Skip to main content
Window · Vinyl Frame NFRC WCW · Product Line WCW-M-38 ENERGY STAR Most Efficient Eligible

Wincore Window Company, LLC — 7700, 9900 Basement Window · Awning (Projected)

Wincore Window Company, LLC 7700, 9900 Basement Window is a Awning, Projected assembly with a Vinyl frame that reaches a minimum U-Factor of 0.17 across 6,256 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #362 of 1,352 in Window, its thermal floor is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.08 to 0.41.

Min U-Factor
0.17
SHGC Range
0.08-0.41
Certified Options
6,256
Category Standing
#362 of 1,352

How does Wincore Window Company, LLC 7700, 9900 Basement Window compare thermally against Window peers?

Wincore Window Company, LLC 7700, 9900 Basement Window achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 7700, 9900 Basement WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 7700, 9900 Basement Window (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

7700, 9900 Basement Window Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Wincore Window Company, LLC 7700, 9900 Basement Window at rank #362 of 1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.08-0.41 band.

Mapping NFRC SHGC values (0.08 to 0.41) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 458 configurations meet ENERGY STAR Most Efficient criteria while 416 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.17 U-Factor yields 102.0 BTU/hr transfer (-30.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-08-23 licensing and 2024-12-16 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 6,256 certified glazing combinations for 7700, 9900 Basement Window (NFRC WCW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 416 packages (24 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 2,654 packages (134 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 4,915 packages (122 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 5,928 packages (446 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Vinylmax LLC — DHA4 Double Hung Vinyl 0.17 0.14 7,745
PGT Industries — HR5410/5510 Vinyl 0.17 0.08 8,277
MI Windows and Doors, LLC — SR SH | DH SP Vinyl Fixed Specialty Window Vinyl 0.17 0.09 4,152
PGT Industries — SH5400/5500 Vinyl 0.17 0.09 9,241
Amsco Windows — VZ1 Hampton PM Fixed Vinyl 0.17 0.11 2,764

What other certified series does Wincore Window Company, LLC produce?

Compare other active Wincore Window Company, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Wincore Window Company, LLC 7700, 9900 Basement Window appear below.

How efficient is Wincore Window Company, LLC 7700, 9900 Basement Window compared with peer Window models?

Across 6,256 tested NFRC glazing configurations, Wincore Window Company, LLC 7700, 9900 Basement Window with Vinyl framing and Projected Awning (PRAW) style reaches a 0.17 minimum U-Factor and 0.08-0.41 SHGC band. It places #362 among 1,352 Window series—top 35.2%.

Is 7700, 9900 Basement Window approved for Northern Zone heating climates?

Yes, 416 packages satisfy Northern ENERGY STAR Version 7.0 rules in 7700, 9900 Basement Window. Pairing multi-pane insulation down to 0.17 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

What BTU/hr heat transfer results from 7700, 9900 Basement Window's 0.17 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 7700, 9900 Basement Window at U 0.17 conducts 102.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What are the practical limitations of specifying 7700, 9900 Basement Window?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 7700, 9900 Basement Window options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

How many 7700, 9900 Basement Window glazing packages pass Southern solar-heat rules?

Yes, 7700, 9900 Basement Window holds 5,928 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.08 SHGC in cooling climates.

Does 7700, 9900 Basement Window carry EPA Most Efficient certification across its lineup?

EPA lists 458 Most Efficient options (7.3% share) inside Wincore Window Company, LLC 7700, 9900 Basement Window, out of 6,256 total Version 7.0 entries.

Do 2026 7700, 9900 Basement Window installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 7700, 9900 Basement Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

Where are NFRC and IGCC identification marks located on 7700, 9900 Basement Window?

Confirm both the paper NFRC label and permanent corner glass etch match line WCW-M-38 and NFRC ID WCW before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Wincore Window Company, LLC 7700, 9900 Basement Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros