Kasson and Keller — 300B Double Hung · Double Hung

Positioning #831/1,352 in certified Window, Kasson and Keller 300B Double Hung pairs Vinyl frame construction with 185 glazing options rated between 0.19 and 0.49 SHGC across Northern, North-Central, South-Central, Southern. Across 14 certified Kasson and Keller product families, its thermal resistance spans 0.22 to 0.27 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.22
SHGC Range
0.19-0.49
Certified Options
185
Category Standing
#831 of 1,352

How does Kasson and Keller 300B Double Hung compare thermally against Window peers?

Kasson and Keller 300B Double Hung achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 300B Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 300B Double Hung (U 0.22).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.221460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

300B Double Hung Cohort StandingMin U-Factor 0.22 stands at rank #831 of 1,352, outperforming 30.8% of peers.Min U-Factor 0.22Rank #831 of 1,352 (30.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Kasson and Keller 300B Double Hung standing at #831 of 1,352 certified Window product series, tied with 104 others at 0.22, more insulating than 30.8% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.03 before selecting Low-E tiers.

Mapping NFRC SHGC values (0.19 to 0.49) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 68 combinations qualify in the Northern Zone alongside 64 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Registry history records EPA FENSTAR licensing on 2019-01-30 and v7.0 data certification on 2025-02-10. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.22 conducts 132.0 BTU/hr (matching the 0.22 Northern baseline).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 185 certified glazing combinations for 300B Double Hung (NFRC KKI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 68 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 99 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 64 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 64 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Kasson and Keller produce?

Compare other active Kasson and Keller certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kasson and Keller 300B Double Hung appear below.

How well does 300B Double Hung by Kasson and Keller insulate relative to Window benchmarks?

Kasson and Keller 300B Double Hung spans 185 certified configurations with U-Factors between 0.22 and 0.27 and SHGC values from 0.19 to 0.49. Ranked #831 of 1,352 Window families, it carries 0 Most Efficient options.

Is 300B Double Hung approved for Northern Zone heating climates?

Yes, 68 packages satisfy Northern ENERGY STAR Version 7.0 rules in 300B Double Hung. Pairing multi-pane insulation down to 0.22 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

What conductive BTU/hr difference separates 300B Double Hung from the 0.22 Northern rule?

At U 0.22, a standard 3x5 ft (15 sq ft) 300B Double Hung opening transfers 132.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +0.0 BTU/hr difference.

Who should NOT choose Kasson and Keller 300B Double Hung for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 300B Double Hung options exceeding U 0.22. Additionally, do not order Double-Hung (VSDH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

What Southern ENERGY STAR v7.0 options exist in 300B Double Hung?

Yes. 64 Southern-certified options inside Kasson and Keller 300B Double Hung satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.49 SHGC on west-facing glass to avoid excess afternoon solar gain.

Are all 185 300B Double Hung configurations ENERGY STAR Most Efficient?

300B Double Hung holds zero Most Efficient entries across its 185 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

Can homeowners claim Form 5695 credits on Kasson and Keller 300B Double Hung in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 300B Double Hung installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

Where are NFRC and IGCC identification marks located on 300B Double Hung?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code KKI and product line KKI-K-60, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kasson and Keller 300B Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros