Skip to main content
Window · Vinyl Frame NFRC MEI · Product Line MEI-A-219 ENERGY STAR Most Efficient Eligible

MI Windows and Doors, LLC — 1620/1621 Polyvinyl Chloride (PVC) Single Hung Window · Single Hung

With a minimum U-Factor of 0.20—At median compared against the 0.20 Window median—MI Windows and Doors, LLC 1620/1621 Polyvinyl Chloride (PVC) Single Hung Window spans 18,303 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code MEI, the Vinyl assembly includes 1,065 ENERGY STAR Most Efficient packages (5.8% of line) and offers SHGC packages between 0.08 and 0.51.

Min U-Factor
0.20
SHGC Range
0.08-0.51
Certified Options
18,303
Category Standing
#671 of 1,352

How does MI Windows and Doors, LLC 1620/1621 Polyvinyl Chloride (PVC) Single Hung Window compare thermally against Window peers?

MI Windows and Doors, LLC 1620/1621 Polyvinyl Chloride (PVC) Single Hung Window achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 1620/1621 Polyvinyl Chloride (PVC) Single Hung WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing 1620/1621 Polyvinyl Chloride (PVC) Single Hung Window (U 0.20).249<=0.153140.16-0.182670.19-0.21This model: U 0.203430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

1620/1621 Polyvinyl Chloride (PVC) Single Hung Window Cohort StandingMin U-Factor 0.20 stands at rank #671 of 1,352, outperforming 45.2% of peers.Min U-Factor 0.20Rank #671 of 1,352 (45.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 48 certified MI Windows and Doors, LLC series, this Single Hung offers a 0.12 U-Factor adjustment span between 0.32 entry options and 0.20 top-performing glazing. Category standing is #671/1,352 (tied with 70 others at 0.20, more insulating than 45.2% of Window lines).

Climate coverage for MI Windows and Doors, LLC 1620/1621 Polyvinyl Chloride (PVC) Single Hung Window spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 1,065 configurations meet ENERGY STAR Most Efficient criteria while 1,694 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 120.0 BTU/hr (-9.1% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-09-11 and cert timestamp 2026-07-23.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 18,303 certified glazing combinations for 1620/1621 Polyvinyl Chloride (PVC) Single Hung Window (NFRC MEI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 1,694 packages (16 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 6,950 packages (86 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 10,754 packages (79 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 15,322 packages (1,058 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Silver Line Building Products — 70 Series (West) Awning Window Vinyl 0.20 0.11 5,658
Quaker Window Products — V260/V300 Single Slider Vinyl 0.20 0.10 4,917
Quaker Window Products — V260 / V300 Single Hung Vinyl 0.20 0.10 4,887
Associated Materials, Inc. — A270/A570/S270/S570 Fixed Vinyl 0.20 0.09 2,471
DRUTEX S.A. — IGLO 5 Classic Transom Vinyl 0.20 0.04 2,381

What other certified series does MI Windows and Doors, LLC produce?

Compare other active MI Windows and Doors, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MI Windows and Doors, LLC 1620/1621 Polyvinyl Chloride (PVC) Single Hung Window appear below.

What thermal performance numbers separate MI Windows and Doors, LLC 1620/1621 Polyvinyl Chloride (PVC) Single Hung Window from peers?

Built with Vinyl framing in Single-Hung (VSSH) style, MI Windows and Doors, LLC 1620/1621 Polyvinyl Chloride (PVC) Single Hung Window offers 18,303 Version 7.0 configurations from U 0.20 up to 0.32, posting At median against the Window median of 0.20 with 1,065 Most Efficient picks.

Is 1620/1621 Polyvinyl Chloride (PVC) Single Hung Window approved for Northern Zone heating climates?

Yes. 1,694 packages in MI Windows and Doors, LLC 1620/1621 Polyvinyl Chloride (PVC) Single Hung Window clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

How much winter heat loss does 1620/1621 Polyvinyl Chloride (PVC) Single Hung Window conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.20 U-Factor yields 120.0 BTU/hr conductive transfer (-9.1% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Who should NOT choose MI Windows and Doors, LLC 1620/1621 Polyvinyl Chloride (PVC) Single Hung Window for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 1620/1621 Polyvinyl Chloride (PVC) Single Hung Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

How many 1620/1621 Polyvinyl Chloride (PVC) Single Hung Window glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 15,322 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside MI Windows and Doors, LLC 1620/1621 Polyvinyl Chloride (PVC) Single Hung Window, while total line SHGC reaches 0.51 in colder packages.

Which package tier in 1620/1621 Polyvinyl Chloride (PVC) Single Hung Window holds Most Efficient recognition?

EPA lists 1,065 Most Efficient options (5.8% share) inside MI Windows and Doors, LLC 1620/1621 Polyvinyl Chloride (PVC) Single Hung Window, out of 18,303 total Version 7.0 entries.

Do 2026 1620/1621 Polyvinyl Chloride (PVC) Single Hung Window installations qualify for IRS Section 25C tax credits?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 MI Windows and Doors, LLC upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

What permanent glass etch marks verify 1620/1621 Polyvinyl Chloride (PVC) Single Hung Window after sticker removal?

Match the NFRC thermal sticker for code MEI and line MEI-A-219 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for MI Windows and Doors, LLC 1620/1621 Polyvinyl Chloride (PVC) Single Hung Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros