Skip to main content
Window · Composite Frame NFRC AND · Product Line AND-N-97

Andersen Corporation — 100 Series/Series 2 Gliding Patio Door Sidelight · Sidelite

Positioning #1,292/1,352 in certified Window, Andersen Corporation 100 Series/Series 2 Gliding Patio Door Sidelight pairs Composite frame construction with 153 glazing options rated between 0.12 and 0.23 SHGC across South-Central, Southern. Across 111 certified Andersen Corporation product families, its thermal resistance spans 0.27 to 0.28 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.27
SHGC Range
0.12-0.23
Certified Options
153
Category Standing
#1,292 of 1,352

How does Andersen Corporation 100 Series/Series 2 Gliding Patio Door Sidelight compare thermally against Window peers?

Andersen Corporation 100 Series/Series 2 Gliding Patio Door Sidelight achieves a 0.27 thermal floor across Window lines, placing #1,292 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 100 Series/Series 2 Gliding Patio Door SidelightHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing 100 Series/Series 2 Gliding Patio Door Sidelight (U 0.27).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

100 Series/Series 2 Gliding Patio Door Sidelight Cohort StandingMin U-Factor 0.27 stands at rank #1,292 of 1,352, outperforming 2.4% of peers.Min U-Factor 0.27Rank #1,292 of 1,352 (2.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Composite cohort (0.22 median U-Factor), 100 Series/Series 2 Gliding Patio Door Sidelight reaches 0.27 on its lowest-conductivity package — #19 of 21 in Composite, tied with 1 other at 0.27, more insulating than 4.8% of Composite lines (+0.05 vs Composite peers). Pairing NFRC ID AND across multi-pane fills shifts U-Factor from 0.28 down toward 0.27.

Mapping NFRC SHGC values (0.12 to 0.23) against ENERGY STAR Version 7.0 targets approves South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.12 lowers cooling load.

Lifecycle documentation anchors AND to 2024-03-07 certification (FENSTAR issued 2019-01-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 162.0 BTU/hr conductive loss (+22.7% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 153 certified glazing combinations for 100 Series/Series 2 Gliding Patio Door Sidelight (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 153 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 153 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.27 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Custom Window Systems, Inc. — A-8450 Awning Vinyl 0.27 0.11 194
Custom Window Systems, Inc. — C-8400 Casement Vinyl 0.27 0.11 195
Weather Shield Mfg., Inc. — 8401 Horizontal Slider Wood 0.27 0.11 198
ViWinTech Window — Casement Vinyl 0.27 0.16 204
Windsor Windows and Doors — Revive Clad Pocket Double Hung Wood 0.27 0.11 241

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 100 Series/Series 2 Gliding Patio Door Sidelight appear below.

How well does 100 Series/Series 2 Gliding Patio Door Sidelight by Andersen Corporation insulate relative to Window benchmarks?

Testing puts Andersen Corporation 100 Series/Series 2 Gliding Patio Door Sidelight at rank #1,292 of 1,352 Window entries with U 0.27 to 0.28 across 153 configurations. Solar heat gain ranges between 0.12 and 0.23 across South-Central, Southern.

Does Andersen Corporation 100 Series/Series 2 Gliding Patio Door Sidelight qualify for the ENERGY STAR Northern Zone?

No—with 0 Northern packages and a 0.27 thermal floor, Andersen Corporation 100 Series/Series 2 Gliding Patio Door Sidelight targets warmer South-Central, Southern climates instead of cold Northern installations.

How do you calculate winter heat conduction for Andersen Corporation 100 Series/Series 2 Gliding Patio Door Sidelight?

Using NFRC AND U-Factor 0.27, a 15 sq ft Fixed Sidelite (FXSL) assembly conducts 162.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+30.0 BTU/hr margin).

What are the practical limitations of specifying 100 Series/Series 2 Gliding Patio Door Sidelight?

Do not specify 100 Series/Series 2 Gliding Patio Door Sidelight without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 100 Series/Series 2 Gliding Patio Door Sidelight options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Does 100 Series/Series 2 Gliding Patio Door Sidelight meet Southern hot-climate SHGC caps (<= 0.23)?

Yes, 100 Series/Series 2 Gliding Patio Door Sidelight holds 153 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.12 SHGC in cooling climates.

Which package tier in 100 Series/Series 2 Gliding Patio Door Sidelight holds Most Efficient recognition?

Zero glazing builds inside 100 Series/Series 2 Gliding Patio Door Sidelight's 153 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

Do 2026 100 Series/Series 2 Gliding Patio Door Sidelight installations qualify for IRS Section 25C tax credits?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do building inspectors verify 100 Series/Series 2 Gliding Patio Door Sidelight glass specs on job sites?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code AND and product line AND-N-97, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 100 Series/Series 2 Gliding Patio Door Sidelight come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros