Simonton Building Products, Inc. - Simonton Windows — 43-40 / 43-45 Double Hung · Double Hung
With a minimum U-Factor of 0.24—+0.04 compared against the 0.20 Window median—Simonton Building Products, Inc. - Simonton Windows 43-40 / 43-45 Double Hung spans 3,341 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code SBP, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.11 and 0.48.
- Min U-Factor
- 0.24
- SHGC Range
- 0.11-0.48
- Certified Options
- 3,341
- Category Standing
- #1,034 of 1,352
How does Simonton Building Products, Inc. - Simonton Windows 43-40 / 43-45 Double Hung compare thermally against Window peers?
Simonton Building Products, Inc. - Simonton Windows 43-40 / 43-45 Double Hung achieves a 0.24 thermal floor across Window lines, placing #1,034 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Simonton Building Products, Inc. - Simonton Windows 43-40 / 43-45 Double Hung at rank #1,034 of 1,352 (tied with 139 others at 0.24, more insulating than 13.2% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.11-0.48 band.
Mapping NFRC SHGC values (0.11 to 0.48) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.24 floor sits above the 0.22 prescriptive Northern ceiling, 158 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 144.0 BTU/hr (+9.1% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-08-23 and cert timestamp 2025-02-12.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 3,341 certified glazing combinations for 43-40 / 43-45 Double Hung (NFRC SBP) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 158 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 344 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 1,237 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 3,060 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.24 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Associated Materials, Inc. — A272/A273 Horizontal Slider | Vinyl | 0.24 | 0.09 | 3,548 |
| Wincore Window Company, LLC — Series 400, 500, 5400 Double Slider | Vinyl | 0.24 | 0.12 | 3,047 |
| Associated Materials, Inc. — A571 Single Hung | Vinyl | 0.24 | 0.09 | 3,722 |
| Milgard Manufacturing, Inc. — 6210.6211.6230.6230J.6270 Single Hung | Vinyl | 0.24 | 0.11 | 3,934 |
| Milgard Manufacturing, Inc. — 6110.6111.6130.6130J.6170 Horizontal Slider | Vinyl | 0.24 | 0.11 | 3,950 |
What other certified series does Simonton Building Products, Inc. - Simonton Windows produce?
Compare other active Simonton Building Products, Inc. - Simonton Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
07-09 / 07-10 / 07-20 / 07-75 PW
U-Factor 0.14–0.32 · 52,166 certified options.
07-09 / 07-10 / 07-20 / 07-75 / 75-09 / 75-10 / 75-20 DH
U-Factor 0.17–0.32 · 43,036 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Simonton Building Products, Inc. - Simonton Windows 43-40 / 43-45 Double Hung appear below.
What U-Factor and SHGC range does Simonton Building Products, Inc. - Simonton Windows 43-40 / 43-45 Double Hung achieve?
Simonton Building Products, Inc. - Simonton Windows 43-40 / 43-45 Double Hung spans 3,341 certified configurations with U-Factors between 0.24 and 0.32 and SHGC values from 0.11 to 0.48. Ranked #1,034 of 1,352 Window families, it carries 0 Most Efficient options.
How does Simonton Building Products, Inc. - Simonton Windows 43-40 / 43-45 Double Hung satisfy Version 7.0 Northern criteria?
While Simonton Building Products, Inc. - Simonton Windows 43-40 / 43-45 Double Hung misses the <= 0.22 prescriptive mark (floor U 0.24), 158 packages still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.
How does a 3x5 ft 43-40 / 43-45 Double Hung window perform under a 40 deg F temperature drop?
At U 0.24, a standard 3x5 ft (15 sq ft) 43-40 / 43-45 Double Hung opening transfers 144.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +12.0 BTU/hr difference.
Which situations make 43-40 / 43-45 Double Hung the wrong window or door choice?
Do not specify 43-40 / 43-45 Double Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 43-40 / 43-45 Double Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
What Southern ENERGY STAR v7.0 options exist in 43-40 / 43-45 Double Hung?
Yes. 3,060 Southern-certified options inside Simonton Building Products, Inc. - Simonton Windows 43-40 / 43-45 Double Hung satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.48 SHGC on west-facing glass to avoid excess afternoon solar gain.
How many Simonton Building Products, Inc. - Simonton Windows 43-40 / 43-45 Double Hung variants earn ENERGY STAR Most Efficient?
ENERGY STAR Most Efficient designation is absent across all 3,341 43-40 / 43-45 Double Hung options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.
What 2026 federal tax credit and Lead RRP rules apply to 43-40 / 43-45 Double Hung?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 Simonton Building Products, Inc. - Simonton Windows upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
How can homeowners confirm delivered Simonton Building Products, Inc. - Simonton Windows 43-40 / 43-45 Double Hung units match permits?
Inspectors match the temporary NFRC sticker (U 0.24-0.32, SHGC 0.11-0.48) against permit drawings for line SBP-A-47. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Simonton Building Products, Inc. - Simonton Windows 43-40 / 43-45 Double Hung come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)