Windsor Windows and Doors — Pinnacle Primed Sliding French (Stationary Panel) · Swinging Entry Door (Single)
With a minimum U-Factor of 0.26—+0.05 compared against the 0.21 Door median—Windsor Windows and Doors Pinnacle Primed Sliding French (Stationary Panel) spans 60 tested options across Northern, North-Central, South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code WIN, the Other assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.11 and 0.16.
- Min U-Factor
- 0.26
- SHGC Range
- 0.11-0.16
- Certified Options
- 60
- Category Standing
- #233 of 268
How does Windsor Windows and Doors Pinnacle Primed Sliding French (Stationary Panel) compare thermally against Door peers?
Windsor Windows and Doors Pinnacle Primed Sliding French (Stationary Panel) achieves a 0.26 thermal floor across Door lines, placing #233 of 268 against the 0.21 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Glazing breadth across Pinnacle Primed Sliding French (Stationary Panel) spans 60 NFRC test records (WIN), ranking #233 of 268 Door families (tied with 15 others at 0.26, more insulating than 7.5% of Door lines). Its 0.26 thermal floor compares at +0.01 against the Other median (0.25).
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.26 floor sits above the 0.22 prescriptive Northern ceiling, 9 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.26 U-Factor yields 156.0 BTU/hr transfer (+24.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-02-17 certification.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 60 certified glazing combinations for Pinnacle Primed Sliding French (Stationary Panel) (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 9 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 9 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 60 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 60 packages (0 Most Eff.) |
Which competing Door series sit closest on U-Factor?
Inspect nearby Door competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Pella Corporation — Reserve Multi-Slide | Wood | 0.26 | 0.14 | 69 |
| Weather Shield Mfg., Inc. — 8511/1507 Inswing Door | Wood | 0.26 | 0.11 | 50 |
| ESWindows LLC — ES-LG850 | Aluminum | 0.26 | 0.12 | 101 |
| DRUTEX S.A. — MB-86 Fold Line HD Folding Door | Aluminum | 0.26 | 0.20 | 11 |
| Weather Shield Mfg., Inc. — 6510/6610 Swing Door | Wood | 0.26 | 0.11 | 207 |
What other certified series does Windsor Windows and Doors produce?
Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Pinnacle Clad Radius Direct Glaze
U-Factor 0.15–0.32 · 1,266 certified options.
Next Dimension Casement Picture
U-Factor 0.17–0.32 · 1,610 certified options.
Pinnacle Clad Direct Set 3.25" Frame
U-Factor 0.17–0.32 · 817 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Pinnacle Primed Sliding French (Stationary Panel) appear below.
Where does Windsor Windows and Doors Pinnacle Primed Sliding French (Stationary Panel) stand thermally among ENERGY STAR Door lines?
Built with Other framing in Entry Door Single-Lite (EDSL) style, Windsor Windows and Doors Pinnacle Primed Sliding French (Stationary Panel) offers 60 Version 7.0 configurations from U 0.26 up to 0.28, posting +0.05 against the Door median of 0.21 with 0 Most Efficient picks.
How does Windsor Windows and Doors Pinnacle Primed Sliding French (Stationary Panel) satisfy Version 7.0 Northern criteria?
Northern qualification on Pinnacle Primed Sliding French (Stationary Panel) relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.26. Exactly 9 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.
What BTU/hr heat transfer results from Pinnacle Primed Sliding French (Stationary Panel)'s 0.26 minimum U-Factor?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.26 U-Factor yields 156.0 BTU/hr conductive transfer (+18.2% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
When should a buyer skip Windsor Windows and Doors Pinnacle Primed Sliding French (Stationary Panel) and compare alternatives?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Pinnacle Primed Sliding French (Stationary Panel) options exceeding U 0.22. Verify whether your municipal code restricts Other frames in wildfire or historic zones.
Is Pinnacle Primed Sliding French (Stationary Panel) suitable for sunbelt cooling-dominated homes?
Exactly 60 Pinnacle Primed Sliding French (Stationary Panel) options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.11 rather than higher 0.16 glass.
What glazing share inside Pinnacle Primed Sliding French (Stationary Panel) qualifies as Most Efficient?
Pinnacle Primed Sliding French (Stationary Panel) holds zero Most Efficient entries across its 60 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.
Can homeowners claim Form 5695 credits on Windsor Windows and Doors Pinnacle Primed Sliding French (Stationary Panel) in 2026?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Pinnacle Primed Sliding French (Stationary Panel) retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
How do you cross-check NFRC WIN and product line WIN-N-138 on delivery?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code WIN and product line WIN-N-138, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Pinnacle Primed Sliding French (Stationary Panel) come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)