MI Windows and Doors, LLC — 1650 Polyvinyl Chloride (PVC) Double Hung Window · Double Hung
MI Windows and Doors, LLC engineered the 1650 Polyvinyl Chloride (PVC) Double Hung Window Double Hung line for Northern, North-Central, South-Central, Southern, certifying 22,753 glass-spacer combinations from 0.16 to 0.32 U-Factor and 0.06 to 0.49 SHGC. Relative to other Vinyl models tracked under NFRC MEI, its minimum U-Factor is 0.03 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.16
- SHGC Range
- 0.06-0.49
- Certified Options
- 22,753
- Category Standing
- #250 of 1,352
How does MI Windows and Doors, LLC 1650 Polyvinyl Chloride (PVC) Double Hung Window compare thermally against Window peers?
MI Windows and Doors, LLC 1650 Polyvinyl Chloride (PVC) Double Hung Window achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places MI Windows and Doors, LLC 1650 Polyvinyl Chloride (PVC) Double Hung Window at rank #250 of 1,352 (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.06-0.49 band.
Mapping NFRC SHGC values (0.06 to 0.49) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 2,832 configurations meet ENERGY STAR Most Efficient criteria while 3,224 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Data provenance links certification 2024-02-29 and FENSTAR license 2018-09-11 inside EPA Version 7.0 tables. Heat transfer computes to 96.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 22,753 certified glazing combinations for 1650 Polyvinyl Chloride (PVC) Double Hung Window (NFRC MEI) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 3,224 packages (1,110 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 10,918 packages (2,095 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 14,967 packages (1,554 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 18,096 packages (2,167 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Ply Gem Window Group — Ply Gem 1500 Picture Window | Vinyl | 0.16 | 0.13 | 16,113 |
| JELD-WEN, inc. — JWC 6500 Vinyl Single Hung | Vinyl | 0.16 | 0.12 | 14,484 |
| JELD-WEN, inc. — JWC 6500 Vinyl Lift Out Horizontal Slider | Vinyl | 0.16 | 0.12 | 14,407 |
| Associated Materials, Inc. — A581/S581/A592 Single Hung | Vinyl | 0.16 | 0.06 | 14,368 |
| Harvey Industries, Inc. — Vinyl Casement Window | Vinyl | 0.16 | 0.15 | 12,695 |
What other certified series does MI Windows and Doors, LLC produce?
Compare other active MI Windows and Doors, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window
U-Factor 0.12–0.32 · 8,307 certified options.
9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window
U-Factor 0.13–0.32 · 6,920 certified options.
1615T Polyvinyl Chloride (PVC) Transom
U-Factor 0.14–0.31 · 3,234 certified options.
3075/3065 Direct Set Picture Window
U-Factor 0.14–0.32 · 35,308 certified options.
SR CASE PW Vinyl Fixed Window
U-Factor 0.14–0.31 · 5,254 certified options.
1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window
U-Factor 0.15–0.32 · 11,774 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MI Windows and Doors, LLC 1650 Polyvinyl Chloride (PVC) Double Hung Window appear below.
Where does MI Windows and Doors, LLC 1650 Polyvinyl Chloride (PVC) Double Hung Window stand thermally among ENERGY STAR Window lines?
Across 22,753 tested NFRC glazing configurations, MI Windows and Doors, LLC 1650 Polyvinyl Chloride (PVC) Double Hung Window with Vinyl framing and Double-Hung (VSDH) style reaches a 0.16 minimum U-Factor and 0.06-0.49 SHGC band. It places #250 among 1,352 Window series—top 26.7%.
Does MI Windows and Doors, LLC 1650 Polyvinyl Chloride (PVC) Double Hung Window qualify for the ENERGY STAR Northern Zone?
Yes, 3,224 packages satisfy Northern ENERGY STAR Version 7.0 rules in 1650 Polyvinyl Chloride (PVC) Double Hung Window. Pairing multi-pane insulation down to 0.16 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.
How much winter heat loss does 1650 Polyvinyl Chloride (PVC) Double Hung Window conduct across a 15 sq ft opening?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.16 U-Factor yields 96.0 BTU/hr conductive transfer (-27.3% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
Who should NOT choose MI Windows and Doors, LLC 1650 Polyvinyl Chloride (PVC) Double Hung Window for a residential project?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 1650 Polyvinyl Chloride (PVC) Double Hung Window options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.
How many 1650 Polyvinyl Chloride (PVC) Double Hung Window glazing packages pass Southern solar-heat rules?
Exactly 18,096 1650 Polyvinyl Chloride (PVC) Double Hung Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.06 rather than higher 0.49 glass.
Does 1650 Polyvinyl Chloride (PVC) Double Hung Window carry EPA Most Efficient certification across its lineup?
EPA lists 2,832 Most Efficient options (12.4% share) inside MI Windows and Doors, LLC 1650 Polyvinyl Chloride (PVC) Double Hung Window, out of 22,753 total Version 7.0 entries.
Do 2026 1650 Polyvinyl Chloride (PVC) Double Hung Window installations qualify for IRS Section 25C tax credits?
Any 1650 Polyvinyl Chloride (PVC) Double Hung Window purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
How do you cross-check NFRC MEI and product line MEI-A-216 on delivery?
Inspectors match the temporary NFRC sticker (U 0.16-0.32, SHGC 0.06-0.49) against permit drawings for line MEI-A-216. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for MI Windows and Doors, LLC 1650 Polyvinyl Chloride (PVC) Double Hung Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)