Skip to main content
Window · Vinyl Frame NFRC MEI · Product Line MEI-A-111 ENERGY STAR Most Efficient Eligible

MI Windows and Doors, LLC — 1655 Polyvinyl Chloride (PVC) Double Hung Window · Double Hung

EPA ENERGY STAR Version 7.0 certifies 5,731 variants inside MI Windows and Doors, LLC 1655 Polyvinyl Chloride (PVC) Double Hung Window, combining Vinyl frame construction with U-Factors spanning 0.16 to 0.32 and SHGC 0.06 to 0.49. Qualifying for Northern, North-Central, South-Central, Southern, this Double Hung family places #250 of 1,352 among 1,352 Window families and posts 0.03 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.16
SHGC Range
0.06-0.49
Certified Options
5,731
Category Standing
#250 of 1,352

How does MI Windows and Doors, LLC 1655 Polyvinyl Chloride (PVC) Double Hung Window compare thermally against Window peers?

MI Windows and Doors, LLC 1655 Polyvinyl Chloride (PVC) Double Hung Window achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 1655 Polyvinyl Chloride (PVC) Double Hung WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 1655 Polyvinyl Chloride (PVC) Double Hung Window (U 0.16).249<=0.153140.16-0.18This model: U 0.162670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

1655 Polyvinyl Chloride (PVC) Double Hung Window Cohort StandingMin U-Factor 0.16 stands at rank #250 of 1,352, outperforming 73.3% of peers.Min U-Factor 0.16Rank #250 of 1,352 (73.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), 1655 Polyvinyl Chloride (PVC) Double Hung Window reaches 0.16 on its lowest-conductivity package — #170 of 1,009 in Vinyl, tied with 100 others at 0.16, more insulating than 73.2% of Vinyl lines, top 26.8% (-0.03 vs Vinyl peers). Pairing NFRC ID MEI across multi-pane fills shifts U-Factor from 0.32 down toward 0.16.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 979 configurations meet ENERGY STAR Most Efficient criteria while 1,075 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 96.0 BTU/hr (-27.3% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-09-11 and cert timestamp 2024-02-29.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 5,731 certified glazing combinations for 1655 Polyvinyl Chloride (PVC) Double Hung Window (NFRC MEI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 1,075 packages (381 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 3,062 packages (718 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 3,615 packages (531 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 4,233 packages (747 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Great Day Improvements, LLC — 8200/820043 Horizontal Slider Vinyl 0.16 0.15 5,498
Vinylmax LLC — A4 Single Slider Vinyl 0.16 0.11 4,620
DRUTEX S.A. — IGLO ENERGY Classic Casement Vinyl 0.16 0.03 4,020
Vinylmax LLC — A4 Single Hung Vinyl 0.16 0.11 3,907
DRUTEX S.A. — IGLO ENERGY Classic Tilt Turn Vinyl 0.16 0.04 3,652

What other certified series does MI Windows and Doors, LLC produce?

Compare other active MI Windows and Doors, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MI Windows and Doors, LLC 1655 Polyvinyl Chloride (PVC) Double Hung Window appear below.

What U-Factor and SHGC range does MI Windows and Doors, LLC 1655 Polyvinyl Chloride (PVC) Double Hung Window achieve?

Built with Vinyl framing in Double-Hung (VSDH) style, MI Windows and Doors, LLC 1655 Polyvinyl Chloride (PVC) Double Hung Window offers 5,731 Version 7.0 configurations from U 0.16 up to 0.32, posting -0.04 against the Window median of 0.20 with 979 Most Efficient picks.

Does MI Windows and Doors, LLC 1655 Polyvinyl Chloride (PVC) Double Hung Window qualify for the ENERGY STAR Northern Zone?

Prescriptive Northern compliance covers 1,075 1655 Polyvinyl Chloride (PVC) Double Hung Window packages (U floor 0.16, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

What conductive BTU/hr difference separates 1655 Polyvinyl Chloride (PVC) Double Hung Window from the 0.22 Northern rule?

Using NFRC MEI U-Factor 0.16, a 15 sq ft Double-Hung (VSDH) assembly conducts 96.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-36.0 BTU/hr margin).

What homeowner profiles are a poor match for MI Windows and Doors, LLC 1655 Polyvinyl Chloride (PVC) Double Hung Window?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 1655 Polyvinyl Chloride (PVC) Double Hung Window options exceeding U 0.22. Additionally, do not order Double-Hung (VSDH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is 1655 Polyvinyl Chloride (PVC) Double Hung Window suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 4,233 Southern-approved options within 1655 Polyvinyl Chloride (PVC) Double Hung Window spanning SHGC down to 0.06. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

How many MI Windows and Doors, LLC 1655 Polyvinyl Chloride (PVC) Double Hung Window variants earn ENERGY STAR Most Efficient?

EPA lists 979 Most Efficient options (17.1% share) inside MI Windows and Doors, LLC 1655 Polyvinyl Chloride (PVC) Double Hung Window, out of 5,731 total Version 7.0 entries.

Can homeowners claim Form 5695 credits on MI Windows and Doors, LLC 1655 Polyvinyl Chloride (PVC) Double Hung Window in 2026?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 MI Windows and Doors, LLC upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do building inspectors verify 1655 Polyvinyl Chloride (PVC) Double Hung Window glass specs on job sites?

Confirm both the paper NFRC label and permanent corner glass etch match line MEI-A-111 and NFRC ID MEI before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for MI Windows and Doors, LLC 1655 Polyvinyl Chloride (PVC) Double Hung Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros