Awning achieves a 0.28 thermal floor across Window lines, placing #1,320 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 18 certified Lincoln Wood Products, Inc. series, this Awning, Projected offers a 0.04 U-Factor adjustment span between 0.32 entry options and 0.28 top-performing glazing. Category standing is #1,320/1,352 (tied with 23 others at 0.28, more insulating than 0.7% of Window lines).
Evaluating climate compliance across South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.16 lowers cooling load.
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 168.0 BTU/hr (+27.3% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-02-29.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 38 certified glazing combinations for Lincoln Fit Awning (NFRC TVW) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| North-Central | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 7 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 38 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.28 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| All America Windows LLC — 1900 Series Single Hung | Vinyl | 0.28 | 0.19 | 36 |
| L.A.S. Enterprises — Weathergard II - Vinyl Single Hung | Vinyl | 0.28 | 0.14 | 60 |
| Duke Vinyl Windows — Marquis Double Hung | Vinyl | 0.28 | 0.19 | 12 |
| Duke Vinyl Windows — Marquis Horizontal Slider | Vinyl | 0.28 | 0.19 | 12 |
| Phos Window — 1400 Picture Window | Vinyl | 0.28 | 0.21 | 8 |
What other certified series does Lincoln Wood Products, Inc. produce?
Compare other active Lincoln Wood Products, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Clad Casement Studio (Transom) - Crank-Out & Push-Out
U-Factor 0.19–0.32 · 598 certified options.
Clad Casement - Crank-Out & Push-Out
U-Factor 0.20–0.32 · 217 certified options.
Clad Awning - Push-Out & Crank-Out
U-Factor 0.21–0.32 · 204 certified options.
Clad Hybrid Casement Studio (Transom) - Crank-Out & Push-Out
U-Factor 0.24–0.32 · 137 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Lincoln Wood Products, Inc. Lincoln Fit Awning appear below.
How efficient is Lincoln Wood Products, Inc. Lincoln Fit Awning compared with peer Window models?
Testing puts Lincoln Wood Products, Inc. Lincoln Fit Awning at rank #1,320 of 1,352 Window entries with U 0.28 to 0.32 across 38 configurations. Solar heat gain ranges between 0.16 and 0.23 across South-Central, Southern.
Is Lincoln Fit Awning approved for Northern Zone heating climates?
This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.28). Focus on South-Central, Southern glazing applications where SHGC 0.16-0.23 manages cooling loads.
How do you calculate winter heat conduction for Lincoln Wood Products, Inc. Lincoln Fit Awning?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.28 U-Factor yields 168.0 BTU/hr conductive transfer (+27.3% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
Which situations make Lincoln Fit Awning the wrong window or door choice?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Lincoln Fit Awning options exceeding U 0.22. Additionally, do not order Projected Awning (PRAW) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
How many Lincoln Fit Awning glazing packages pass Southern solar-heat rules?
Yes, Lincoln Fit Awning holds 38 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.16 SHGC in cooling climates.
Does Lincoln Fit Awning carry EPA Most Efficient certification across its lineup?
Lincoln Fit Awning holds zero Most Efficient entries across its 38 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.
How do the 25C sunset and pre-1978 Lead RRP rules affect Lincoln Fit Awning?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
Where are NFRC and IGCC identification marks located on Lincoln Fit Awning?
Verify NFRC ID TVW and series TVW-A-174 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Lincoln Wood Products, Inc. Lincoln Fit Awning come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)