Window · Vinyl Frame NFRC MEI · Product Line MEI-A-169 ENERGY STAR Most Efficient Eligible

MI Windows and Doors, LLC — 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window · Picture Window

Across 48 MI Windows and Doors, LLC certified families, 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window supplies 17,779 Picture Window configurations starting at 0.16 U-Factor and 0.09 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.55 SHGC. Its thermal floor ranks #250 of 1,352 category entries—0.04 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.16
SHGC Range
0.09-0.55
Certified Options
17,779
Category Standing
#250 of 1,352

How does MI Windows and Doors, LLC 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window compare thermally against Window peers?

MI Windows and Doors, LLC 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window (U 0.16).249<=0.153140.16-0.18This model: U 0.162670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window Cohort StandingMin U-Factor 0.16 stands at rank #250 of 1,352, outperforming 73.3% of peers.Min U-Factor 0.16Rank #250 of 1,352 (73.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window spans 17,779 NFRC test records (MEI), ranking #250 of 1,352 Window families (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%). Its 0.16 thermal floor compares at -0.03 against the Vinyl median (0.19).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 3,976 configurations meet ENERGY STAR Most Efficient criteria while 4,736 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.16 U-Factor yields 96.0 BTU/hr transfer (-36.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-09-11 licensing and 2024-02-29 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 17,779 certified glazing combinations for 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window (NFRC MEI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 4,736 packages (676 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 10,559 packages (1,655 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 10,714 packages (1,297 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 13,580 packages (3,460 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Ply Gem Window Group — Ply Gem 1500 Picture Window Vinyl 0.16 0.13 16,113
JELD-WEN, inc. — JWC 6500 Vinyl Single Hung Vinyl 0.16 0.12 14,484
JELD-WEN, inc. — JWC 6500 Vinyl Lift Out Horizontal Slider Vinyl 0.16 0.12 14,407
Associated Materials, Inc. — A581/S581/A592 Single Hung Vinyl 0.16 0.06 14,368
Harvey Industries, Inc. — Vinyl Casement Window Vinyl 0.16 0.15 12,695

What other certified series does MI Windows and Doors, LLC produce?

Compare other active MI Windows and Doors, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MI Windows and Doors, LLC 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window appear below.

How efficient is MI Windows and Doors, LLC 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window compared with peer Window models?

EPA ENERGY STAR v7.0 records 17,779 configurations for MI Windows and Doors, LLC 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window covering Northern, North-Central, South-Central, Southern, dropping down to U 0.16 versus a 0.20 Window median. Only 3,976 options earn Most Efficient status.

Does MI Windows and Doors, LLC 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window qualify for the ENERGY STAR Northern Zone?

MI Windows and Doors, LLC 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window supplies 4,736 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

What conductive BTU/hr difference separates 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window from the 0.22 Northern rule?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 96.0 BTU/hr on 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window's lowest-U package (0.16), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

When should a buyer skip MI Windows and Doors, LLC 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window suitable for sunbelt cooling-dominated homes?

Across Northern, North-Central, South-Central, Southern, 13,580 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside MI Windows and Doors, LLC 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window, while total line SHGC reaches 0.55 in colder packages.

Which package tier in 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window holds Most Efficient recognition?

Only 3,976 options out of 17,779 (22.4%) meet tighter Most Efficient U-Factor and SHGC thresholds in MI Windows and Doors, LLC 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window, usually requiring triple-pane or upgraded Low-E coatings.

Can homeowners claim Form 5695 credits on MI Windows and Doors, LLC 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window in 2026?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How can homeowners confirm delivered MI Windows and Doors, LLC 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window units match permits?

Verify NFRC ID MEI and series MEI-A-169 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for MI Windows and Doors, LLC 4300SP Polyvinyl Chloride (PVC) Fixed (Direct Set) Specialty Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros