Skip to main content
Window · Wood Frame NFRC JEL · Product Line JEL-N-880

JELD-WEN, inc. — Siteline Clad Wood (W-5500) Double Hung · Double Hung

Positioning #1,256/1,352 in certified Window, JELD-WEN, inc. Siteline Clad Wood (W-5500) Double Hung pairs Wood frame construction with 1,292 glazing options rated between 0.11 and 0.23 SHGC across South-Central, Southern. Across 61 certified JELD-WEN, inc. product families, its thermal resistance spans 0.26 to 0.32 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.26
SHGC Range
0.11-0.23
Certified Options
1,292
Category Standing
#1,256 of 1,352

How does JELD-WEN, inc. Siteline Clad Wood (W-5500) Double Hung compare thermally against Window peers?

JELD-WEN, inc. Siteline Clad Wood (W-5500) Double Hung achieves a 0.26 thermal floor across Window lines, placing #1,256 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Siteline Clad Wood (W-5500) Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Siteline Clad Wood (W-5500) Double Hung (U 0.26).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.26310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Siteline Clad Wood (W-5500) Double Hung Cohort StandingMin U-Factor 0.26 stands at rank #1,256 of 1,352, outperforming 4.5% of peers.Min U-Factor 0.26Rank #1,256 of 1,352 (4.5% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows JELD-WEN, inc. Siteline Clad Wood (W-5500) Double Hung standing at #1,256 of 1,352 certified Window product series, tied with 35 others at 0.26, more insulating than 4.5% of Window lines. Comparing Wood profiles alone (median 0.21) shows +0.05 before selecting Low-E tiers.

Evaluating climate compliance across South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.11 lowers cooling load.

Data provenance links certification 2024-10-09 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 156.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,292 certified glazing combinations for Siteline Clad Wood (W-5500) Double Hung (NFRC JEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 138 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 1,292 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does JELD-WEN, inc. produce?

Compare other active JELD-WEN, inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to JELD-WEN, inc. Siteline Clad Wood (W-5500) Double Hung appear below.

What U-Factor and SHGC range does JELD-WEN, inc. Siteline Clad Wood (W-5500) Double Hung achieve?

Testing puts JELD-WEN, inc. Siteline Clad Wood (W-5500) Double Hung at rank #1,256 of 1,352 Window entries with U 0.26 to 0.32 across 1,292 configurations. Solar heat gain ranges between 0.11 and 0.23 across South-Central, Southern.

Which glazing options in JELD-WEN, inc. Siteline Clad Wood (W-5500) Double Hung meet Northern climate limits?

No. Because Siteline Clad Wood (W-5500) Double Hung reaches only 0.26 U-Factor with 0 Northern combinations, it is not approved for ENERGY STAR Northern counties. Specify this Wood line strictly across South-Central, Southern cooling or mixed markets.

How much winter heat loss does Siteline Clad Wood (W-5500) Double Hung conduct across a 15 sq ft opening?

Using NFRC JEL U-Factor 0.26, a 15 sq ft Double-Hung (VSDH) assembly conducts 156.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+24.0 BTU/hr margin).

What homeowner profiles are a poor match for JELD-WEN, inc. Siteline Clad Wood (W-5500) Double Hung?

Skip Siteline Clad Wood (W-5500) Double Hung if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Siteline Clad Wood (W-5500) Double Hung options exceeding U 0.22.

Can you install JELD-WEN, inc. Siteline Clad Wood (W-5500) Double Hung in Southern or South-Central zones?

Across South-Central, Southern, 1,292 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside JELD-WEN, inc. Siteline Clad Wood (W-5500) Double Hung, while total line SHGC reaches 0.23 in colder packages.

What glazing share inside Siteline Clad Wood (W-5500) Double Hung qualifies as Most Efficient?

Zero glazing builds inside Siteline Clad Wood (W-5500) Double Hung's 1,292 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

Do 2026 Siteline Clad Wood (W-5500) Double Hung installations qualify for IRS Section 25C tax credits?

Any Siteline Clad Wood (W-5500) Double Hung purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

What permanent glass etch marks verify Siteline Clad Wood (W-5500) Double Hung after sticker removal?

Verify NFRC ID JEL and series JEL-N-880 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for JELD-WEN, inc. Siteline Clad Wood (W-5500) Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros