MI Windows and Doors, LLC — 1656 Polyvinyl Chloride (PVC) Double Hung Window · Double Hung
MI Windows and Doors, LLC 1656 Polyvinyl Chloride (PVC) Double Hung Window is a Double Hung assembly with a Vinyl frame that reaches a minimum U-Factor of 0.16 across 28,065 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #250 of 1,352 in Window, its thermal floor is 0.04 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.07 to 0.48.
- Min U-Factor
- 0.16
- SHGC Range
- 0.07-0.48
- Certified Options
- 28,065
- Category Standing
- #250 of 1,352
How does MI Windows and Doors, LLC 1656 Polyvinyl Chloride (PVC) Double Hung Window compare thermally against Window peers?
MI Windows and Doors, LLC 1656 Polyvinyl Chloride (PVC) Double Hung Window achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows MI Windows and Doors, LLC 1656 Polyvinyl Chloride (PVC) Double Hung Window standing at #250 of 1,352 certified Window product series, tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%. Comparing Vinyl profiles alone (median 0.19) shows -0.03 before selecting Low-E tiers.
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 3,637 configurations meet ENERGY STAR Most Efficient criteria while 2,721 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Lifecycle documentation anchors MEI to 2026-10-26 certification (FENSTAR issued 2018-09-11). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 96.0 BTU/hr conductive loss (-27.3% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 28,065 certified glazing combinations for 1656 Polyvinyl Chloride (PVC) Double Hung Window (NFRC MEI) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 2,721 packages (792 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 12,357 packages (2,347 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 19,446 packages (1,948 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 24,358 packages (3,167 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Ply Gem Window Group — Ply Gem 1500 Picture Window | Vinyl | 0.16 | 0.13 | 16,113 |
| JELD-WEN, inc. — JWC 6500 Vinyl Single Hung | Vinyl | 0.16 | 0.12 | 14,484 |
| JELD-WEN, inc. — JWC 6500 Vinyl Lift Out Horizontal Slider | Vinyl | 0.16 | 0.12 | 14,407 |
| Associated Materials, Inc. — A581/S581/A592 Single Hung | Vinyl | 0.16 | 0.06 | 14,368 |
| Harvey Industries, Inc. — Vinyl Casement Window | Vinyl | 0.16 | 0.15 | 12,695 |
What other certified series does MI Windows and Doors, LLC produce?
Compare other active MI Windows and Doors, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window
U-Factor 0.12–0.32 · 8,307 certified options.
9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window
U-Factor 0.13–0.32 · 6,920 certified options.
1615T Polyvinyl Chloride (PVC) Transom
U-Factor 0.14–0.31 · 3,234 certified options.
3075/3065 Direct Set Picture Window
U-Factor 0.14–0.32 · 35,308 certified options.
SR CASE PW Vinyl Fixed Window
U-Factor 0.14–0.31 · 5,254 certified options.
1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window
U-Factor 0.15–0.32 · 11,774 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MI Windows and Doors, LLC 1656 Polyvinyl Chloride (PVC) Double Hung Window appear below.
How well does 1656 Polyvinyl Chloride (PVC) Double Hung Window by MI Windows and Doors, LLC insulate relative to Window benchmarks?
MI Windows and Doors, LLC 1656 Polyvinyl Chloride (PVC) Double Hung Window spans 28,065 certified configurations with U-Factors between 0.16 and 0.32 and SHGC values from 0.07 to 0.48. Ranked #250 of 1,352 Window families, it carries 3,637 Most Efficient options.
Is 1656 Polyvinyl Chloride (PVC) Double Hung Window approved for Northern Zone heating climates?
Cold-climate buyers get 2,721 compliant Northern packages inside 1656 Polyvinyl Chloride (PVC) Double Hung Window, reaching down to U 0.16. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.
What conductive BTU/hr difference separates 1656 Polyvinyl Chloride (PVC) Double Hung Window from the 0.22 Northern rule?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.16 U-Factor yields 96.0 BTU/hr conductive transfer (-27.3% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
Who should NOT choose MI Windows and Doors, LLC 1656 Polyvinyl Chloride (PVC) Double Hung Window for a residential project?
Do not specify 1656 Polyvinyl Chloride (PVC) Double Hung Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 1656 Polyvinyl Chloride (PVC) Double Hung Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
How many 1656 Polyvinyl Chloride (PVC) Double Hung Window glazing packages pass Southern solar-heat rules?
Yes, 1656 Polyvinyl Chloride (PVC) Double Hung Window holds 24,358 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.07 SHGC in cooling climates.
What glazing share inside 1656 Polyvinyl Chloride (PVC) Double Hung Window qualifies as Most Efficient?
Only 3,637 options out of 28,065 (13.0%) meet tighter Most Efficient U-Factor and SHGC thresholds in MI Windows and Doors, LLC 1656 Polyvinyl Chloride (PVC) Double Hung Window, usually requiring triple-pane or upgraded Low-E coatings.
Do 2026 1656 Polyvinyl Chloride (PVC) Double Hung Window installations qualify for IRS Section 25C tax credits?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 MI Windows and Doors, LLC upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
How do building inspectors verify 1656 Polyvinyl Chloride (PVC) Double Hung Window glass specs on job sites?
Match the NFRC thermal sticker for code MEI and line MEI-A-274 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for MI Windows and Doors, LLC 1656 Polyvinyl Chloride (PVC) Double Hung Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)