Skip to main content
Door · Other Frame NFRC WIN · Product Line WIN-N-136

Windsor Windows and Doors — Pinnacle Clad French & Narrow Sliding Door · Sliding Patio Door

Across 82 Windsor Windows and Doors certified families, Pinnacle Clad French & Narrow Sliding Door supplies 126 Sliding Patio Door configurations starting at 0.25 U-Factor and 0.12 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.28 U-Factor and 0.40 SHGC. Its thermal floor ranks #216 of 268 category entries—0.04 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.25
SHGC Range
0.12-0.40
Certified Options
126
Category Standing
#216 of 268

How does Windsor Windows and Doors Pinnacle Clad French & Narrow Sliding Door compare thermally against Door peers?

Windsor Windows and Doors Pinnacle Clad French & Narrow Sliding Door achieves a 0.25 thermal floor across Door lines, placing #216 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Pinnacle Clad French & Narrow Sliding DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Pinnacle Clad French & Narrow Sliding Door (U 0.25).28<=0.15650.16-0.18510.19-0.21710.22-0.24430.25-0.27This model: U 0.25100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Pinnacle Clad French & Narrow Sliding Door Cohort StandingMin U-Factor 0.25 stands at rank #216 of 268, outperforming 13.4% of peers.Min U-Factor 0.25Rank #216 of 268 (13.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Door assemblies nationwide (median U 0.21), Pinnacle Clad French & Narrow Sliding Door is 0.04 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median while keeping Other frame with Wood sash. Selecting different glass and gas-fill packages moves thermal performance along 0.25-0.28.

Climate coverage for Windsor Windows and Doors Pinnacle Clad French & Narrow Sliding Door spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 38 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.25 U-Factor yields 150.0 BTU/hr transfer (+18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-02-17 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 126 certified glazing combinations for Pinnacle Clad French & Narrow Sliding Door (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 38 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 38 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 120 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 120 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Pinnacle Clad French & Narrow Sliding Door appear below.

How efficient is Windsor Windows and Doors Pinnacle Clad French & Narrow Sliding Door compared with peer Door models?

Across 126 tested NFRC glazing configurations, Windsor Windows and Doors Pinnacle Clad French & Narrow Sliding Door with Other framing and Sliding Glass Door (DDSG) style reaches a 0.25 minimum U-Factor and 0.12-0.40 SHGC band. It places #216 among 268 Door series—more insulating than 13.4%.

How does Windsor Windows and Doors Pinnacle Clad French & Narrow Sliding Door satisfy Version 7.0 Northern criteria?

With a 0.25 minimum U-Factor, Windsor Windows and Doors Pinnacle Clad French & Narrow Sliding Door cannot satisfy prescriptive <= 0.22 Northern targets, yet 38 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.

How much winter heat loss does Pinnacle Clad French & Narrow Sliding Door conduct across a 15 sq ft opening?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Pinnacle Clad French & Narrow Sliding Door at U 0.25 conducts 150.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Who should NOT choose Windsor Windows and Doors Pinnacle Clad French & Narrow Sliding Door for a residential project?

Skip Pinnacle Clad French & Narrow Sliding Door if local historic preservation boards prohibit Other profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Pinnacle Clad French & Narrow Sliding Door options exceeding U 0.22.

How many Pinnacle Clad French & Narrow Sliding Door glazing packages pass Southern solar-heat rules?

Exactly 120 Pinnacle Clad French & Narrow Sliding Door options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.12 rather than higher 0.40 glass.

Are all 126 Pinnacle Clad French & Narrow Sliding Door configurations ENERGY STAR Most Efficient?

All 126 Pinnacle Clad French & Narrow Sliding Door listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

Can homeowners claim Form 5695 credits on Windsor Windows and Doors Pinnacle Clad French & Narrow Sliding Door in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Pinnacle Clad French & Narrow Sliding Door installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do you cross-check NFRC WIN and product line WIN-N-136 on delivery?

Match the NFRC thermal sticker for code WIN and line WIN-N-136 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Pinnacle Clad French & Narrow Sliding Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros