Skip to main content
Window · Wood Frame NFRC AND · Product Line AND-N-130 ENERGY STAR Most Efficient Eligible

Andersen Corporation — Residential Clad Entry Door Transom - Outswing; Sash-Set · Picture Window

With a minimum U-Factor of 0.17—-0.03 compared against the 0.20 Window median—Andersen Corporation Residential Clad Entry Door Transom - Outswing; Sash-Set spans 87,237 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code AND, the Wood assembly includes 4,268 ENERGY STAR Most Efficient packages (4.9% of line) and offers SHGC packages between 0.10 and 0.47.

Min U-Factor
0.17
SHGC Range
0.10-0.47
Certified Options
87,237
Category Standing
#362 of 1,352

How does Andersen Corporation Residential Clad Entry Door Transom - Outswing; Sash-Set compare thermally against Window peers?

Andersen Corporation Residential Clad Entry Door Transom - Outswing; Sash-Set achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Residential Clad Entry Door Transom - Outswing; Sash-SetHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Residential Clad Entry Door Transom - Outswing; Sash-Set (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Residential Clad Entry Door Transom - Outswing; Sash-Set Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Andersen Corporation Residential Clad Entry Door Transom - Outswing; Sash-Set standing at #362 of 1,352 certified Window product series, tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%. Comparing Wood profiles alone (median 0.21) shows -0.04 before selecting Low-E tiers.

Climate coverage for Andersen Corporation Residential Clad Entry Door Transom - Outswing; Sash-Set spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 4,268 configurations meet ENERGY STAR Most Efficient criteria while 3,633 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors AND to 2025-03-12 certification (FENSTAR issued 2019-01-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 102.0 BTU/hr conductive loss (-22.7% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 87,237 certified glazing combinations for Residential Clad Entry Door Transom - Outswing; Sash-Set (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 3,633 packages (1,125 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 14,362 packages (2,225 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 25,093 packages (1,554 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 82,797 packages (3,587 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation Residential Clad Entry Door Transom - Outswing; Sash-Set appear below.

How well does Residential Clad Entry Door Transom - Outswing; Sash-Set by Andersen Corporation insulate relative to Window benchmarks?

Andersen Corporation Residential Clad Entry Door Transom - Outswing; Sash-Set spans 87,237 certified configurations with U-Factors between 0.17 and 0.32 and SHGC values from 0.10 to 0.47. Ranked #362 of 1,352 Window families, it carries 4,268 Most Efficient options.

Does Andersen Corporation Residential Clad Entry Door Transom - Outswing; Sash-Set qualify for the ENERGY STAR Northern Zone?

Cold-climate buyers get 3,633 compliant Northern packages inside Residential Clad Entry Door Transom - Outswing; Sash-Set, reaching down to U 0.17. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

What conductive BTU/hr difference separates Residential Clad Entry Door Transom - Outswing; Sash-Set from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.17 U-Factor yields 102.0 BTU/hr conductive transfer (-22.7% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Which situations make Residential Clad Entry Door Transom - Outswing; Sash-Set the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Residential Clad Entry Door Transom - Outswing; Sash-Set options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

How many Residential Clad Entry Door Transom - Outswing; Sash-Set glazing packages pass Southern solar-heat rules?

Yes, Residential Clad Entry Door Transom - Outswing; Sash-Set holds 82,797 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.10 SHGC in cooling climates.

Which package tier in Residential Clad Entry Door Transom - Outswing; Sash-Set holds Most Efficient recognition?

No. Exactly 4,268 of 87,237 configurations (4.9%) earn ENERGY STAR Most Efficient status in Residential Clad Entry Door Transom - Outswing; Sash-Set; the remaining standard v7.0 options pass base zone limits only.

What 2026 federal tax credit and Lead RRP rules apply to Residential Clad Entry Door Transom - Outswing; Sash-Set?

Any Residential Clad Entry Door Transom - Outswing; Sash-Set purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do you cross-check NFRC AND and product line AND-N-130 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line AND-N-130 and NFRC ID AND before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation Residential Clad Entry Door Transom - Outswing; Sash-Set come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros