Lincoln Wood Products, Inc. — Wood Casement - Crank-Out & Push-Out · Casement Windows
Across 18 Lincoln Wood Products, Inc. certified families, Wood Casement - Crank-Out & Push-Out supplies 44 Casement Windows configurations starting at 0.26 U-Factor and 0.15 SHGC for South-Central, Southern, reaching up to 0.32 U-Factor and 0.23 SHGC. Its thermal floor ranks #1,256 of 1,352 category entries—0.06 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.26
- SHGC Range
- 0.15-0.23
- Certified Options
- 44
- Category Standing
- #1,256 of 1,352
How does Lincoln Wood Products, Inc. Wood Casement - Crank-Out & Push-Out compare thermally against Window peers?
Lincoln Wood Products, Inc. Wood Casement - Crank-Out & Push-Out achieves a 0.26 thermal floor across Window lines, placing #1,256 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Relative to Window assemblies nationwide (median U 0.20), Wood Casement - Crank-Out & Push-Out is 0.06 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Other frame with Wood sash. Selecting different glass and gas-fill packages moves thermal performance along 0.26-0.32.
Evaluating climate compliance across South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.15 lowers cooling load.
Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2024-04-05. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.26 conducts 156.0 BTU/hr (+24.0 BTU/hr vs the 0.22 ceiling).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 44 certified glazing combinations for Wood Casement - Crank-Out & Push-Out (NFRC TVW) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| North-Central | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 14 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 44 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| REHAU, S.A. DE C.V. — S190 Single Slider | Vinyl | 0.26 | 0.14 | 44 |
| Marvin — Essential Casement | Fiberglass | 0.26 | 0.18 | 37 |
| Comfort View Products, LLC — 1920 Horizontal Slider | Vinyl | 0.26 | 0.20 | 33 |
| Harvey Industries, Inc. — Majesty Casement Window | Wood | 0.26 | 0.16 | 59 |
| Value Windows & Doors — AUC-XO Horizontal Slider | Aluminum | 0.26 | 0.13 | 20 |
What other certified series does Lincoln Wood Products, Inc. produce?
Compare other active Lincoln Wood Products, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Clad Casement Studio (Transom) - Crank-Out & Push-Out
U-Factor 0.19–0.32 · 598 certified options.
Clad Casement - Crank-Out & Push-Out
U-Factor 0.20–0.32 · 217 certified options.
Clad Awning - Push-Out & Crank-Out
U-Factor 0.21–0.32 · 204 certified options.
Clad Hybrid Casement Studio (Transom) - Crank-Out & Push-Out
U-Factor 0.24–0.32 · 137 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Lincoln Wood Products, Inc. Wood Casement - Crank-Out & Push-Out appear below.
How well does Wood Casement - Crank-Out & Push-Out by Lincoln Wood Products, Inc. insulate relative to Window benchmarks?
Testing puts Lincoln Wood Products, Inc. Wood Casement - Crank-Out & Push-Out at rank #1,256 of 1,352 Window entries with U 0.26 to 0.32 across 44 configurations. Solar heat gain ranges between 0.15 and 0.23 across South-Central, Southern.
Can homeowners install Wood Casement - Crank-Out & Push-Out in cold Northern ENERGY STAR counties?
Lincoln Wood Products, Inc. Wood Casement - Crank-Out & Push-Out holds zero Northern Zone qualifications (min U 0.26). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.
What BTU/hr heat transfer results from Wood Casement - Crank-Out & Push-Out's 0.26 minimum U-Factor?
At U 0.26, a standard 3x5 ft (15 sq ft) Wood Casement - Crank-Out & Push-Out opening transfers 156.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +24.0 BTU/hr difference.
What homeowner profiles are a poor match for Lincoln Wood Products, Inc. Wood Casement - Crank-Out & Push-Out?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Wood Casement - Crank-Out & Push-Out options exceeding U 0.22. Verify whether your municipal code restricts Other frames in wildfire or historic zones.
Is Wood Casement - Crank-Out & Push-Out suitable for sunbelt cooling-dominated homes?
Across South-Central, Southern, 44 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Lincoln Wood Products, Inc. Wood Casement - Crank-Out & Push-Out, while total line SHGC reaches 0.23 in colder packages.
Which package tier in Wood Casement - Crank-Out & Push-Out holds Most Efficient recognition?
No. Zero of the 44 configurations in Lincoln Wood Products, Inc. Wood Casement - Crank-Out & Push-Out hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.
How do the 25C sunset and pre-1978 Lead RRP rules affect Wood Casement - Crank-Out & Push-Out?
Any Wood Casement - Crank-Out & Push-Out purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
What permanent glass etch marks verify Wood Casement - Crank-Out & Push-Out after sticker removal?
Inspectors match the temporary NFRC sticker (U 0.26-0.32, SHGC 0.15-0.23) against permit drawings for line TVW-A-164. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Lincoln Wood Products, Inc. Wood Casement - Crank-Out & Push-Out come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)