MI Windows and Doors, LLC — 1620 Polyvinyl Chloride (PVC) Fixed Window · Picture Window
EPA ENERGY STAR Version 7.0 certifies 23,545 variants inside MI Windows and Doors, LLC 1620 Polyvinyl Chloride (PVC) Fixed Window, combining Vinyl frame construction with U-Factors spanning 0.17 to 0.32 and SHGC 0.09 to 0.55. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #362 of 1,352 among 1,352 Window families and posts 0.02 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.
- Min U-Factor
- 0.17
- SHGC Range
- 0.09-0.55
- Certified Options
- 23,545
- Category Standing
- #362 of 1,352
How does MI Windows and Doors, LLC 1620 Polyvinyl Chloride (PVC) Fixed Window compare thermally against Window peers?
MI Windows and Doors, LLC 1620 Polyvinyl Chloride (PVC) Fixed Window achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Glazing breadth across 1620 Polyvinyl Chloride (PVC) Fixed Window spans 23,545 NFRC test records (MEI), ranking #362 of 1,352 Window families (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%). Its 0.17 thermal floor compares at -0.02 against the Vinyl median (0.19).
Mapping NFRC SHGC values (0.09 to 0.55) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 4,364 configurations meet ENERGY STAR Most Efficient criteria while 5,897 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Data provenance links certification 2026-03-19 and FENSTAR license 2018-09-11 inside EPA Version 7.0 tables. Heat transfer computes to 102.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 23,545 certified glazing combinations for 1620 Polyvinyl Chloride (PVC) Fixed Window (NFRC MEI) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 5,897 packages (900 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 13,051 packages (1,901 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 13,019 packages (1,359 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 17,533 packages (3,630 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Simonton Building Products, Inc. - Simonton Windows — 325-325 Double Slider | Vinyl | 0.17 | 0.08 | 21,756 |
| PGT Industries — CA5440/5540 | Vinyl | 0.17 | 0.08 | 17,693 |
| PGT Industries — AW5440/5540 | Vinyl | 0.17 | 0.08 | 16,848 |
| Simonton Building Products, Inc. - Simonton Windows — 325-325 CA | Vinyl | 0.17 | 0.09 | 13,628 |
| Simonton Building Products, Inc. - Simonton Windows — 325-325 AW | Vinyl | 0.17 | 0.09 | 13,343 |
What other certified series does MI Windows and Doors, LLC produce?
Compare other active MI Windows and Doors, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window
U-Factor 0.12–0.32 · 8,307 certified options.
9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window
U-Factor 0.13–0.32 · 6,920 certified options.
1615T Polyvinyl Chloride (PVC) Transom
U-Factor 0.14–0.31 · 3,234 certified options.
3075/3065 Direct Set Picture Window
U-Factor 0.14–0.32 · 35,308 certified options.
SR CASE PW Vinyl Fixed Window
U-Factor 0.14–0.31 · 5,254 certified options.
1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window
U-Factor 0.15–0.32 · 11,774 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MI Windows and Doors, LLC 1620 Polyvinyl Chloride (PVC) Fixed Window appear below.
How efficient is MI Windows and Doors, LLC 1620 Polyvinyl Chloride (PVC) Fixed Window compared with peer Window models?
MI Windows and Doors, LLC 1620 Polyvinyl Chloride (PVC) Fixed Window spans 23,545 certified configurations with U-Factors between 0.17 and 0.32 and SHGC values from 0.09 to 0.55. Ranked #362 of 1,352 Window families, it carries 4,364 Most Efficient options.
Is 1620 Polyvinyl Chloride (PVC) Fixed Window approved for Northern Zone heating climates?
Yes. 5,897 packages in MI Windows and Doors, LLC 1620 Polyvinyl Chloride (PVC) Fixed Window clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.
What conductive BTU/hr difference separates 1620 Polyvinyl Chloride (PVC) Fixed Window from the 0.22 Northern rule?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.17 U-Factor yields 102.0 BTU/hr conductive transfer (-22.7% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
What homeowner profiles are a poor match for MI Windows and Doors, LLC 1620 Polyvinyl Chloride (PVC) Fixed Window?
Do not specify 1620 Polyvinyl Chloride (PVC) Fixed Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 1620 Polyvinyl Chloride (PVC) Fixed Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
Is 1620 Polyvinyl Chloride (PVC) Fixed Window suitable for sunbelt cooling-dominated homes?
Exactly 17,533 1620 Polyvinyl Chloride (PVC) Fixed Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.09 rather than higher 0.55 glass.
Are all 23,545 1620 Polyvinyl Chloride (PVC) Fixed Window configurations ENERGY STAR Most Efficient?
Only 4,364 options out of 23,545 (18.5%) meet tighter Most Efficient U-Factor and SHGC thresholds in MI Windows and Doors, LLC 1620 Polyvinyl Chloride (PVC) Fixed Window, usually requiring triple-pane or upgraded Low-E coatings.
How do the 25C sunset and pre-1978 Lead RRP rules affect 1620 Polyvinyl Chloride (PVC) Fixed Window?
IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 1620 Polyvinyl Chloride (PVC) Fixed Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.
Where are NFRC and IGCC identification marks located on 1620 Polyvinyl Chloride (PVC) Fixed Window?
Match the NFRC thermal sticker for code MEI and line MEI-A-220 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for MI Windows and Doors, LLC 1620 Polyvinyl Chloride (PVC) Fixed Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)