Andersen Corporation — Residential Clad Entry Door Transom - Outswing; Sash-Set · Picture Window
With a minimum U-Factor of 0.17—-0.03 compared against the 0.20 Window median—Andersen Corporation Residential Clad Entry Door Transom - Outswing; Sash-Set spans 87,237 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code AND, the Wood assembly includes 4,268 ENERGY STAR Most Efficient packages (4.9% of line) and offers SHGC packages between 0.10 and 0.47.
- Min U-Factor
- 0.17
- SHGC Range
- 0.10-0.47
- Certified Options
- 87,237
- Category Standing
- #362 of 1,352
How does Andersen Corporation Residential Clad Entry Door Transom - Outswing; Sash-Set compare thermally against Window peers?
Andersen Corporation Residential Clad Entry Door Transom - Outswing; Sash-Set achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows Andersen Corporation Residential Clad Entry Door Transom - Outswing; Sash-Set standing at #362 of 1,352 certified Window product series, tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%. Comparing Wood profiles alone (median 0.21) shows -0.04 before selecting Low-E tiers.
Climate coverage for Andersen Corporation Residential Clad Entry Door Transom - Outswing; Sash-Set spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 4,268 configurations meet ENERGY STAR Most Efficient criteria while 3,633 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Lifecycle documentation anchors AND to 2025-03-12 certification (FENSTAR issued 2019-01-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 102.0 BTU/hr conductive loss (-22.7% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 87,237 certified glazing combinations for Residential Clad Entry Door Transom - Outswing; Sash-Set (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 3,633 packages (1,125 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 14,362 packages (2,225 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 25,093 packages (1,554 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 82,797 packages (3,587 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Ply Gem Window Group — Mira (2018) Casement Stationary | Wood | 0.17 | 0.12 | 14,893 |
| JELD-WEN, inc. — Siteline Clad Wood (W-5500) Casement | Wood | 0.17 | 0.00 | 9,709 |
| Marvin — Ultimate Outswing French Door Transom G2 | Wood | 0.17 | 0.10 | 7,857 |
| Weather Shield Mfg., Inc. — 8312 Flush Frame Direct Set | Wood | 0.17 | 0.13 | 4,388 |
| Pella Corporation — Pella Architect Clad Fixed Casement | Wood | 0.17 | 0.11 | 2,200 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation Residential Clad Entry Door Transom - Outswing; Sash-Set appear below.
How well does Residential Clad Entry Door Transom - Outswing; Sash-Set by Andersen Corporation insulate relative to Window benchmarks?
Andersen Corporation Residential Clad Entry Door Transom - Outswing; Sash-Set spans 87,237 certified configurations with U-Factors between 0.17 and 0.32 and SHGC values from 0.10 to 0.47. Ranked #362 of 1,352 Window families, it carries 4,268 Most Efficient options.
Does Andersen Corporation Residential Clad Entry Door Transom - Outswing; Sash-Set qualify for the ENERGY STAR Northern Zone?
Cold-climate buyers get 3,633 compliant Northern packages inside Residential Clad Entry Door Transom - Outswing; Sash-Set, reaching down to U 0.17. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.
What conductive BTU/hr difference separates Residential Clad Entry Door Transom - Outswing; Sash-Set from the 0.22 Northern rule?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.17 U-Factor yields 102.0 BTU/hr conductive transfer (-22.7% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
Which situations make Residential Clad Entry Door Transom - Outswing; Sash-Set the wrong window or door choice?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Residential Clad Entry Door Transom - Outswing; Sash-Set options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
How many Residential Clad Entry Door Transom - Outswing; Sash-Set glazing packages pass Southern solar-heat rules?
Yes, Residential Clad Entry Door Transom - Outswing; Sash-Set holds 82,797 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.10 SHGC in cooling climates.
Which package tier in Residential Clad Entry Door Transom - Outswing; Sash-Set holds Most Efficient recognition?
No. Exactly 4,268 of 87,237 configurations (4.9%) earn ENERGY STAR Most Efficient status in Residential Clad Entry Door Transom - Outswing; Sash-Set; the remaining standard v7.0 options pass base zone limits only.
What 2026 federal tax credit and Lead RRP rules apply to Residential Clad Entry Door Transom - Outswing; Sash-Set?
Any Residential Clad Entry Door Transom - Outswing; Sash-Set purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
How do you cross-check NFRC AND and product line AND-N-130 on delivery?
Confirm both the paper NFRC label and permanent corner glass etch match line AND-N-130 and NFRC ID AND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation Residential Clad Entry Door Transom - Outswing; Sash-Set come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)